Almax Air Patrol 90L Скачать руководство пользователя страница 2

IMPORTANT SAFETY INSTRUCTION

1.  Make sure the power supply is 230V 50Hz AC. The appropriate power 

switch should be grounded.

2. 

Please ensure equipment is in good condition and no oil leakage during 

transportation. The machine 

must be transported upright

 and not tilted 

more than 45º during transportation or operation. 

The machine should 

be standing upright for at least 2 hours before use if it has been 

tilted.

3.  Do not pull the power cord out to stop dehumidifier working.

4. 

Do not put fingers or sticks into the dehumidifier.

5. 

It is dangerous to climb or stand on the machine and children should not 

touch the dehumidifier.

PRODUCT INSTALLATION & PRECAUATIONS

1. 

Environmental Requirements: 

Indoor use only 

Designed for ambient temperatures between 5 to 38°C.

 

At low temperatures the device will start automatically defrosting and 

the Automatic Defrost will be shown on display panel. During this phase 

cooling fan will continue to work but compressor will switch off.

 

Avoid use of machine in environment of strong explosives, flammable 

substances, and areas with a lot of dust.

2.  There should be no obstacles within 600mm of the machine.
3.  Check that dehumidifier is in level position.

4. 

When machine is not being used, fit the supplied dust cover to prevent 

dust and overspray entering machine.

Содержание Air Patrol 90L

Страница 1: ...a suitably qualified person INTRODUCTION The CQ Air Patrol Dehumidifier is an industrial unit designed for reducing air humidity in an enclosed space Removes up to 90L of moisture per day Mobile on ea...

Страница 2: ...to climb or stand on the machine and children should not touch the dehumidifier PRODUCT INSTALLATION PRECAUATIONS 1 Environmental Requirements Indoor use only Designed for ambient temperatures between...

Страница 3: ...et number of hours Shutdown state Set timer to open and start dehumidifier Hr Huml Normal Running Press to increase the humidity set value range 10 95 Timer Setting Set Increase the timing hours Hr Hu...

Страница 4: ...ity otherwise the dehumidifier will register as reaching optimum and not operate 6 When the dehumidifier is operating the orange dehumidification light will be showing fan symbol spinning and the wate...

Страница 5: ...n is stopped it is fixed display Off State Light is off Humidity Under Normal Condition Displays current humidity Set Humidity Flashing display with setting data Fault Fault code displaying every 30 s...

Страница 6: ...t the efficiency of the dehumidifier To remove filter open latch at top and pull away Then lift filter door out of the locating pins Use warm water to clean and then dry Monthly 1 Clean condenser Use...

Страница 7: ...machine Humidity not set Set desired humidity below ambient humidity Area too big or not sealed Adjust space and seal well Abnormal Filter blocked Clean filter net Leakage Machine incline not level En...

Страница 8: ...mode Replace humidity sensor E3 Temperature Sensor Fault Replace the sensor E4 System Failure Leakage of fluorine refrigerant pipeline blockage assessment and repair by professional personnel E5 Room...

Отзывы: