Operation
22
(06/2016)
Failure Information
The current failure information of the charge controller can be checked via the Failure Information page. A maximum of 15 failure
messages can be displayed. When the failures are eliminated, the corresponding failure information on the display will also be
eliminated.
Figure 18, Failure Information Screen
Table 11, List of Possible Failures
Failure Info
1. Over voltage
2. Over load
3. Short circuit
List of Possible Failures
Failure Information
Details
Load MOS-Short
The MOSFET load driver has been shorted.
Load Circuit
The load circuit has been shorted.
Load O. cur.
The load circuit is over current.
Input O. cur.
PV input is over current.
RPP Short
The reverse polarity protection MOSFET has been shorted.
RPP Break
The reverse polarity protecion MOSFET has been broken.
Char. MOS-Short
The charge driver MOSFET has been shorted.
Input O. cur.
The input is over current.
Disc. O.O.Ctrl.
Discharging is not being controlled.
Ctrler O.Temp.
The controller is over temperature.
Comm. Timeout
Communication has timed out between the OutBack Mate Micro and the charge controller.