Almax Air Patrol 90L Скачать руководство пользователя страница 4

OPERATING INSTRUCTIONS

1.  Attach the clear discharge tube (5 metres supplied) to the outlet by 

removing the nut and sliding it back over the tubing. Then push nut and 

tube over the fitting and tighten, 

2. 

Tubing should then be piped to a drain or container.

3.  Plug dehumidifier into the wall and turn on at switch. 

 

If the unit has not been used recently it will start operating within a few 

seconds. Screen will show ambient (current) room temperature and 

humidity. 

4. 

Set desired humidity using the plus and minus buttons. Humidity 

percentage will flash for a few seconds then set. The panel will then 

revert to current room humidity.

5.  If

 the unit has recently been used it will not start up until the Power button 

is pressed. There is then a 3 minute delay before fan starts. This is to 

protect the compressor. 

The desired humidity 

must be less than the current room humidity

otherwise the dehumidifier will register as reaching optimum and not 

operate.

6.  When the dehumidifier is operating, the orange dehumidification light will 

be showing, fan symbol spinning and the water droplet symbol pulsing. 

(Dynamic display)

7. 

If required, you can set a timer to turn the dehumidifier off after a set 

number of hours. This can be done while the unit is operating. Press the 

Function button once and then the plus or minus button to set the run 

time in hours. The display will show TIMER OFF and number of hours 

remaining until unit will automatically turn off.

8. 

There is a small holding tank in the dehumidifier – once this is full the 

pump sensors will register it as being full and discharge the water through 

the clear tubing.

9. 

To turn the unit off, press Power button. There is a time delay for 60 

seconds, during which time fan will run to allow machine to cool down.

10. Once the fan has stopped you can then turn it off at the wall.
11.  When machine is not being used, cover with supplied dust cover to 

prevent dust and overspray entering machine.

Содержание Air Patrol 90L

Страница 1: ...a suitably qualified person INTRODUCTION The CQ Air Patrol Dehumidifier is an industrial unit designed for reducing air humidity in an enclosed space Removes up to 90L of moisture per day Mobile on ea...

Страница 2: ...to climb or stand on the machine and children should not touch the dehumidifier PRODUCT INSTALLATION PRECAUATIONS 1 Environmental Requirements Indoor use only Designed for ambient temperatures between...

Страница 3: ...et number of hours Shutdown state Set timer to open and start dehumidifier Hr Huml Normal Running Press to increase the humidity set value range 10 95 Timer Setting Set Increase the timing hours Hr Hu...

Страница 4: ...ity otherwise the dehumidifier will register as reaching optimum and not operate 6 When the dehumidifier is operating the orange dehumidification light will be showing fan symbol spinning and the wate...

Страница 5: ...n is stopped it is fixed display Off State Light is off Humidity Under Normal Condition Displays current humidity Set Humidity Flashing display with setting data Fault Fault code displaying every 30 s...

Страница 6: ...t the efficiency of the dehumidifier To remove filter open latch at top and pull away Then lift filter door out of the locating pins Use warm water to clean and then dry Monthly 1 Clean condenser Use...

Страница 7: ...machine Humidity not set Set desired humidity below ambient humidity Area too big or not sealed Adjust space and seal well Abnormal Filter blocked Clean filter net Leakage Machine incline not level En...

Страница 8: ...mode Replace humidity sensor E3 Temperature Sensor Fault Replace the sensor E4 System Failure Leakage of fluorine refrigerant pipeline blockage assessment and repair by professional personnel E5 Room...