Alpha CD24/32

1. CENTRAL HEATING THERMOSTAT

This thermostat controls the temperature of the water leaving the boiler for the heating system. For maximum output from the
radiators the thermostat should be left at maximum i.e. fully clockwise. If lower heating temperatures are required, turn the thermostat
anti-clockwise.

2. DOMESTIC HOT WATER THERMOSTAT - CD24C and CD32C only

This thermostat controls the temperature of the domestic hot water leaving the boiler. For maximum hot water temperatures the
thermostat should be left at maximum i.e. fully clockwise. If lower temperatures are required, turn the thermostat anti-clockwise.

3. SELECTOR SWITCH

This control allows the boiler to provide central heating and, if applicable (CD24C and CD32C), hot water or hot water only.
CD24C and CD32C only - Note: The internal clock and frost thermostat will not operate when the switch is in the vertical
position, i.e. 'Off' position (0).

4. PRESSURE GAUGE

This indicates the central heating system pressure. It should always be within the green band when cold, increasing slightly
when hot.
If the pressure falls below the green band, i.e. lower red area, refer to the label on the inside of the hinged control panel cover
(not applicable for CD24S) for guidance on re-pressurising the system. Or contact your Installer to have the system checked
and pressurised.

5. INDICATOR NEONS

When neons A (red), B (red), C (yellow), D (green) are illuminated, the following conditions apply:-

Neon

D

Illuminated continuously - Electricity supply to the boiler is on.

C

Illuminated continuously - Burner is alight.

A

Flashing on and off - Temperature sensor fault, contact your Service Engineer.

B

Flashing on and off - Overheat thermostat has operated. Rotate selector switch to the reset position (3) to reset. If this continues
to happen, contact yor Service Engineer.

B

Illuminated continuously - Burner has failed to light. Rotate selector switch to the reset position (3) and the ignition
sequence will restart after a delay of about 30 seconds.

A and Flashing on and off at the same time - Blocked flue or fan fault, contact your Service Engineer.

A and Flashing on and off alternatively - System pressure is very low and re-pressurisation is required.

6. OVERHEAT THERMOSTAT

This thermostat automatically switches the boiler off in the unlikely event of the boiler overheating. When the thermostat operates,
the red neon (B) flashes on and off. Rotate the selector switch to the reset position (3) and the boiler will relight.
If this continually happens, contact your Service Engineer.

7. PRESSURE RELIEF VALVE

If the central heating system overheats and steam or water is discharged from the pipe connected to this valve, turn the boiler off
and contact your Service Engineer. Your Installer should have shown you where this pipe terminates, usually outside your dwelling.

8. FROST THERMOSTAT

The boiler has a built-in frost thermostat, which automatically operates the boiler if the water temperature falls below 4°C,
providing the electrical supply is on and the selector switch is set to position (1) or position (2).

3

BOILER CONTROLS

Содержание Alpha CD24C

Страница 1: ...p or for Service call ALPHA HELPLINE Tel 01322 669443 Alpha CD24 32 Range of Wall Mounted Fan Assisted Room Sealed Gas Fired High Efficiency Condensing Boilers Alpha CD24C G C No 47 532 19 Alpha CD24S...

Страница 2: ...ting as required during the on times set on your clock if fitted Hot water is always available from the Alpha CD24C and CD32C boilers whenever a hot tap is opened and takes priority over the central h...

Страница 3: ...nated the following conditions apply Neon D Illuminated continuously Electricity supply to the boiler is on C Illuminated continuously Burner is alight A Flashing on and off Temperature sensor fault c...

Страница 4: ...r automatically until the temperature of the water in the heating system has been raised To turn the boiler off for longer periods Switch off the electrical supply to the boiler If required all suppli...

Страница 5: ...24C If the mains water supply fails there will be no hot water from the taps The boiler will continue to provide central heating 4 ADDITIONAL BATHROOM FITTINGS CD24C and CD32C only Any equipment such...

Страница 6: ...al heating Log Book You can check your installer is CORGI registered by calling CORGI on 01256 372300 The clock allows you to set the times at which the boiler will operate to provide central heating...

Страница 7: ...when you ring The Serial No of the boiler is on the inside of the hinged cover or underneath the control panel 0 1 2 3 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 bar 0 4 3 2 1 RESET A D B C SELECTOR THERMOST...

Страница 8: ...Therm Limited Goldsel Road Swanley Kent BR8 8EX Tel 01322 669443 Fax 01322 615017 email info alphatherm co uk website www alpha boilers com Part No 1 019478 These instructions have been carefully pre...

Отзывы: