Allworx POWERFLEX G2426 Скачать руководство пользователя страница 18

 

  POWERFLEX G2426 Managed GbE PoE Switch 

   Quick Installation and Initial Configuration Guide 

 

Page 13 

Toll Free 1-866-

ALLWORX • 585

-421-

3850

 

 

www.allworx.com 

 

Version: A  Revised: 

August 16, 2017

 

 

Chapter 4  Troubleshooting

The following table provides information for users to easily troubleshoot 
problems by taking actions based on the suggested solutions within.

Table 5: Troubleshooting Tabl

 
 
 

Symptoms 

Possible 

Causes 

Suggested Solutions 

SYSTEM LED is 

Off 

The switch is 

not receiving 

power. 

1. Check if correct power cord is connected firmly to 

the switch and to the AC outlet socket.  

2. Perform power cycling the switch by unplugging 

and plugging the power cord back into the switch. 

3. If the LED is still off, try to plug power cord into 

different AC outlet socket to make sure correct AC 

source is supplied.  

SYSTEM LED is 

RED 

An abnormal 

state has been 

detected by 

the switch. 

Check the system log within the switch from 

WEB UI to understand the abnormal state (e.g. 

exceeding operating temperature range) and 

take corresponding actions to resolve. 

Port Status 

LED is Off in 

the 

Link/Act/Speed 

Mode 

The port is not 

connected or 

the connection 

is not working. 

1. Check if the cable connector plug is firmly inserted 

and locked into the port at both the switch and the 

connected device. 

2. Make sure the connected device is up and running 

correctly. 

3. If the symptom still exists, try different cable or 

different port, in order to identify if it is related to the 

cable or specific port. 

4. Check if the port is disabled in the configuration 

settings via WEB user interface. 

Port Status 

LED is Off in 

the PoE Mode 

The port is not 

supplying 

power 

1. Check if the cable connector plug is firmly inserted 

and locked into the port at both the switch and the 

connected device. 

2. Make sure the correct Ethernet cables are used. 

3. If the symptom still exists, try different cable or 

different port, in order to identify if it is related to the 

cable or specific port. 

4. Check if the port is disabled in the configuration 

settings via WEB user interface. 

 

Содержание POWERFLEX G2426

Страница 1: ...Allworx POWERFLEX G2426 Managed GbE PoE Switch Quick Installation and Initial Configuration Guide Version A Updated August 16 2017 ...

Страница 2: ......

Страница 3: ...POWERFLEX G2426 Managed GbE PoE Switch Quick Installation and Initial Configuration Guide ...

Страница 4: ...POWERFLEX G2426 Managed GbE PoE Switch Quick Installation and Initial Configuration Guide Page ii Toll Free 1 866 ALLWORX 585 421 3850 www allworx com Version A Revised August 16 2017 ...

Страница 5: ... View of the Switch 1 Rear View of the Switch 1 LED Descriptions 2 Mode Reset Button 4 Chapter 2 Installing the Switch 6 Package Contents 6 Mounting the Switch in a 19 inch Rack 6 Mounting the Switch on Desk or Shelf 7 Connecting the AC Power Cord 8 Installing SFP Modules 8 Chapter 3 Initial Configuration of Switch 10 Initial Switch Configuration Using Web Browsers 10 Initial Switch Configuration ...

Страница 6: ...roubleshoot the POWERFLEX G2426 26 Ports L2 Managed GbE PoE Switch By reading this user guide users can perform the following tasks To check the switch status by reading the LED behavior To reset the switch or to restore the switch to factory defaults To install the switch To use a Web browser to initially configure the switch To troubleshoot the switch Front View of the Switch Figure 1 Front pane...

Страница 7: ...the mode of all RJ45 SFP ports on the switch Users can press the Mode button sequentially to switch among the two different modes Link Activity Speed mode and PoE mode Port Status LEDs indicates the current status of each RJ45 SFP port Users can check these LEDs to understand the port status in different modes after changing the mode by pressing Mode button The following table details the function...

Страница 8: ...ransmitting receiving packets and the connection speed is 1000Mbps Amber On The port is enabled and established a link to connected device and the connection speed is 10 100Mbps Amber Blinking The port is transmitting receiving packets and the connection speed is 10 100Mbps Off The port has no active network cable connected or it is not established a link to connected device Otherwise the port may...

Страница 9: ...n disabled through the switch user interface Mode Reset Button By pressing the Mode Reset Button for certain period of time users can perform the following tasks Change Port Status LED Mode to read the port status correctly in the two different modes Link Act Speed mode or PoE mode Reset the Switch to reboot and get the switch back to the previous configuration settings saved Restore the Switch to...

Страница 10: ... August 16 2017 Table 4 Mode Reset Button Descriptions Task to be Performed Time Period of Pressing Button SYS LED Behavior Port Status LED Behavior Change LED Mode 0 2 seconds ON Green LED status will be changed according the mode selected Reset the Switch 2 7 seconds Blinking Green ALL LEDs Light OFF Restore to Defaults 7 12 seconds Blinking Green ALL LEDs Stay ON ...

Страница 11: ...ve rubber feet Mounting kits Note The switch is an indoor device If it is to be used with outdoor devices such as outdoor IP cameras or outdoor WiFi APs then users are strongly suggested to install a surge protector or surge suppressor in order to protect the switch Mounting the Switch in a 19 inch Rack Step 1 Attach the mounting brackets to both sides of the chassis Insert screws and tighten then...

Страница 12: ...he rack Push it in until the oval holes in the brackets align with the mounting holes in the rack posts Step 3 Attach the brackets to the posts Insert screws and tighten them Figure 4 Attaching Brackets to the Rack Post Mounting the Switch on Desk or Shelf Step 1 Verify that the workbench is sturdy and reliably grounded Step 2 Attach the four adhesive rubber feet to the bottom of the switch Figure...

Страница 13: ...the AC power receptacle of switch Step 2 Connect the other end of the AC power cord to the AC power outlet Step 3 Check the SYS LED If it is ON the power connection is correct Figure 6 Connecting AC power cord Installing SFP Modules You can install or remove a mini GBIC SFP module from a SFP port without having to power off the switch Step 1 Insert the module into the SFP port Step 2 Press firmly ...

Страница 14: ...nitial Configuration Guide Page 9 Toll Free 1 866 ALLWORX 585 421 3850 www allworx com Version A Revised August 16 2017 Figure 7 Installing a SFP Module into a SFP Port Note The SFP ports should use UL Listed Optional Transceiver product Rated 3 3Vdc Laser Class 1 ...

Страница 15: ...the switch After changing PC s IP address for example 192 168 2 250 then you can access the Web interface of the switch using the switch s default IP address as shown below The initial switch configuration procedure is as follows Note The factory default IP address of the switch is 192 168 2 200 The factory default Subnet Mask of switch is 255 255 255 0 Initial Switch Configuration Procedure The i...

Страница 16: ...hlight Internet Protocol Version 4 TCP IPv4 then click the Properties button Note Be sure to record all your PC s current IP settings to be able to restore them later Step 6 Select the radio button Use the following IP address and enter in the IP for the PC e g any IP address not in use and in between 192 168 2 1 and 192 168 2 253 Subnet mask e g 255 255 255 0 and Default gateway that corresponds ...

Страница 17: ... see the login page of the switch as shown by Figure 9 below Figure 9 Web Interface login page If you do not see the above login page please perform the following steps Refresh the web page Check to see if there is an IP conflict issue Clean browser cookies and temporary internet files Check your PC settings again and repeat step 2 6 Enter the factory default username and password in login page Cl...

Страница 18: ... WEB UI to understand the abnormal state e g exceeding operating temperature range and take corresponding actions to resolve Port Status LED is Off in the Link Act Speed Mode The port is not connected or the connection is not working 1 Check if the cable connector plug is firmly inserted and locked into the port at both the switch and the connected device 2 Make sure the connected device is up and...

Страница 19: ......

Страница 20: ...Toll Free 1 866 ALLWORX 585 421 3850 www allworx com Version A Revised August 16 2017 ...

Отзывы: