INVERTER
900-0131-01-00 Rev A.vsd\INV Setup\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
Page 6
Setting up the basic Inverter
functions includes:
1. Selecting the AC input (Grid or Gen).
2. Setting the Search function.
SETUP/FX/INPUT
Ac1/grid 60.0 aac
limit
DOWN INC DEC PORT
SETUP/FX/SEARCH------P01
search 6
sensitivity
DOWN INC DEC PORT
SETUP/FX/SEARCH------P01
search 8 cycles
pulse length
DOWN INC DEC PORT
SETUP/FX/SEARCH------P01
search 60 cycles
pulse spacing
DOWN INC DEC PORT
SETUP/FX----------------
choose category
SRCH INPUT
SETUP------------------
choose device:
FX MATE
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
SETUP/FX/SEARCH---------
search setup completed
TOP SETUP MAIN
ADV/FX/PAGE1
choose category
ADV INV CHRG PG2
ADV/FX/INVERTER------P01
press button 2
Done
EXIT 1 2
ADV/FX/INVERTER------P01
press button 2
Ready
EXIT 1 2
ADV/FX/INVERTER------P01
press button 1
Ready
EXIT 1 2
ADV/FX/INVERTER------P01
choose fx port
then press next
EXIT PORT NEXT
ADV/FX/INVERTER---------
reset FX to factory
defaults
DOWN MORE
ADV/FX/INVERTER---------
inverter programming
completed
TOP ADV MAIN
ADV/FX/CHARGER-------P01
charger 12.0Aac
limit
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
charger 12.0 Aac
limit
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
absorb 28.8 Vdc
set point
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
absorb 1.0 hrs
time limit
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
float 27.2 Vdc
set point
DOWN INC DEC PORT
Continued on next page….
NOTE:
The values shown in this illustration
will vary depending on the model of inverter.
Setpoints:
Grid
Generator
1
ADV/FX/INVERTER-----P01
search 6
sensitivity
DOWN INC DEC PORT
ADV/FX/INVERTER-----P01
search 8
pulse length
DOWN INC DEC PORT
ADV/FX/INVERTER-----P01
search 8 cycles
pulse length
DOWN INC DEC PORT
ADV/FX/INVERTER------P01
search 60 cycles
pulse spacing
DOWN INC DEC PORT
ADV/FX/INVERTER------P01
low battery 21.0 Vdc
cutout set point
DOWN INC DEC PORT
ADV/FX/INVERTER------P01
low battery 25.0 Vdc
cutin set point
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
float 1.0 hrs
time limit
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
equalize 1.0 hrs
time limit
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
equalize 28.8 Vdc
set point
DOWN INC DEC PORT
ADV/FX/CHARGER-------P01
charger programming
completed
TOP ADV MAIN
Main Screen
ADV/FX/INVERTER------P01
adjust 120 Vac
output voltage
DOWN INC DEC PORT
Accessing the Advanced Menu:
ADV--------------------
choose device
FX CC DC MATE
Changing more detailed operating parameters
requires access to the Advanced Setup Menu.
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
Main Screen
Advanced Menu for Inverter
(Page 1 of 3)
ADV/FX/CHARGER-------P01
refloat 25.0 Vdc
set point
DOWN INC DEC PORT
Resetting the Inverter
to Factory Defaults
SETUP/FX/INPUT-------P01
ac transfer
control
DOWN GRID GEN PORT
1
SETUP/FX/INPUT
Ac2/gen 30.0 aac
limit
DOWN INC DEC PORT
SETUP/FX/INPUT---------
Input setup completed
TOP SETUP MAIN
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
ADV/SETTINGS/WARNING
changes made could
adversely affect
system performance
ADV/PASSOWRD------------
Enter the password
132
ENTER INC DEC EXIT
ADV/PASSOWRD------------
Enter the password
141
ENTER INC DEC EXIT
A
1. Press the <
INC
> soft key
until “
141
” is displayed on
the LCD.
2. Press the <
ENTER
> soft key
to accept the password and
move forward to the Device
Selection Menu.
A
B
B
To return to the Main
screen at any time:
MAIN-------------------
3:02:14P
SUM STATUS SETUP ADV
Press and hold the 2 left soft
keys at the same time. Release
when the Main screen appears.
Содержание Out Back Power MATE Series
Страница 1: ...System Display and Controller ...
Страница 14: ...1 3 0 0 1 9 1 9 1 1 ...