NOTICE
Penetration of moisture into the device
Device damage.
Make sure when carrying out cleaning and maintenance work that no moisture
penetrates the inside of the device.
7.2
Cleaning the enclosure
Clean the outside of the enclosure with the inscriptions and the display window using a cloth
moistened with water or a mild detergent.
Do not use any aggressive cleansing agents or solvents, e.g. acetone. Plastic parts or the painted
surface could be damaged. The inscriptions could become unreadable.
WARNING
Electrostatic charge
Risk of explosion in hazardous areas if electrostatic charges develop, for example, when cleaning
plastic surfaces with a
dry cloth.
Prevent electrostatic charging in hazardous areas.
7.3
Battery replacement
An empty battery in the Aloxy Pulse can be replaced by a fully charged one.
USE ONLY THE FOLLOWING BATTERIES ON THE ALOXY PULSE v01:
ALOXY partnumber:
T36851CCC
ALOXY partnumber:
E36850CCC
To do so, the Aloxy Pulse device must be opened to access the battery compartment.
Remove the Aloxy Pulse device from its mounting bracket as described in section 6.1 (step 3) and
bring it to a workshop area.
WARNING
Do not open the Aloxy Pulse in the field or within an hazardous (classified) area to replace the
battery. The device can only be opened in a workshop equipped to handle electronic
components.
To open the Aloxy Pulse, put the device upside-down on a workbench and remove the 4 screws
counter-clockwise from the screw holes using a Torx (6-point star-shaped) T10 screwdriver.