STEP 1: 

 

Testing the Limit Settings:

 To check the 

Limit Settings, start the Opener by pushing the standard 
wall Push Button or Super Station.  Be prepared to 
activate the button again quickly - per the Operating 
Parameters outlined on page 12 - or if you see that the 
door is going to over travel.  As illustrated below, move 
the Cams toward the Power Unit to 

DECREASE

 door 

travel and toward the Front Idler to 

INCREASE 

door 

travel.  Adjust the Up Limit Cam so that the door 
comes to rest where it normally would without an 
electric Opener. Adjust the Down Limit Cam so that 
the door closes firmly without putting undue stress on 
the Door Arm.  At full closed position, the door arm 
assembly should compress approximately one inch. 

STEP 2:  

Adjusting the Sensitivity Force — 

Sensitivity System force adjustment screws are located 
on the side rails of the Power Unit and can easily be 
adjusted with a screwdriver.  Turn the screws 

CLOCKWISE

 for more force and 

COUNTERCLOCKWISE

 for less force.  

    

STEP 3: 

Testing the Sensitivity Force — 

To test 

the Sensitivity System, start the Opener and grasp the 
bottom door handle halfway through the door's travel 
(opening or closing). 

  As an 
alternate, 
use a stiff 
cardboard 
carton 
placed in 
the door's 
downward 
path to 

indicate the force the Opener is exerting. 

If the force adjustment screws are properly set, the door 
should stop if opening, and reverse if closing without 
exerting undue pressure. 

 

 

 
 
 
 

 
STEP 4: 

 

Testing the Opener’s Reversing System 

 To test the Opener's Reversing Feature at floor level, 

place a solid object 1-1/2" thick (such as a standard 2 X 
4 board laid flat) on the ground where the center of the 
door will contact it.  Close the door. If the down force 

 

OPEN FORCE  
ADJUSTMENT 

CLOSE FORCE 

ADJUSTMENT 

104391 

OPERATION AND ADJUSTMENT INSTRUCTIONS 

108407 

WARNING 

              

W A R N I N G

 

IMPROPER ADJUSTMENT OF 

SENSITIVITY SYSTEM FORCE COULD 

CAUSE ENTRAPMENT, INJURY OR 

DEATH.  SET ADJUSTMENTS FOR JUST 

ENOUGH FORCE TO OPERATE THE 

DOOR RELIABLY, BUT NO STRONGER.  

Contact a service professional to 

correct any binding, sticking or other 

door problems.  DO NOT OVER-ADJUST 

SENSITIVITY SYSTEM TO 

COMPENSATE FOR A POORLY 

WORKING DOOR. 

THE SENSITIVITY SYSTEM REVERSING TEST 

SHOULD BE PERFORMED MONTHLY TO 

ENSURE THAT THIS IMPORTANT SYSTEM 

REMAINS IN PROPER ADJUSTMENT. 

 

       

W A R N I N G

 

16 

More Downward Travel 

Close Limit Cam 

More Upward Travel 

Open Limit Cam 

 

IF LIMITS ARE NOT 

ADJUSTED  

PROPERLY, THE 

EMERGENCY 

RELEASE 

MECHANISM MAY 

NOT WORK 

PROPERLY AND 

DOOR OPERATION 

COULD  

RESULT IN DOOR 

DAMAGE, SERIOUS 
PERSONAL INJURY 

OR DEATH!

 

Limit Cam 

Assembly 

Содержание SUPER BELT MVP-SB

Страница 1: ...ndicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard Operation and Adjustment Instructions 12 Basic Operating Parameters 12 Door Arm Connection 13 Programming The Rad...

Страница 2: ...manual operation of the door when desired as in the event of a power failure The trolley release can be set to lock out automatic reconnection if desired Page19 Automatic Reconnection Once power is re...

Страница 3: ...FINISH PHOTOSYSTEM WARNING SPRINGS PULLEYS CABLES AND MOUNTING HARDWARE USED TO BALANCE YOUR GARAGE DOOR ARE UNDER EXTREME TENSION AT ALL TIMES AND CAN CAUSE SEVERE INJURY OR DEATH IF DISTURBED DO NO...

Страница 4: ...TORMOREABOVETHEFLOOR MOUNT THEEMERGENCYRELEASE6FTABOVETHE FLOOR REINFORCELIGHTWEIGHTFIBERGLASS ALUMINUMANDSTEELDOORTOPSECTIONS TOAVOIDDAMAGEANDTOINSUREPROPER OPERATIONOFTHESAFETYREVERSE SYSTEM CONTACT...

Страница 5: ...oward the Door Front Idler see Illustration B Lock the Trolley Outer Half onto the Inner Half STEP 4 Remove and discard the tape used to keep the belt looped at the one end on the rail assembly during...

Страница 6: ...mper into its mounting hole on the Tee Rail see Illustration E for location Secure the Bumper to the bottom of the Tee Rail using one 5 16 18 x 1 hex head bolt and one 5 16 18 washered nut supplied Ti...

Страница 7: ...not rub on the Tee Rail and that you have allowed the proper clearances before proceeding STEP 4 MountPower HeadtoCeiling Since there is such variety in ceiling structures all the mounting possibiliti...

Страница 8: ...e rubber jacket of the Line Cord and wire in permanently employing proper wiring practices Discard Strain Relief It is not used with permanent wiring Step 10 Install a Rough Service lamp bulb 75 Watt...

Страница 9: ...mount the unit using appropriate screws STEP 3 Run the wire from the control to the operator supporting it at 18 intervals with suitable staples Leave a sufficient length to make the necessary connect...

Страница 10: ...ted to the jamb with a 1 flat head nail provided using the small hole above the slot Using two 5 16 X 1 1 2 lag screws provided permanently mount the L bracket to both door jambs STEP 3 Connect the Ph...

Страница 11: ...PEOPLE AND OBJECTS AWAY FROM THE DOOR AREA UNTIL THE DOOR IS COMPLETELY CLOSED NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR NEVER GO UNDER A STOPPED PARTIALLY OPEN DOOR TEST THE DOOR OPENER MONTHLY...

Страница 12: ...will then automatically turn off At this time before connecting the door arm activate the door operator through 2 cycles of operation to verify proper limit function The trolley should stop at a mini...

Страница 13: ...Align connecting hole in the door arm to middle hole in the door bracket insert 3 8 diameter bolt and tighten locking nut allowing for free pivot of the arm Note Do not overtighten locking nut as thi...

Страница 14: ...tton Continue to hold both the and buttons until the LED starts to blink approximately 5 seconds When the LED starts to blink IMMEDIATELY release both the and buttons The LED will blink two times and...

Страница 15: ...location of the transmitter and receiver antenna will affect distance If the opener doesn t activate check if the power head unit has been programmed to accept the transmitter signal The red LED on t...

Страница 16: ...a stiff cardboard carton placed in the door s downward path to indicate the force the Opener is exerting If the force adjustment screws are properly set the door should stop if opening and reverse if...

Страница 17: ...up Used to start the door upward This button will also stop and reverse a door that is closing The button has no effect on a door that is opening The function of this pushbutton is automatically disa...

Страница 18: ...om all of these devices are locked out by the operator Such devices will continue to work until the door is fully closed allowing you to set the switch when leaving on vacation for example leave the g...

Страница 19: ...ON RED LED GREEN LED Normal Operation OFF OFF Learn Mode ON OFF Memory Full ON FOR 25 SEC AUTO OFF OFF Decode RF Signal SHORT FAST BLINK OFF Shorted Push Button or Wire to Button OFF ON Photobeam Obst...

Страница 20: ...ithin the warranty period which upon receipt by Linear are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Linear s sole option at no cost and returned p...

Отзывы: