27
Subject to change without notice | 83050700fUK – Translation into English of the original German operating manual | ait-deutschland GmbH
WWC280X
— ı — ı •
• ı —
•
—
27,0 ı 5,1
—
—
27,0 ı 5,2
20 - 60
7 - 25
—
47
60
5300 ı 5300 ı 9300
0,18 ( —) ı 5300
—
Grundfos SP 8A-5
0,63
0,75 ı 2,3
2,40
6/4“
2300 ı 4600 ı 5800
—
0,4 ( —) ı 4600
2
365 (—)
—
—
R 6/4“ AG
R 6/4“ AG
R407c ı 4,4
3~/PE/400V/50Hz ı C20
1~/N/PE/230V/50Hz ı B10
— ı — ı —
5,29 ı 8,8 ı 0,86
14,8
— ı 29,5
20
— ı — ı —
0,22 ı n.n.
— ı —
—
• ı —
•
•
— ı — ı —
• ı 50l ı 1,5
•
• ı •
813238-e
Brine/water ı Air/water ı Water/water
• applicable ı — not applicable
Indoors ı Outdoors
• applicable ı — not applicable
Heating capacity/COP at
W10/W35
Standard point to EN14511
kW ı …
kW ı …
W10/W45
Standard point to EN14511
kW ı …
W10/W35
Standard point acc. to EN255
kW ı …
kW ı …
…
dB(A)
Flow rate: minimum flow ı nominal flow ı maximum flow
Pressure loss heat pump ∆p (with cooling ∆pK) ı Flow rate
bar (bar) ı l/h
Free compression heat pump ∆p (with cooling ∆pK) ı Flow rate
bar (bar) ı l/h
Power consumption of the heat source pump at nominal throughput
kW
kW ı A
Dirt trap, to be installed upstream of the heat pump (included in additional box)
Flow rate: minimum flow ı nominal flow ı maximum flow
Pressure loss heat pump ∆p (with cooling ∆pK) ı Flow rate
bar (bar) ı l/h
Free compression heat pump ∆p (with cooling ∆pK) ı Flow rate
bar (bar) ı l/h
Additional weight module 1
Additional weight module 2
…
…
Refrigerant type ı Quantity
… ı kg
Voltage code ı all-pole circuit breaker heat pump *)
… ı A
Voltage code ı circuit breaker control voltage *)
… ı A
Voltage code ı circuit breaker electric heating element *)
ı A
Effective power consumption in the standard point W10/W35 to EN14511: Power consumption ı current consumption ı cosφ
kW ı A ı …
Maximum machine current within the use limits
A
Starting current: direct ı with soft starter
A ı A
IP
Output, electric heating element 3 ı 2 ı 1 phase
kW ı kW ı kW
Circulation pump, heating circuit at nominal flow rate: Power consumption ı current consumption
kW ı A
Circulation pump, heat source at nominal flow rate: Power consumption ı current consumption
kW ı A
Specification only for units with designator K: Cooling output at nominal flow rate (15°C heat source, 25°C heating water)
kW
Safety component heating circuit ı Safety component heat source
Incl. in scope of delivery: • yes — no
Incl. in scope of delivery: • yes — no
integrated: • yes — no
Heat source: Scope of delivery ı Volume ı Initial pressure
• yes — no ı l ı bar
Heating circuit: Scope of delivery ı Volume ı Initial pressure
• yes — no ı l ı bar
integrated: • yes — no
Heating circuit ı heat source
Incl. in scope of delivery: • yes — no
UK813241-a
*) comply with local regulations n.d. = not detectable
WWC440X
— ı — ı •
• ı —
•
42,2 ı 5,3
21,3 ı 5,4
—
42,2 ı 5,4
21,3 ı 5,5
20 - 60
7 - 25
—
47
60
8500 ı 8500 ı 14700
0,35 ( —) ı 8500
—
Grundfos SP 8A-5
0,73
0,75 ı 2,3
2,0
6/4“
3600 ı 7200 ı 9000
—
0,44 ( —) ı 5200
2
402 (—)
—
—
R 6/4“ AG
R 6/4“ AG
R407c ı 8,4
3~/PE/400V/50Hz ı C32
1~/N/PE/230V/50Hz ı B10
— ı — ı —
2x 3,9 ı 2x 6,8 ı 0,83
2x 11,8
— ı 22
20
— ı — ı —
0,39 ı n.n.
— ı —
—
• ı —
•
•
— ı — ı —
• ı 80l ı 1,5
•
• ı •
813239-d