The Alnor AVM430/Airflow Instruments TA430 requires very little 
maintenance to keep it performing well.  

Recalibration 

To maintain a high degree of accuracy in your measurements, we 
recommend that you return your Alnor AVM430/Airflow Instruments 
TA430 to 

TSI for annual recalibration. Please contact one of TSI’s 

offices or your local distributor to make service arrangements and to 
receive a Return Material Authorization (RMA) number. To fill out an 
online RMA form, visit TSI’s website at 

http://service.tsi.com

.  

 

U.S. & International 

UK 

TSI Incorporated 

TSI Instruments Ltd

Alnor Products 

Stirling Road 

500 Cardigan Road 

Cressex Business Park 

Shoreview  MN  55126-3996 

High Wycombe 

Tel:  (800) 874-2811

 

Bucks  

 

(651) 490-2811 

HP12 3ST United Kingdom 

Fax: (651) 490-3824 

Tel:  +44 (0) 149 4 459200 

 

Fax:  +44 (0) 149 4 459700 

 
The Alnor AVM430/Airflow Instruments TA430 can also be 
recalibrated in the field using the CALIBRATION menu. These field 
adjustments are intended to make minor changes in calibration to 
match a user's calibration standards. The field adjustment is 

NOT

 

intended as a complete calibration capability. For complete, multiple-
point calibration and certification, the instrument must be returned to 
the factory. 

Cases 

If the instrument case or storage case needs cleaning, wipe it off with 
a soft cloth and isopropyl alcohol or a mild detergent. Never immerse 
the Alnor AVM430/Airflow Instruments TA430. If the enclosure of the 
Alnor AVM430/Airflow Instruments TA430 or the AC adapter 
becomes broken, it must be replaced immediately to prevent access 
to hazardous voltage. 

Storage 

Remove the batteries when storing the unit for more than one month 
to prevent damage due to battery leakage. 

www.

.com

[email protected]

1.800.561.8187

Содержание AIRFLOW TA430

Страница 1: ...AIR VELOCITY METER ALNOR MODEL AVM430 AVM430A AIRFLOW INSTRUMENTS MODEL TA430 TA430A OPERATION AND SERVICE MANUAL P N 1980583 REV F SEPTEMBER 2014 www com information itm com 1 800 561 8187...

Страница 2: ...loss and will be returned if at all at Seller s risk of loss Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limite...

Страница 3: ...nding the Probe 3 Retracting the Probe 3 Connecting to a Computer 4 CHAPTER 3 OPERATION 5 Keypad Functions 5 Common Terms 5 Menus 6 DISPLAY SETUP 6 SETTINGS 6 FLOW SET UP 6 ACTUAL STANDARD SETUP 6 DAT...

Страница 4: ...sure to provide the correct voltage and frequency which is marked on the back of the AC adapter The AC adapter will not recharge the batteries Using the Telescoping Probe The telescoping probe contai...

Страница 5: ...d data For more information on how to download stored data see Chapter 3 section titled LogDat2 Downloading Software C a u t i o n This symbol is used to indicate that the data port of the Alnor AVM43...

Страница 6: ...used in different places The following is a brief explanation of the meanings of those terms Sample Consists of all of the measurement parameters stored at the same time Test ID A group of samples The...

Страница 7: ...4 types Round Duct Rectangle Duct Duct Area and Horn Use the or soft keys to scroll through the types and then press the key to accept the desired type To change the value highlight the Enter Settings...

Страница 8: ...ruments TA430 comes with special software called LogDat2 Downloading Software which is designed to provide you with maximum flexibility and power To install this software on your computer follow the i...

Страница 9: ...3824 Tel 44 0 149 4 459200 Fax 44 0 149 4 459700 The Alnor AVM430 Airflow Instruments TA430 can also be recalibrated in the field using the CALIBRATION menu These field adjustments are intended to mak...

Страница 10: ...atteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less turbulent flow or use longer time consta...

Страница 11: ...Resolution 0 1 F 0 1 C Instrument Temperature Range Operating Electronics 40 to 113 F 5 to 45 C Operating Probe 0 to 200 F 18 to 93 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Alti...

Страница 12: ...6 lbs 0 27 kg Power Requirements Four AA size batteries included or AC adapter optional 9 VDC 300 mA min 1 Temperature compensated over an air temperature range of 40 to 150 F 5 to 65 C 2 The accurac...

Отзывы: