background image

AMS Quick Install Guide 

 

28 

 

 

 

8. Power and Cooling Problems 

Installation 

If the power indicator does not turn on when the power cord is plugged in, you may have a problem 
with the power outlet, power cord, or internal power supply. However, if the unit powers off after 
running for a while, check for loose power connections, power losses or surges at the power outlet. If 
you still cannot isolate the problem, the internal power supply may be defective. Verify that all 
system components have been properly installed. If one or more components appear to be 
malfunctioning (such as the power cord or network cabling), test them in an alternate environment 
where you are sure that all the other components are functioning properly. 

In-band Access 

You can access the management agent in the switch from anywhere within the attached network 
using Telnet, a web browser. However, you must first configure the switch with a valid IP address, 
subnet mask, and default gateway. If you have trouble establishing a link to the management agent, 
check to see if you have a valid network connection. Then verify that you entered the correct IP 
address. Also, be sure the port through which you are connecting to the switch has not been 
disabled. If it has not been disabled, then check the network cabling that runs between your remote 
location and the switch. 

 

NOTE:

 

The  management  agent  accepts  up  to  four  simultaneous  Telnet 

sessions. If the maximum number of sessions already exists, an additional 

Telnet connection will not be able to log into the system. 

 

Содержание APS-10T2SFP

Страница 1: ...APS Series Gigabit Managed PoE Switches Quick Install Guide APS 10T2SFP APS 26T6SFP APS 48T4SFP APS 24T4S4SP APS 48T4S4SP Version 1 0 1 Oct 2012...

Страница 2: ...PS Series switches 12 3 Network Planning 13 Installing the Switch 13 Selecting a site 13 Ethernet Cabling 14 Equipment Checklist 14 Package Contents 14 Mounting 15 Rack Mounting 15 Desktop Mounting 16...

Страница 3: ...AMS Quick Install Guide 2 8 Power and Cooling Problems 28 Installation 28 In band Access 28 9 Specifications 29...

Страница 4: ...col IP and Simple Network Management Protocol SNMP Warranty The APS series comes with a standard 3 year warranty For full Alloy warranty terms and conditions please follow the link below http www allo...

Страница 5: ...erienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 thi...

Страница 6: ...of the unit must be carried out by qualified personnel only This guide is intended for use by network administrators who are responsible for setting up and installing network equipment consequently i...

Страница 7: ...exits or high temperature occurs Avoid placing the device in direct sunshine Do not put this device close to a place which is damp or wet Do not spill any fluid on this device Please follow the instru...

Страница 8: ...of Product is strictly prohibited Damage caused by self demolition will result in voiding the switches warranty Do not place product in outdoor locations Before installation please make sure input po...

Страница 9: ...individual models supporting from 8 to 48 PoE ports All models in the range feature advanced Layer 2 management functions ensuring the high performance required by modern networks supporting data voic...

Страница 10: ...warded This prevents errors from being propagated throughout the network Network Management Options The switch can also be managed over the network with a web browser or Telnet application The switch...

Страница 11: ...M 1G SFP slots and 4x 1G 10G SFP slots the 4x 100M 1G slots are again paired with ports 21 24 The APS 48T4SFP has 4x 100M 1G SFP slots the 4x 100M 1G slots are paired with ports 45 48 The APS 48T4S4SF...

Страница 12: ...TX 1310 RX 1550 40Km MGBICWDMS5 40 1G N A TX 1550 RX 1310 40Km MGBICWDMS3 80 1G N A TX 1310 RX 1550 80Km MGBICWDMS5 80 1G N A TX 1550 RX 1310 80Km 100SFP M02 100M 62 5 125 1310 2Km 100SFP S20 100M 9 1...

Страница 13: ...ondition Status TP Link ACT Green Lit Green when TP link is active Blinks when traffic is present TP Speed Green Lit Green when TP link is 1000Mbps Blinks when TP link is 100Mbps Off when TP link is 1...

Страница 14: ...ll the devices you want to link and near a power outlet Be able to maintain its temperature within 0 to 40 C 32 to 104 F and its humidity within 10 to 90 non condensing Be accessible for installing ca...

Страница 15: ...tection from radio frequency interference emissions Electrical surge suppression Separation of electrical wires and data based network wiring Safe connections with no damaged cables connectors or shie...

Страница 16: ...he following factors Temperature Since the temperature within a rack assembly may be higher than the ambient room temperature check that the rack environment temperature is within the specified operat...

Страница 17: ...If installing multiple switches please follow steps 1 and 2 for installation of the other switches Desktop Mounting 1 Attach the four adhesive rubber feet to the bottom of the switch 2 Set the device...

Страница 18: ...cable is NOT connected when you install or remove a SFP module CAUTION Use only supported genuine Alloy SFP s with your switch Non Alloy SFP s might have compatible issues and their use may result in...

Страница 19: ...the power cable is correctly plugged in WARNING For International use you may need to change the AC line cord You must use a line cord set that has been approved for the socket type in your country Co...

Страница 20: ...it data 3 RXD receive data 2 RXD receive data 5 SGND Signal ground 5 SGND Signal ground NOTE No other pins are used The Serial Ports configuration requirements are as follows Default Baud rate 115 200...

Страница 21: ...To access the web management of an APS Series switch enter the default IP Address in web browser and hit enter E g http 192 168 1 1 Once you have entered the IP Address into the web browser you will...

Страница 22: ...STP cable with RJ 45 connectors at both ends Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections Cabling Guidelines The RJ 45 ports on the switch su...

Страница 23: ...e wiring closet See the section Network Wiring Connections Otherwise attach the other end to an available port on the switch 3 As each connection is made the Link LED on the switch corresponding to ea...

Страница 24: ...uipment follows 1 Attach one end of a patch cable to an available port on the switch and the other end to the patch panel 2 If not already in place attach one end of a cable segment to the back of the...

Страница 25: ...ion at a temperature that is not less than the recommended maximum operational temperature of the product You must also use an approved Laser SFP transceiver 1 Remove and keep the LC port s rubber plu...

Страница 26: ...the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it is connect...

Страница 27: ...tion at full duplex the device will not connect correctly to the switch The result will be high error rates and very inefficient communications between the switch and the device Make sure all devices...

Страница 28: ...ymptom Action Power LED is off Check connections between the switch the power cord and the wall outlet Contact your dealer for assistance Link LED is off Verify that the switch and attached device are...

Страница 29: ...that all the other components are functioning properly In band Access You can access the management agent in the switch from anywhere within the attached network using Telnet a web browser However yo...

Страница 30: ...ts 1 24 UTP Ports 1 48 UTP Ports 1 24 UTP Ports 1 48 Max AF AT Power Per Port watts 15 4W 802 3af 30W 802 3at Total Power Budget watts 130W 250W 360W 250W 380W General Jumbo Frames 9Kb on Gigabit Inte...

Страница 31: ...ltiple host mode and single multiple sessions Supports IGMP RADIUS based 802 1x Dynamic VLAN assignment Layer 2 isolation PVE Private VLAN Edge aka protected ports for L2 isolation between clients in...

Страница 32: ...mple Network Time Protocol SNTP Trivial File Transfer Protocol TFTP SNMP RADIUS Syslog Management Web GUI interface HTTP HTTPS Dual Image Dual image provides independent primary and secondary OS files...

Страница 33: ...Detection Protocol with LLDP MED extensions Environmental Specifications Dimensions WxHxD mm 280 x 44 x 166 442 x 44 x 300 442 x 44 x 385 Case Desktop 1RU rackmount mounting kit included all metal cas...

Отзывы: