Alnor AIRFLOW TA430 Скачать руководство пользователя страница 2

ii

 

REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL 
REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL 
REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL 
SELLER BE LIABLE FOR LOST PROFITS, BUSINESS INTERRUPTION, OR ANY 
SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER 
SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR 
REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be 
brought against Seller more than 12 months after a cause of action has accrued. The 
goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and 
will be returned, if at all, at Seller's risk of loss. 

Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY 
AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. 
This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or 
its terms waived, except by writing signed by an Officer of Seller. 

Service Policy 

Knowing that inoperative or defective instruments are as detrimental to TSI as they are 
to our customers, our service policy is designed to give prompt attention to any 
problems. If any malfunction is discovered, please contact your nearest sales office or 
representative, or call Customer Service department at +44 (0) 149 4 459200 (UK), 
(800) 874-2811 (USA), or (1) 651-490-2811 (International). 

 

www.

.com

[email protected]

1.800.561.8187

Содержание AIRFLOW TA430

Страница 1: ...AIR VELOCITY METER ALNOR MODEL AVM430 AVM430A AIRFLOW INSTRUMENTS MODEL TA430 TA430A OPERATION AND SERVICE MANUAL P N 1980583 REV F SEPTEMBER 2014 www com information itm com 1 800 561 8187...

Страница 2: ...loss and will be returned if at all at Seller s risk of loss Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limite...

Страница 3: ...nding the Probe 3 Retracting the Probe 3 Connecting to a Computer 4 CHAPTER 3 OPERATION 5 Keypad Functions 5 Common Terms 5 Menus 6 DISPLAY SETUP 6 SETTINGS 6 FLOW SET UP 6 ACTUAL STANDARD SETUP 6 DAT...

Страница 4: ...sure to provide the correct voltage and frequency which is marked on the back of the AC adapter The AC adapter will not recharge the batteries Using the Telescoping Probe The telescoping probe contai...

Страница 5: ...d data For more information on how to download stored data see Chapter 3 section titled LogDat2 Downloading Software C a u t i o n This symbol is used to indicate that the data port of the Alnor AVM43...

Страница 6: ...used in different places The following is a brief explanation of the meanings of those terms Sample Consists of all of the measurement parameters stored at the same time Test ID A group of samples The...

Страница 7: ...4 types Round Duct Rectangle Duct Duct Area and Horn Use the or soft keys to scroll through the types and then press the key to accept the desired type To change the value highlight the Enter Settings...

Страница 8: ...ruments TA430 comes with special software called LogDat2 Downloading Software which is designed to provide you with maximum flexibility and power To install this software on your computer follow the i...

Страница 9: ...3824 Tel 44 0 149 4 459200 Fax 44 0 149 4 459700 The Alnor AVM430 Airflow Instruments TA430 can also be recalibrated in the field using the CALIBRATION menu These field adjustments are intended to mak...

Страница 10: ...atteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less turbulent flow or use longer time consta...

Страница 11: ...Resolution 0 1 F 0 1 C Instrument Temperature Range Operating Electronics 40 to 113 F 5 to 45 C Operating Probe 0 to 200 F 18 to 93 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Alti...

Страница 12: ...6 lbs 0 27 kg Power Requirements Four AA size batteries included or AC adapter optional 9 VDC 300 mA min 1 Temperature compensated over an air temperature range of 40 to 150 F 5 to 65 C 2 The accurac...

Отзывы: