Alpha Boilers Alpha CD24C Скачать руководство пользователя страница 5

Supplied By www.heating spares.co  Tel. 0161 620 6677

5

Alpha CD24/32

Thermostatic or pressure equalising type - When using these types of shower set the boiler domestic hot water thermostat
to maximum. The shower should then maintain a relatively constant temperature.

Manual bath mixer type shower - When using this type of shower set the boiler domestic hot water thermostat to setting 7,
This should avoid excessive temperatures at the shower.
Note: If you get unacceptable temperature variations with this type of shower, then a thermostatic or pressure equalising type
should be used.

1. BOILER LOCATION

Always ensure the following clearances are available around the casing of the boiler (not including the bottom tray):-

Top: 220 mm, Bottom: 250 mm, Each side: 5 mm, Front: 450 mm

Do not store any other articles in the cupboard containing the boiler and never place any clothing or combustible material on or near
the boiler or flue pipe.

2. FLUE TERMINAL

The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and
contact your Service Engineer.

Note: The Alpha CD boilers are high efficiency condensing boilers and when operating vapour will be emitted from the
terminal. This is safe and quite normal.

3. MAINS FAILURE

In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal
operation. Remember to reset the clock, if fitted, when the supply is restored.
CD24C - If the mains water supply fails, there will be no hot water from the taps. The boiler will continue to provide central heating.

4. ADDITIONAL BATHROOM FITTINGS - CD24C and CD32C only

Any equipment such as mixing valves, showers, bidets etc. must be designed to operate at mains water pressure. Contact your
plumbing merchant or installer for advice when considering purchasing such items.

5. CLEANING

Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners.

6. SERVICING

To maintain efficient and safe operation of your boiler, routine annual servicing is essential.
For advice on servicing contact:- The Alpha Helpline: 01322 669443.

7. GAS LEAK

If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish all
naked flames. Contact your local Gas Region immediately.

8. ELECTRICAL SUPPLY

The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug is used.

To connect a plug:-

The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals
in your plug. In this case proceed as follows:-

The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the
earth symbol 

, or coloured green or green and yellow.

The blue wire must be connected to the terminal which is marked with either the letter N or coloured black.
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.

THE APPLIANCE MUST BE EARTHED.

8

IMPORTANT NOTES

7

USING A SHOWER - CD24C and CD32C Only

Содержание Alpha CD24C

Страница 1: ...p or for Service call ALPHA HELPLINE Tel 01322 669443 Alpha CD24 32 Range of Wall Mounted Fan Assisted Room Sealed Gas Fired High Efficiency Condensing Boilers Alpha CD24C G C No 47 532 19 Alpha CD24S...

Страница 2: ...ting as required during the on times set on your clock if fitted Hot water is always available from the Alpha CD24C and CD32C boilers whenever a hot tap is opened and takes priority over the central h...

Страница 3: ...nated the following conditions apply Neon D Illuminated continuously Electricity supply to the boiler is on C Illuminated continuously Burner is alight A Flashing on and off Temperature sensor fault c...

Страница 4: ...r automatically until the temperature of the water in the heating system has been raised To turn the boiler off for longer periods Switch off the electrical supply to the boiler If required all suppli...

Страница 5: ...24C If the mains water supply fails there will be no hot water from the taps The boiler will continue to provide central heating 4 ADDITIONAL BATHROOM FITTINGS CD24C and CD32C only Any equipment such...