C. Connect the interconnect wire pair to the garage 

door opener terminals marked 

"1"

 & 

"4"

Although 

not required, it is suggested that the "trace" be 
connected to Terminal 4. See wiring diagrams, 
below and page 19.

 

Tighten all mounting screws and bolts.  Final 
alignment and the system test is covered on Page 18, 
“Operation and Adjustment Instructions”.

 

D: CONTROL AND AUXILIARY EQUIPMENT 

PRE-POWER ON- 

 INSTALLATION CHECKLIST 

Before continuing with the operation and 
adjustment section, make sure that

 

1.  The front and rear mounts for the opener are sound 

and secure and the rail is positioned correctly 

above the high arc of the door, and that the opener 

is positioned over the door action centerline. 

2.  For sectional door and one piece door with tracks, 

the position of the door arm (with the door closed), 

is such that it’s connecting point on the trolley is 

5” to 8” behind it’s connecting point on the door 

bracket.  The door arm should never be perfectly 

vertical when the door in in the closed position.  

    For one piece doors without tracks, the position of 

the door arm (with the door closed) is such that it’s 

connecting point on the trolley is approximately 

30” behind it’s connecting point on the door 

bracket.  The straight portion of the door arm 

should be at an angle of 15-20° with respect to the 

floor the door is closed.    

3.  The Manual Release Label and cord are secure to 

the Manual Release Lever. The handle is located 6 

FT above floor level and requires no more than a 

50 pound pull to activate.  The trolley and the 

release mechanism are properly lubricated.  

4.  All push button controls are mounted at such a 

position and of such height that they can only be 

actuated by an adult of average height.  The 

Control Button Warning label is prominently 

displayed next to the push button or Super Station.  

5.  All wiring is correct to codes or better.   There is 

ground continuity form the supply.  The ground 

prong on the power cord is intact.  

6.  All ropes have been removed from the door.  The 

door moves freely without binding when raised or 

lowered manually.  The door is correctly balanced 

and lubricated.  All door hardware is secure and 

sound.  The sensitivity has been adjusted to 

minimum force for the application. 

7.  The concrete or other surface beneath the closed 

door provided uniform contact.  

8.  The plastic envelope for this manual is attached to 

the wall near the push button or wall station and 

this manual is placed there for owner use and 

reference.   

9.  On door with extension type counterbalance 

springs, restraint cables have been placed through 

the springs.  

10.  There is Ground Fault Interruption (GFI) 

protection of the power line to the opener or in 

the receptacle.  

11.  On doors with adjustable bottom edges, edges 

have been locked after adjustment. 

108971 

 

14 

Содержание Challenger 9000M Series

Страница 1: ...ATEMENTS CAREFULLY AND FOLLOW THE INSTRUCTIONS CLOSELY The Warning and Caution boxes throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING CAUTION Indicates an ELECTRICAL hazard of DAMAGE to the door door operator or equipment Gives instructions to avoid the hazard Indicates an ELECTRICAL hazard of INJURY OR DEATH Giv...

Страница 2: ... or automatic operation of the door is again desired initiating operation in the normal manner Push Button Radio Control etc will effect automatic reconnection of the Manual Release Mechanism Page 9 Sensing System A built in sensing system detects obstructions during door operation If in the downward close travel mode the Opener will sense an obstruction and reverse the direction of the door In th...

Страница 3: ...Y MANUAL RELEASE TAG DOOR BRACKET BELL WIRE SPOOL WALL BRACKET DOOR ARM and ROD SENSOR U BRACKET SAFE FINISH SENSOR L BRACKET RED RELEASE KNOB PHOTOSYSTEM SENSORS 110046 PUSHBUTTON WARNING LABEL 110045 WALL PUSHBUTTON A ASSEMBLY INSTRUCTIONS STEP 2 Protect the Power Unit cover from scratching during assembly by placing it on cardboard Loosen the two 5 16 lock washer nuts on top of the power head d...

Страница 4: ... secure the Rail Chain assembly to the Power Head Unit making sure they are tight Assembly is now complete and you are ready to begin installation of the opener ASSEMBLY INSTRUCTIONS WARNING SPRINGS PULLEYS CABLES AND MOUNTING HARDWARE USED TO BALANCE YOUR GARAGE DOOR ARE UNDER EXTREME TENSION AT ALL TIMES AND CAN CAUSE SEVERE INJURY OR DEATH IF DISTURBED DO NOT ATTEMPT ADJUSTMENT IMPORTANT IDENTI...

Страница 5: ...S WEAR SAFETY GOGGLES OR OTHER PROTECTIVE EYEWEAR IF POSSIBLE INSTALL THE DOOR OPENER 7zFT OR MORE ABOVE THE FLOOR MOUNT THE EMERGENCY RELEASE 6 FT ABOVE THE FLOOR REINFORCE LIGHTWEIGHT FIBERGLASS ALUMINUM AND STEEL DOOR TOP SECTIONS TO AVOID DAMAGE AND TO INSURE PROPER OPERATION OF THE SAFETY REVERSE SYSTEM CONTACT YOUR DOOR MANUFACTURER FOR A REINFORCEMENT KIT DO NOT CONNECT THE OPENER TO A POWE...

Страница 6: ...loor This is the high arc rise of the door Unclamp and close the door Using the table below draw a horizontal line at the appropriate height above the door to intersect with the vertical centerline Mount the Front Mounting Bracket securely with lag screws as shown in the figure below If necessary reinforce the header with steel angle iron or wood to ensure a secure mount 104369 C INSTALLING THE OP...

Страница 7: ... cross brace the hangers to eliminate the possibility of sway during operation of the opener 110050 2 For finished ceilings or if structural beams are out of position for mounting use a third mounting angle not included making sure it is securely mounted to beams Cut and bend Hangers to fit Opener Power Head Structural Beams STEP 7 Door Bracket Installation NOTE If the door is of light constructio...

Страница 8: ...cket Visually align the door arm connecting hole with the connecting pin of the strut by rotating the tube section in the appropriate direction Release the trolley leave door arm attached with the manual release cord and pull trolley toward the power head unit Now rotate the door arm tube section two turns counterclockwise increasing the exposed length of the door rod to provide a cushion when the...

Страница 9: ...tion Ground Wire 110053 1 110055 1 Closed Limit Stop Location Open Limit Stop Location Fully Open Fully Closed Trolley Door Arm Connection Door Arm Door Arm Bracket Open Door Closed Door Door Arm IMPROPER WIRING COULD CAUSE ELECTROCUTION OR DAMAGE TO CIRCUITRY FOLLOW LOCAL BUILDING AND ELECTRICAL CODES WARNING C INSTALLING THE OPERATOR Slide door arm and trolley toward door connect the tube assemb...

Страница 10: ... screws STEP 3 Run the wire from the standard wall pushbutton to the operator supporting it at 18 intervals with suitable staples Leave a sufficient length to make the necessary connections to the opener terminal strip WARNING SOME LOCAL BUILDING CODES DO NOT ALLOW SURFACE WIRING BE SAFE AND CHECK WITH YOUR LOCAL BUILDING INSPECTOR FIRST STEP 4 Ensure power is OFF to the opener or disconnect the p...

Страница 11: ...Continue to hold both the and buttons until the LED starts to blink approximately 5 seconds When the LED starts to blink IMMEDIATELY release both the and buttons The LED will blink two times and then remain on to confirm programming mode STEP2 WhiletheLEDis on pressandreleasethe button you wish tocode The LED willblink onceand then remain on STEP3 Usingthe operationbuttonson the frontof thetransmi...

Страница 12: ...ble However environmental conditions and the location of the transmitter and receiver antenna will affect distance If the opener doesn t activate check if the power head unit has been programmed to accept the transmitter signal The red LED on the rear panel of the power head unit will blink two times rapidly if it has accepted a valid transmitter signal If the LED light does not blink reprogram th...

Страница 13: ...ws Refer to wiring diagrams on page 14 19 for the Safe Finish Photosystem connection illustration A Remove the transmitter and receiver from their U mounting brackets Run a wire pair not supplied around the garage door jamb between the transmitter and receiver L mounting brackets NOTE Leave about 12 of extra wire at each end Use a minimum 22 gauge solid trace wire for interconnect B Run a wire pai...

Страница 14: ...respect to the floor the door is closed 3 The Manual Release Label and cord are secure to the Manual Release Lever The handle is located 6 FT above floor level and requires no more than a 50 pound pull to activate The trolley and the release mechanism are properly lubricated 4 All push button controls are mounted at such a position and of such height that they can only be actuated by an adult of a...

Страница 15: ...hen reaches the down limit the lamp will blink off for a 1 2 second then turn back on again remaining on for 4 minutes 30 seconds and will then automatically turn off MOVING UPWARD then reaches the open limit the lamp will remain on for 4 minutes 30 seconds and will then automatically turn off NEVER LET CHILDREN OPERATE OR PLAY WITH DOOR CONTROLS KEEP THE REMOTE CONTROL AWAY FROM CHILDREN ALWAYS K...

Страница 16: ...additional check Operate manual release on the trolley and allow the door to seek its natural fully open position then move the open limit stops to align trolley to this position If the door does not open fully at its natural open position it indicates a door spring or hardware problem that should be referred to a door system professional Adjustment 2 Opening and Closing Force Hex nuts for adjusti...

Страница 17: ... below and stops in the fully closed position proceed to Adjustment 6 If the door reverses when it comes into contact with the floor move the close limit stop located on the left side inside looking out see figure Adjustment 1 towards the power head unit It is advised that you move the close limit stop one link at a time and run opener through another close cycle until the door stops when it comes...

Страница 18: ...btained E Tighten all mounting screws and bolts loop and secure any extra wire Important Test Photoelectric Obstruction Test Test Procedure Place an object 6 x 12 on the floor as illustrated progressively on foot from the left side of the door center of the door and one foot from the right side of the door The object must prevent an open door from closing in any other mode other than constant pres...

Страница 19: ...ge 12 for illustration Contact the factory if your problem persists or is not listed DIAGNOSTIC CONDITION RED LED GREEN LED Normal Operation OFF OFF Learn Mode ON OFF Memory Full ON FOR 25 SEC AUTO OFF OFF Decode RF Signal SHORT FAST BLINK OFF Shorted Push Button or Wire to Button OFF ON Photobeam Obstruction OFF FAST BLINK Contact Reverse FAST BLINK OFF Stuck Relay SLOW BLINK OFF Stuck Open Limit...

Страница 20: ...ed at Allstar s sole option at no cost and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Allstar s sole option This limited warranty does not cover non defect damage damage caused by unreasonable use damage caused by improper installation or care vandalism or lightning fire or excessive heat flood or other acts of God including but not limited ...

Отзывы: