Страница 2: ...means electronic mechanical photocopy recording or otherwise without the prior written permission of Allworx 2008 Allworx a wholly owned subsidiary of PAETEC All rights reserved Allworx is a registered trademark of Allworx Corp All other names may be trademarks or registered trademarks of their respective owners ...
Страница 3: ...ews 4 4 Mechanical 6 4 1 Tabletop or Shelf Placement 6 4 2 Wall Mount 6 5 Electrical 8 5 1 Chassis Ground 8 5 2 Power Up Sequence 8 6 Diagnostic Port 9 7 Port Expander Configuration 10 7 1 Configuring the Port Expander Password 10 7 2 Local Connection 11 7 3 Remote Connection 12 8 Telephone Line Connection 14 9 Data Network Connection 15 10 Physical and Environmental Specifications 16 11 Regulator...
Страница 4: ...l Access Feature Key Procure the key before beginning installation at the customer site Steps for procuring the key are included in Section 2 Procuring and Installing the Internet Call Access Feature Key Installation of the Allworx Px 6 2 Expander involves the following steps 1 Procurement and Installation of Internet Call Access Feature Key on Allworx server 2 Unpacking 3 Mechanical Installation ...
Страница 5: ...lease 6 9 if it has not already been upgraded 2 Submit a request for the Internet Call Access key to allworxorders allworx com or fax to 585 421 3853 Request must include Name of requestor Name of Company Phone number Email address Px 6 2 Expander serial number Associated server serial number e g 6x 3 Once Customer Care validates the request the key will be sent to the requestor and to any additio...
Страница 6: ...ge 3 Unpacking Open the box and carefully unpack it Save all shipping and packaging materials Verify all items against the parts list shown in Table 1 If any items are missing contact your dealer or Allworx Customer Support at 866 255 9679 Quantity Item 1 Allworx Px 6 2 Port Expander 1 Power Adapter 12 VDC 1A 1 Px 6 2 Port Expander Installation Guide 1 Sheet of 4 Rubber Feet Table 1 Parts List ...
Страница 7: ... www allworx com 2008 Allworx All rights reserved Version 03 Revised May 16 2008 Page 4 1 Power LED Indicates system start up activity 2 Outside Analog Phone Line LEDs Indicates status of a particular FXO port 3 Inside Analog Extension LEDs Indicates status of a particular FXS port 4 Network LED Indicates Ethernet link status flashes for activity 3 2 4 1 ...
Страница 8: ...rved Version 03 Revised May 16 2008 Page 5 5 Diagnostic port 6 RJ 45 10BaseT 100BaseTX Auto Sensing Auto MDI MDIX Ethernet port 7 RJ 11 FXS ports for inside extensions Ports 7 8 8 RJ 11 loop start FXO for central office connection Ports 1 6 9 RJ 11 Power Fail analog phone connector 10 Ground connecting screw 11 5 5 x 2 1 mm power jack Input 12 VDC 1A center positive 7 8 5 6 9 10 11 ...
Страница 9: ...t clearance around the Port Expander s front and rear panels to allow power network and telephony connections 2 Use self drilling drywall anchors rated for at least 20 lbs with screws that are either 6 or 8 Locate two anchors that will support the upper end of the unit using the template included in Section 12 Wall Mount Template Install the anchors per the anchor manufacturer s recommendation Ins...
Страница 10: ...e Figure 3 Wall Mount Orientation 300 Main Street East Rochester NY 14445 Toll Free 1 866 ALLWORX 585 421 3850 www allworx com 2008 Allworx All rights reserved Version 03 Revised May 16 2008 Page 7 Correct Orientation Wrong Orientation ...
Страница 11: ...e rear panel See Figure 2 item 10 must be permanently connected to earth using 18 AWG wire or larger 5 2 Power Up Sequence Connect the unit s Network port to an Allworx server LAN Then connect the AC power adapter The Port Expander will automatically begin to power up As it progresses through the power up sequence the front panel Power LED will flash green If a network connection has been made and...
Страница 12: ...6 Diagnostic Port The Diagnostic connector See Figure 2 Item 5 is a serial port Should Allworx Customer Support instruct you to capture diagnostic data connect a null modem serial cable from the Diagnostic connector to the serial port on a PC Configure the PC port in accordance with the following table Baud 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None Table 2 Serial Port Configuratio...
Страница 13: ...re the Port Expander s settings may arise in the future Such situations can be made more convenient by setting the Port Expander s password during installation For security reasons Allworx Px 6 2 Port Expanders do not have a default password A site specific password must be created and entered using the Port Expander s Configuration web page Do this using the following procedure 1 If the Port Expa...
Страница 14: ...et by repeating this procedure and entering a new password 7 2 Local Connection When properly connected to the server LAN the Allworx Px 6 2 will be configured automatically This should require no manual steps although it is recommended that the password be set in accordance with the procedure above To ensure the automatic configuration is successful perform the following steps 1 If the Port Expan...
Страница 15: ...n analog phone into the Power Fail port Calls placed using this phone will be routed to the CO line connected to FXO port 1 No other ports will be functional To configure the Boot Server IP and Plug and Play Secret Key perform the following steps 1 Access the Port Expander s Configuration screen by performing Steps 1 through 7 of the procedure in Section 7 1 Configuring the Port Expander Password ...
Страница 16: ...er LED does not shine solid green within five 5 minutes Unplug and re plug the Port Expander s power adapter 11 If you have entered a new password save it for future reference If the password is lost or forgotten it can be reset by repeating the procedure in Section 7 1 Configuring the Port Expander Password and entering a new password 12 Activate the FXO and FXS ports through the Web Admin page o...
Страница 17: ... that the ports be connected as follows CO Lines Begin with port 1 and move up Telephone Handsets Begin with port 8 and move down The Power Fail Phone port may be used to connect an analog phone device that is operational in the event that the Port Expander loses power if it loses its network connection to the Allworx server or if some other hardware failure occurs When in this condition calls usi...
Страница 18: ...nnection The Network port is 10BaseT 100BaseTX auto sensing and auto MDI MDIX port Once the Port Expander is powered up and in normal mode the Network LED indicates the state of the Network link as shown below Color State Description Off No link the network is not connected On Link the network is successfully connected Green Blinking Activity data is being transmitted or received Table 5 Network P...
Страница 19: ... 2008 Allworx All rights reserved Version 03 Revised May 16 2008 Page 16 10 Physical and Environmental Specifications Dimensions W x H x D 12 1 x 1 9 x 7 6 inches 30 8 x 4 8 x 19 3 cm Weight Base Model 3 lbs Power DC 12V 1 Amp Temperature 0 40 C Humidity 15 90 RH Non condensing Table 6 Physical and Environmental Specifications ...
Страница 20: ...uired But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will pr...
Страница 21: ...ce The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5 AVIS L indice d équivalence de la sonnerie IES du présent matériel est de 0 1 L IES assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface télé...
Страница 22: ...to operate this equipment under Federal Communications Commissions rules This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioélectriques depassant les limites applicables aux appareils numérique de ...