6.
Find the wire opening slot
and place the coated portion
of the sensor wire through
the slot. This will allow the
sensor to be placed on the
back wall of the sauna.
7.
Wire the heater according
to the diagram. All wiring
should be done by a licensed
electrician. Replace bottom
cover once wiring is com-
plete.
8.
Mount the heater with screws
provided so that the bottom of
the heater is 7” from the lowest
point of the sauna room floor.
Install the heater fence below
the level of the sauna stones.
Heater Fence
3.
The temp sensor housing is
attached to the heater element
with a zip tie. Clip the zip tie
and remove the sensor hous-
ing from the heater. Set aside
the temp sensor housing for
now.
4.
Turn the heater on it’s back and
remove the bottom cover to ex-
pose the temp sensor.
5.
Remove the temp sensor and
carefully uncoil the sensor cable
that is attached to the sensor.
Temp Sensor
Temp Sensor
Sensor Cable