13. TESTING THE SAUNA HEATER

 

Turn the temperature control to the desired setting.  Generally the heater will be operated with the tempera-
ture control to the “max” setting. Turn the heater “on” according to the TIMER OPERATION instructions on 
the previous page. Within 5 minutes you should be able to feel heat from the heater elements when holding 
your hand over the heater.  (If heater does not heat, refer to troubleshooting information on the following 
page.) Be sure to let the sauna heat for at least one hour before using the sauna. 

11.

 Mount the metal temp sensor 

housing vertically on the wall and 
12” to the right or left of the heat-
er. 

For barrel-shaped saunas: 

Mount the housing so that the top 
is 4.5” below the upper horizontal 
wall support. 

For a box-shaped 

saunas:

 Mount the housing 15” 

down from the ceiling. 

12. 

Conceal the temp sensor by 

mounting the sensor cover.  Place 
the cover over the temp sensor 
and mount with a single screw that 
is provided.  Carefully position the 
trim over the sensor cable so that 
the cable is concealed within the 
groove of the trim piece.  Attach 
trim to wall with included finish 
nails. 

Sensor Cover 