During  the  warranty  and  guarantee  period,  service 

work and repairs may only be carried out by personnel 

authorised by the manufacturer.

 DANGER

Risk of fatal electric shock!

All electrical connection work must be 

carried out by qualified electricians only.

Before opening the unit, disconnect the 

system from the power supply - wait for 90 

seconds = residual voltage at inverter - and 

prevent it from being switched back on!

Existing  earthing  connections  within  housings  or  on 

mounting plates must not be altered. If this should ne-

vertheless be necessary in the course of repair or as-

sembly work:

 

► Restore earthing connections to their original con-

dition after completion of the work.

 WARNING

Only

  qualified  personnel  (trained  heating, 

refrigeration engineers and electricians) 

may carry out work on the unit and its 

components.

 WARNING

Unit contains refrigerant!

Leaking refrigerant could result in personal 

injury and environmental damage. 

Therefore:

 

● Switch off system.

 

● Notify  the  manufacturer’s  authorised  cus-

tomer service.

 IMPORTANT

For safety reasons:

Never  disconnect  the  unit  from  the  power 

supply, unless the unit is being opened.

 IMPORTANT

Install  the  heat  pump  only  outdoors  and 

operate  only  with  outside  air  as  the  heat 

source.  Do  not  restrict  or  block  the  air-

conducting sides.

  “Dimensioned  drawings”,  page 28,  and  “Instal-

lation plan”, page 29

 WARNING

Never  switch  on  the  unit  if  air  flow 

deflectors on the unit are removed.

 IMPORTANT

It is not permitted to integrate the heat pump 

in ventilation systems. Use of the cooled air 

for cooling purposes is not permitted.

 IMPORTANT

The ambient air at the place in which the heat 

pump is installed, as well as the air drawn in 

as a heat source, must not contain any corro-

sive constituents!

Constituents  (such  as  ammonia,  sulphur, 

chlorine,  salt,  sewage  gases,  flue  gases…) 

can  cause  damage  to  the  heat  pump, 

which  can  result  in  complete  failure  / 

irreparable  total  damage  to  the  heat  pump!

 

Can be installed near the coast.

 CAUTION!

In the air outlet area the air temperature 

is approx. 5° K below the ambient 

temperature. Under certain climatic 

conditions an ice layer can therefore form 

in the air outlet area. Install the heat pump 

so that the air blower does not discharge 

into footpath areas.

Decommissioning / draining the heating

If the system/heat pump is decommissioned or drained 

after  already  being  filled,  it  must  be  ensured  that 

the  condenser  and  any  heat  exchangers  have  been 

drained  completely  in  the  event  of  freezing  tempera-

tures.  Residual  water  in  heat  exchangers  and  con-

densers can result in damage to the components.
1.  Completely drain the system and the condenser, 

and open vent valves. 

2.  Blow them clear with compressed air, if required.

Contact

Addresses  for  purchasing  accessories,  for  servicing 

or  for  answers  to  questions  about  the  unit  and  this 

operating manual can be found on the internet and are 

kept up-to-date:

 

● Germany:  www.alpha-innotec.de

 

● EU: 

www.alpha-innotec.com

Содержание LW 161H-A

Страница 1: ...UK 83061500bUK Air Water Heat Pumps Outdoor installation Operating Manual LW 161H A V...

Страница 2: ...th the unit Treat all its constituent parts confidentially They are protected by copyright They may not be reproduced transmitted copied stored in electronic systems or translated into another languag...

Страница 3: ...ation pump 14 18 2 Circulation pump technical data 14 19 Buffer tank 14 20 Water heating 15 21 Hot water tank 15 22 Electrical connection work 15 22 1 Power connection 15 22 2 Heat pump side connectio...

Страница 4: ...nded for all users of the product The operation of the product via the heating and he at pump control and work on the product which is in tended for end customers operators is suitable for all age gro...

Страница 5: ...plan page 29 WARNING Never switch on the unit if air flow deflectors on the unit are removed IMPORTANT It is not permitted to integrate the heat pump in ventilation systems Use of the cooled air for c...

Страница 6: ...r the same technology only with reversed benefits The refrigerator extracts heat from food It discharges this heat into the room through fins at its rear The heat pump extracts heat from our environme...

Страница 7: ...the control element of the heating and heat pump controller to operate and control the heat pump system NOTE Make sure that the controller settings are correct Operating manual of the heating and heat...

Страница 8: ...f damage 2 Check to make sure that the delivery is complete Any defects or incorrect deliveries must be reported immediately NOTE Note the unit model Technical data Scope of supply page 26 Functionall...

Страница 9: ...sions of the heat pumps must be taken into account in the respective installation plans for air water heat pumps The respective regional regulations must be observed Installation site requirements 9 P...

Страница 10: ...ansport purposes IMPORTANT Do not tilt the unit by more than 45 maximum in any direction 16 2 Preparing for installation 1 Remove lower facing panels on the switch box side and the water connection si...

Страница 11: ...n nection side of the unit 1 1 To do this undo the two quick release screws in the lower facing panels 1 2 Pull each of the facing panels upwards and out wards lift them out of the unit frame and put...

Страница 12: ...has been fixed by the upper facing panels After removing the upper facing panels the top cover sits loosely on the top Lift off the unit cover and put it down in a safe place 4 Installing the air defl...

Страница 13: ...ANT Dirt and deposits in the existing hydraulic system can cause damage to the heat pump Ensure that a sludge separator is installed in the hydraulic system Rinse the hydraulic system thoroughly prior...

Страница 14: ...iten 1 senkrecht nach unten dr ckend Auslieferungszustand 2 senkrecht nach oben dr ckend Pumpengeh use um180 drehen 3 waagrecht nach oben dr cken Pumpengeh use um180 drehen 4 waagrecht nach untendr ck...

Страница 15: ...e baseplate and are routed through the cable duct and into the switch area 1 Cable duct 2 Opening in the baseplate 20 Water heating Water heating with the heat pump requires another heating water circ...

Страница 16: ...e engaged strain relief housing and push the strain relief housing approx 50cm over the load cable 50cm 6 2 Strip the load cable 55mm 55 mm 6 3 Shorten the live wires so that the PE conductor has a le...

Страница 17: ...is possible to select 6kW 4 kW 2 phase operation Disconnect Q5 6 for this Or 3 kW 2 kW 1 phase operation Disconnect Q5 6 and Q5 4 for this The values in brackets are for the 6 kW heating element Disc...

Страница 18: ...it can be disconnected and re connected after inserting the wires 4 2 Strip the bus cable 30 mm 30 mm 4 3 Push the shielding braid back 10 mm over the sheath 22 2 Heat pump side connection of the BUS...

Страница 19: ...he contact spring 4 12 Assemble the plug housing 4 13 Snap the wired plug into the lower part of the housing 4 14 Fit the strain relief and clip into place until the bus cable is clamped firmly IMPORT...

Страница 20: ...eizanlagen preventing damage in hot water heating systems Required pH value 8 2 10 for aluminium materials pH value 8 2 8 5 Fill the system with deionised heating water VE water or with water correspo...

Страница 21: ...ating is swit ched off A prerequisite is that the heat pump remains switched on and is not disconnected from the mains Should there be a risk of frost the circulation pumps are activated The following...

Страница 22: ...r integration of storage tank in series The IBN assistant already provides the option in the event of the integration of the storage tank in series to adjust the overflow valve according to to the hyd...

Страница 23: ...eck the condensate pan in the unit and the condensate drain regularly for dirt blockages and clean as necessary 26 Commissioning WARNING The unit may only be started up if the air deflector hoods are...

Страница 24: ...al cleaning agent any residues must be neu tralised and the system flushed intensive ly with water Always note and follow the technical data of the respective heat ex changer manufacturer 28 Malfuncti...

Страница 25: ...rants and oil according to the relevant regulations standards and guidelines 29 1 Removal of the buffer battery IMPORTANT Before scrapping the heating and heat pump controller remove the buffer batter...

Страница 26: ...Free pressing Pressure loss Flow rate bar bar l h 0 593 0 077 2000 Max allowable operating pressure bar 3 Circulation pump control range min I max l h 1000 2000 General unit data Total weight kg 315 W...

Страница 27: ...1 D ring 05 09 2014 823233a Datei 823233a Leistungs Druckverlustkurven LW 160H AV xls n nd d M M E Er rs st te el ll le er r D Da at tu um m Leistungs Druckverlustkurven PEP001 2013 D ring 25 03 2014...

Страница 28: ...er Austritt Vorlauf R 1 1 4 2 Heizwasser Eintritt R cklauf R 1 1 4 3 Kondensatschlauch Au en 36x3 4 Grundplatte LR Luftrichtung A B 4 3 2 1 A B C D E F 4 3 2 1 Zust nde Schutzvermerk ISO 16016 beachte...

Страница 29: ...1 a Zust PE PE Keys UK819377a All dimensions in mm Pos Name A Front view C Top view LR Air direction Minimum clearances 1 Recess in base 2 Local heat pipe for heating water forward return flow 3 Rese...

Страница 30: ...be ob served facing away from the coast prevailing wind direction 9 in a sheltered area near a wall 9 not in open areas 9 not in sandy surroundings to avoid the influx of sand on the seaward side 9 in...

Страница 31: ...31 Subject to change without notice 83061500bUK ait deutschland GmbH Row tank LW 161H A V...

Страница 32: ...32 Subject to change without notice 83061500bUK ait deutschland GmbH Separate buffer tank LW 161H A V 23 ZUP TRL G...

Страница 33: ...mfort board Expansion board 29 Dirt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge r o t a l u g e r e c n e r e f f i d e r u t a r e p m e T 7 1 l a n o i t p o g n i l o o c r o...

Страница 34: ...tor electric heating element hot water or buffer tank Plug power supply Plug Mod Bus Contactor for auxiliary heating Control signal of additional heat generator 2 alternative is general malfunction 3...

Страница 35: ...erminal in switch box heat pump 1 G1 E23 F6 PFC X10 3 M1 R6 F1 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 1 3 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 14 12 2017 AP 1N...

Страница 36: ...board Modbus Connecting cable Mod Bus J14 X10 K20 J20 STB Q6 J15 X20 X200 J22 J11 K22 J7 K23 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 2 3 3 4 5 6 7 AIT Stromlaufplan ait deutschland Gmb...

Страница 37: ...everse Flow sensor Heat source input sensor B10 817452b B11 J13 X100 R3 R2 R1 J21 R5 R4 SEC Board 1 2 3 4 5 6 7 8 1 2 8 A B C D E F Bl 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 14 1...

Страница 38: ...38 Subject to change without notice 83061500bUK ait deutschland GmbH...

Страница 39: ...39 Subject to change without notice 83061500bUK ait deutschland GmbH...

Страница 40: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf E info alpha innotec de W www alpha innotec de alpha innotec an ait deutschland GmbH brand UK...

Отзывы: