Alma FLEXICOMPT AUTONOME+ Скачать руководство пользователя страница 3

GU 7033 EN I

FORM DOC 124 A

DISPLAY/TRANSFER* THE DELIVERY DATA

VISUALIZATION OF THE LAST DELIVERY RESULTS - sub-menu 

MEtErin

In case of a dispute, 

those indications provide proof

VISUALIZATION OF ALL THE DELIVERY RESULTS - sub-menu 

MEMoriS

8669

L

GASoiL

MEtErin

ViSuALi

In case of a dispute, 

those indications provide proof

MEMoriS

Display  all  the  delivery  details 
recorded from the newest to the 
oldest

Display  a  specific  delivery 
details, by entering the date

8669

L

GASoiL

MEtErin

ViSuALi

MEtErin

LiSt

SELECt

The following details are displayed: date, measurement No. and 
time,  name  of  product,  volume  at  temperature  (Vm),  converted 
volume  (Vb)

1

,  average  flowrate,  measured  volume  of  gas  (for 

information), temperature

1

,

 

density

1

.

VISUALIZATION OF THE TOTALISERS - sub-menu 

totALiS

8669

L

GASoiL

MEtErin

ViSuALi

In case of a dispute, 

those indications provide proof

Display the totaliser 
(volume at temperature)

Vm

Vb

Display the totaliser 
(converted volume) 

(with active option)

MEtErin

*

OPTION KEY CTD+: TRANSFER MEASUREMENT DATA

MEtErin

ViSuALi

SuPErVi

+

*

OPTION KEY CTD+: TRANSFER MEASUREMENT DATA - sub-menu 

trAnSFr

0000

L

GASoiL

totALiS

MEtErin

trAnSFr

CALibrA

x4

ConFiG

nb_dAYS

Transfer  the  parameters  and  the 
measurements results to the key

Set  the  number  of  days  for  the 
transfer of the measurement results. 
All  measurements  over  the  last  N 
days will be transferred

Transfer  the  parameters  and  the  measurement 
results to the key

x2

The key must be placed on the UNI as shown below and outside potentially explosive area

0000

L

GASoiL

(

1

with active option

)

19.3

°C

Average temperature of the product

tEMPErA

Density of the product (kg/m

3

)

VM tF

830

(with active option)

tiME

15h43

Volume at temperature

Converted volume 

Vm

Vb

MASS

412

 499

L

(with active option)

 497

L

Product name

GASoiL

The key must be placed 
on the UNI as shown:

Use the key outside potentially explosive area.
Do  not  plug  the  USB  cable  during  data 
transfer.

Содержание FLEXICOMPT AUTONOME+

Страница 1: ...idate the displayed option Validate a fault Light the display during 10 seconds Reset the volume and record the last measurement data SuPErVi Unloading control Visualization Last measurement Totalisers Memorizing Supervisor Menu Calibration Season Parameters Maintenance OPTION transfer of parameters MEtErin ViSuALi NB1 If it s used with Adblue the FLEXICOMPT AUTONOME must be rinsed with water afte...

Страница 2: ...errupted at any time by closing the valve 5000L GASoiL End the unloading 4 Continue with another compartment by moving the FLEXICOMPT AUTONOME 3 Close the valve Alarm GAS 980L Alarm Validate the fault with See list of alarms page 4 APPEARANCE OF A FAULT AND DISPLAY OF AN ALARM DISPLAY THE DELIVERY INFORMATION 13 4 C 41 6m3 h Instantaneous flowrate Temperature with active option 0L diESEL 0L unLEAd...

Страница 3: ...f Display the totaliser volume at temperature Vm Vb Display the totaliser converted volume with active option MEtErin OPTION KEY CTD TRANSFER MEASUREMENT DATA MEtErin ViSuALi SuPErVi OPTION KEY CTD TRANSFER MEASUREMENT DATA sub menu trAnSFr 0000L GASoiL totALiS MEtErin trAnSFr CALibrA x4 ConFiG nb_dAYS Transfer the parameters and the measurements results to the key Set the number of days for the t...

Страница 4: ...t with card If steady alarm substitution of the UNI If steady alarm substitution of the UNI ProGrAM rAM Error on the checksum of the metrological data Saved memory fault If steady alarm substitution of the UNI If steady alarm substitution of the UNI MEMoriS Bad writting into the memory If steady alarm substitution of the UNI FuLL If a measurement result not older than 3 months is about to be erase...

Отзывы: