 Integra Telecom – Allworx 6X/24X/48X 

 

 

2/25/2011 

 

 

Figure 1: interoperability network diagram 

 

Configuration Notes:  

 This section contains a detailed description of how the Allworx 6x was configured for 

interoperability testing with Integra Telecom services.   

Network Requirements: As in any VoIP deployment there must be adequate bandwidth to support VoIP 
traffic.  A proper network assessement should be performed before any VoIP deployment.  

Assumptions: 

 

All SIP Signalling uses UDP on port 5060. 

 

SIP Signalling packets use Differentiated Services Code Point (DSCP) 24. 

 

Real-Time Transport Protocol (RTP) uses DSCP 46.  

 

 

 

Licenses:  The Allworx Ip PBX must be equipped with licensing to support SIP Trunks. 

 

 

 

DID Block Setup 

 

 

1.

 

Browse to Home >> Phone System >> Outside Lines.  Click on “add new DID block”. 
 