4.1 Outline 

CS2676FX  is  the  insulation  resistance  tester,  it  is  the

 

type

 

of  small  insulation  resistance  tester, 

simple features, easy to operate and easy to learn. Voltage switches manually, voltage settings for the 
two ranges, divided into 500V and 1000V.The testing resistance value can be displayed at real time. In 
additions, the lower limit can be set according to the users

’ actual needs. It is widely used to test the 

insulation  resistance  value  of  the  electronic  components,  household  appliances,  insulation  materials, 
instrumentation, lighting appliances, electric appliances quickly and accurately

.

 

4.2 Function introduction 

4.2.1

 

Adjust the output voltage automatically

 

   The tester is controlled by the negative feedback circuit, it can automatically adjust the voltage to the 
setting value, so the output voltage will not be impacted by the load or the input power supply voltage. 
   

4.2.2 

Discharge

 

function

 

After  the  test  is  finished,  the  voltage  will  be  needed  some  time  to  discharge  fully  after  the  power  is 
turned off. The tester is with the discharge function. After the test is finished, the tester is in the "stop" 
state, which can discharge the DUT to protect the safety of the operator. 

 
4.2.3

 

Set the lower limit of the measured object

 

The added up and low key can used to set the lower limit of the resistance according to the users

’ actual 

requirements. For example: select 2M range, the test resistance range from 

200kΩ to 2MΩ, the screen   

shows the lower limit of 0.200, press the up key to increase one, long press the up key to increase ten; If 
the lower limit is set too high, you can press the low key to reduce the lower limit, the minimum lower limit 
is 

200kΩ, the lower limit value shall not be 2 MΩ higher than the upper limit, if the lower limit is set to 2 

MΩ,  when  press  the  start  key,  the  tester  will  alarm. When users  set  the  lower  limit,  the  value  will  be 
stored in the registers, the screen will display the lower limit when turn on the tester next time. 
 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CS2676FX

Страница 1: ...f 25 User Manual CS2676FX Insulation Resistance Tester The maximum output voltage of the tester can be up to 1kV Any incorrect operation maybe cause death Before operation please read notice before us...

Страница 2: ...ase send user manual together with the equipment so as not to lose If you find that missing page manual or instructions to be contaminated please contact with the dealer of Allwin company immediately...

Страница 3: ...connected to ground If there is no reliable grounding once short circuit exist between the power supply and case or between and high voltage test line and case during the testing process the case wil...

Страница 4: ...ge 8 1 7 Check and replace fuses 8 1 8 Grounding WARNING 9 2 Notice before use 10 2 1 Prohibit operation 10 2 2 Emergency treatment 11 2 3 Precautions during testing 11 3 Panel illustration 13 3 1 ill...

Страница 5: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 5 of 25 1 Unpacking and installation tester...

Страница 6: ...r accessories within the box to see if the test clips are completed Accessories 1 3 Carton and packing materials Please Save the original packing materials for use in future transportation 1 4 safety...

Страница 7: ...ent on a sloping surface or shaking of the place is easy to drop and break down 1 4 7 Do not use the tester beside the sensitive receiving equipment or testing equipment If the tester is near these eq...

Страница 8: ...th the rear panel voltage selector switch WARNING To prevent malfunction or damage to tester please use the tester in the specified voltage range 1 7 Check and replace fuses Warning To avoid electric...

Страница 9: ...ith specifications listed in the 1 7 1 4 The fixed fuse holder should be back in its original location 1 8 Grounding WARNING Improper grounding or not grounding may cause electric shock To ensure safe...

Страница 10: ...e don t turn off the power switch except in urgent cases can perform this operation 2 1 2 High voltage output and ground could not be short circuit The high voltage test leads of the tester are strict...

Страница 11: ...ose or fall off Connect the test leads with the device under test DUT be sure to connect DUT to current measurement terminal then connect DUT to high voltage terminal If test leads in current measurem...

Страница 12: ...rn off the power switch 2 3 7 After the test user must confirm the following At any time before touch high voltage leads high voltage output or the DUT make sure that 1 Power switch is off the display...

Страница 13: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 13 of 25 3 Panel Illustration 3 1 Front panel illustration 3 2 Rear panel illustration...

Страница 14: ...indicator lights if you are not sure about the resistance range please select the maximum range 2000M and then select the appropriate range according to the display resistance If the resistance is gr...

Страница 15: ...the lower limit within the measuring range 12 Current sample 13 Grounded shield end 14 High voltage output During test the output voltage is negative voltage the maximum voltage is 1kVDC 3 2 illustrat...

Страница 16: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 16 of 25 4 Function Outline 4 1 Outline 4 2 Function introduction...

Страница 17: ...load or the input power supply voltage 4 2 2 Discharge function After the test is finished the voltage will be needed some time to discharge fully after the power is turned off The tester is with the...

Страница 18: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 18 of 25 5 Technical parameters...

Страница 19: ...Ver 1 1 Page 19 of 25 5 1 Technical Parameters CS2676FX Model CS2676FX Output voltage DC Range 500V 1000V Accuracy 5 3 FS Range Test range 2M 200k 2M 5 2words 20M 2M 20M 5 2words 200M 20M 200M 5 2wor...

Страница 20: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 20 of 25 6 Parameters setting 6 1 Power on 6 2 CS2676FX Parameters setting...

Страница 21: ...the screen displays the lower limit of the range Users can press or long time press the up and down keys to set the desired lower limit Wherein the lower limit value should not be equal to the upper l...

Страница 22: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 22 of 25 7 Test Function 7 1 Connect the DUT to the tester 7 2 CS2676FX test...

Страница 23: ...T and tester After confirmation connect DUT and tester follow the Figure 8 1 If DUT is with polarity please note that the high voltage output is the negative voltage 7 2 2 Press START to begin When ST...

Страница 24: ...is warranted to be free from use for a period of 12 months from the date of shipment to the original end users in different sales spots 2 Accessories is warranted to be free for just months 8 2 2 Main...

Страница 25: ...ax 86 25 52101482 Skype trudamao MSN cy mao hotmail com Email trudamao allwin instruments net cn njmaocuiyun 163 com cswangyi 163 com Homepage www csallwin com The copyrights reserved by Allwin Instru...

Отзывы: