Domestic water heating
If the unit is to be used for domestic water heating, a
3-way changeover valve must be installed. This is not
included with the unit and must be ordered separately.
IMPORTANT
Only use the manufacturer’s original accessories.
Domestic water heating with the heat pump requires an
additional heating water circuit (parallel) to the heating
circuit. When connecting, make sure that the domestic
hot water charge is not fed through a buffer tank in the
heating circuit.
“Hydraulic connection” documents.
Domestic hot water tank
If the heat pump is to be used for domestic water heat-
ing, you must integrate special domestic hot water tanks
in the heat pump system. Choose a storage volume so
that the required quantity of domestic hot water is avail-
able even during a power failure.
NOTE:
The heat exchanger surface of the domestic hot
water tank must be dimensioned so that the
heating output of the heat pump is transferred
with minimum spread.
You can choose a domestic hot water tank from our
product range. They are optimally matched to your heat
pump.
NOTE:
Integrate the domestic hot water tank in the
heat pump system as shown in the hydraulic dia-
gram for your system.
“Hydraulic connection” documents.
Electrical connection work
The following applies to all work to be done:
DANGER!
Risk of fatal electric shock!
All electrical connection work must be
carried out by qualified electricians only.
Before opening the unit, safely disconnect
the system from the power supply and
prevent it from being switched back on!
WARNING!
During installation and when carrying out
electrical work, comply with the relevant
EN-, VDE and/or local safety regulations.
Comply with technical connection require-
ments of the responsible power supply
company (if required by the latter)!
NOTE.
All live cables must be stripped before they are
laid in the cable duct of the switchbox!
Open unit, if closed…
“Transport to the installation location”, and
.
Open electrical switchbox inside the unit…
1 Cover plate of the switchbox
2 Screw plugs