background image

 

SG-9500 Hardware Guide 

 

 

 

6

 

Deploying the SG-9500 

6.1

 

Connecting Network Traffic 

The SG-9500 operates with one or two external Bypass Units. The Bypass Unit is a 
mission-critical subsystem designed to ensure network connectivity at all times. 
The Bypass mechanism provides ‘connectivity insurance’ in the event of a 
subsystems failure. Bypass Units are connected to the SG-9500 by a series of leads 
and cables. 
Use the following procedure when connecting to the Network via the Bypass Unit.  

1.

 

Before installation make sure there is traffic flow in the location where 
you are about to install the In-line platform. 

2.

 

Connect the bypass to the Network, connecting to the Router and Switch 
via the Network ports for each Link. 
 
The following settings should be used: 

INTERFACE 

SERVICE GATEWAY 

SWITCH/ROUTER 

1G Copper 

Auto 

Auto 

1G Fiber 

Auto 

1000/Full 

10G Fiber 

Auto 

10000/Full 

40G Fiber 

Auto 

Auto 

100G Fiber 

Auto 

Auto 

 

3.

 

Connect the In-line platform to the bypass with ethernet cables using the 
System ports for each Link. Connect the Bypass management cable to the 
Primary port on the Bypass and the USB port on the SG-9500. Keep the In-
line platform turned off while connecting the cables.  

Содержание SG-9500 Series

Страница 1: ...SG 9500 Hardware Guide...

Страница 2: ...document by checking the top row of the table below Document updates are released in electronic form from time to time and the most up to date version of this document will always be found on Allot s...

Страница 3: ...rts 2 3 SG 9500 Configuration B 8 x 1 10G and 4 x 100G Ports 2 5 Power Supply 2 8 3 Bypass 3 1 3 1 External Bypass Unit 3 1 HD 4 Fiber Bypass Unit 3 2 HD 8 Fiber or Copper Bypass Unit 3 3 HD 16 Fiber...

Страница 4: ...The iLO System 6 4 Configuring the SG 9500 6 5 6 4 Active Redundancy 6 14 Physical Connections 6 14 Configuration 6 16 7 Maintenance 7 18 7 1 Component Replacement 7 18 7 2 Power Modules 7 18 7 3 Syst...

Страница 5: ...ing you to roll out Security as a Service as well as other revenue generating services rapidly and cost effectively while you lower your total cost of ownership and accelerate ROI Powerful and cost ef...

Страница 6: ...e so there must be adequate space behind the unit for safe access at all times 1 2 Packing List Verify that the following items are included with the SG 9500 Pair of AC power IEC 320 C13 C14 cables in...

Страница 7: ...h Bypass USB to DB 9 Connectors USB Bypass Cable Allot P N C245055 Included with Bypass USB to DB 9 Connectors USB Bypass Cable Allot P N C245055 Included with Bypass USB to DB 9 Connectors Between By...

Страница 8: ...ftware to 1G Full 1G Fiber interfaces must be set as Full Duplex 1G Copper interfaces may only use the 8 Port Bypass Unit if available limiting the number of ports which may be used on the SG 9500 Con...

Страница 9: ...ality in an efficient small footprint appliance With high density connectivity and throughput the platform allows enterprises cloud data centers and ISP networks to satisfy the ever growing demand for...

Страница 10: ...green 1 Hz cycle per sec iLO is rebooting Flashing amber System degraded Flashing red 1 Hz cycle per sec System critical 3 NIC status LED Solid green Linkto network Flashing green 1 Hz cycle per sec...

Страница 11: ...G Ethernet network interfaces on each of the six PCIe cards P1 P6 which can support 1G 10G SFP fiber or 1G RJ45 Copper interfaces Figure 2 5 NETWORK STEERING Links Each PCIe card has ports L1 L4 which...

Страница 12: ...ch connection are located together to the left of the interfaces NOTE 1G Copper interfaces may only use the 8 Port Bypass Unit is available limiting the number of ports which may be used on the SG 950...

Страница 13: ...Network or Steering Interfaces P5 2 x 100G Network Interfaces P6 NOT IN USE NOTE It is possible for the 100G interfaces of Configuration B to be installed with PSM 4 Transceivers MTP MTP SM Only This...

Страница 14: ...eled Px Ly where x stands for the PCIe slot number and y stands for the port number within that PCIe slot For example the second port on the third PCIe card S3 will be identified as P3 L2 See the tabl...

Страница 15: ...R port The port is implemented as D Type connection for connection of an external monitor M1 M4 may be used for system monitoring and maintenance M2 acts as a redundant port for M1 There are total 4 m...

Страница 16: ...drives one power supply It is possible for the unit to operate normally with only one of the two power supplies active NOTE The AC power supply automatically adapts to voltages between 100 V and 240 V...

Страница 17: ...Connectors and LEDs 2 9 SG 9500 Hardware Guide Figure 2 10 SG 9500 DC PEM with Grounding Screw Grounding Screw...

Страница 18: ...upports up to 4 links 8 ports and an HD 4 can support up to 2 x 100G MM links 4 ports In terms of Management each Bypass unit is connected to the SG 9500 via a single USB cable NOTE If you have mix of...

Страница 19: ...The HD 4 Bypass Unit includes MTP connectors for up to 2 x 100G MM links on the SG 9500 In addition the HD 4 Bypass Unit includes two D type 9 pin connectors DB 9 for connection to the SG 9500 via sp...

Страница 20: ...the operation of the blade Mode LED is STEADY GREEN when the Bypass Unit is operating normally and OFF when the Link is in Bypass mode HD 4 Bypass Unit Front Panel Connectors Link 1 2 connect to the...

Страница 21: ...mode as protective action is taken There is no way to have a single link go into bypass independently When moving to Bypass mode all links are switched into Bypass NOTE 1G Copper interfaces may only...

Страница 22: ...al connectors into the correct ports on the Bypass Unit In addition please note that in Fiber Bypasses on each Duplex LC connector on the Bypass unit s front panel the Tx connector is the left LC conn...

Страница 23: ...0 via special DB 9 USB cables available from Allot The HD 16 Fiber Bypass Unit is a passive optical device with no need for external power connection It is powered by the SG 9500 as long as it is Acti...

Страница 24: ...e in each Duplex LC connector on the Bypass unit s front panel the Tx connector is the left LC connector and the Rx is the right LC connector System Ports 1 16 connect to the SG 9500 Be sure to insert...

Страница 25: ...ns to connect to the SG 9500 Figure 3 7 Fan out Fiber Optic cable Single Mode A single HD 24 Fiber Bypass unit supports up to 24 ports 12 links For more links additional units are required In addition...

Страница 26: ...orts are split into twelve blocks of four each representing a link Be sure to insert the Internal and External connectors into the correct ports on the Bypass Unit Internal is on the left of each link...

Страница 27: ...to the SG 9500 by a Single USB Unit Cable 1 1 connected to the Primary port on the Bypass Unit and one of the two USB ports on the rear of the SG 9500 The cable is provided with the Bypass unit WARNI...

Страница 28: ...l injury fire or damage to the equipment do not overload the AC supply branch circuit that provides power to the rack Consult the electrical authority having jurisdiction over wiring and installation...

Страница 29: ...ondevices used in the installation such as branch wiring and receptacles are listed or certified grounding type devices Because of the high ground leakage currentsassociated with multiple servers conn...

Страница 30: ...TALLATION SITE FOR EACH SUPPLY CIRCUIT AVERTISSEMENT IL CONVIENT DE PR VOIR UNE PROTECTION CONTRE LES SURINTENSIT S DU SYST ME SUR LE SITE DE L INSTALLATION POUR CHAQUE CIRCUIT D ALIMENTATION ATTENTIO...

Страница 31: ...After the equipment arrives at the installation site carefully inspect each carton for signs of shipping damage If the package is damaged document the damage with photographs and contact the transport...

Страница 32: ...allow for servicing and adequate airflow observe the following space and airflow requirements when deciding where to install a rack Leave a minimum clearance of 63 5 cm 25 in in front of the rack Leav...

Страница 33: ...risk of personal injury or equipment damage when unloading a rack At least two people are needed to safely unload the rack from the pallet An empty 42U rack can weigh as much as 115 kg 253 lb can stan...

Страница 34: ...telecommunications connectors into RJ 45 connectors AVERTISSEMENT Pour limiter les risques d lectrocution d incendie ou de d t rioration du mat riel vitez de brancher des connecteurs de t l phone ou...

Страница 35: ...la fiche la prise secteur et au point de sortie du cordon sur le serveur DC Power Source WARNING To reduce the risk of electric shock or energy hazards This equipment must be installed by trained ser...

Страница 36: ...uit conductor between the DC source and the point of connection of the earthing electrode conductor To connect a DC power cable to a DC power source 1 Cut the DC power cord ends no shorterthan 150 cm...

Страница 37: ...fore installation make sure there is traffic flow in the location where you are about to install the In line platform 2 Connect the bypass to the Network connecting to the Router and Switch via the Ne...

Страница 38: ...is not connected to a Bypass boot will fail Figure 6 1 Connecting to Network Traffic 4 Make sure all cables are secure 5 Power up the In line platform and verify the traffic flow See page 2 1 for det...

Страница 39: ...Connected to Bypass or Steering Ext3 Cloned Connected to second SG 9500 P4 L1 10G Int7 Connected to Bypass or Steering Int4 P4 L2 10G Ext7 Connected to Bypass or Steering Ext4 P4 L3 10G Int8 Connected...

Страница 40: ...mended to connect the two power line feeds to separate power sources to have full power redundancy 1 Press the Power On Standby button The Power LED will flash green during the boot up process and the...

Страница 41: ...h up to four server administrators Remotely mount high performance Virtual Media devices to the server Securely and remotely control the power state of the managed server Implement true Agentless Mana...

Страница 42: ...ng the IP for the iLO 1 Connect a keyboard mouse and display to the SG 9500 to set the iLo s IP address via the BIOS UEFI 2 Power up the SG 9500 When the initial screen appears press F9 to open System...

Страница 43: ...screen select Network Options Figure 6 5 System Configuration Screen NOTE It is possible to change the default user name and password for the iLO by selected User Management on the System Configurati...

Страница 44: ...ed to the device via the iLo web interface which provides a console connection Logging in to iLO for the first time The iLO firmware is configured with a default user name password and IP Use these va...

Страница 45: ...stem Configuration screen see above selecting Edit Remove User Action and entering the desired values when prompted 1 Enter the IP address for the ILO into a web browser Internet Explorer or Edge reco...

Страница 46: ...or the Java Integrated Remote Console for all other browsers and click LAUNCH If either NET or Java needs to be updated you will be informed and directed to the appropriate website NOTE It is also pos...

Страница 47: ...the go config ips command to configure the IP address gateway IP DNS and NTP servers for the SG 9500 Command go config ips Usage go config ips OPTION VALUE Options h Hostname set host name of NE d Do...

Страница 48: ...copper 1G ports M3 M4 2 SFP that can accommodate any type of SFP interface 1G 10G Pair selection is done by configuring one of the pair ports to act as the management port The other port in the pair i...

Страница 49: ...t NOTE Allot STRONGLY recommends that the default passwords are changed to ensure a minimum level of security To change the sysadmin password 1 Log into the SG 9500 via the iLO Remote Console 2 Enter...

Страница 50: ...of flow s state and other information required for correct shaping and application classification In the Active Redundancy configuration the two Service Gateways should share the same policy configur...

Страница 51: ...P5 L4 L20 Cloned Ext5 to Second SG 9500 P6 L1 L21 Int6 P6 L2 L22 Ext6 P6 L3 L23 Cloned Int6 to Second SG 9500 P6 L4 L24 Cloned Ext6 to Second SG 9500 SG 9500 Configuration B 8 1 10G and 4 100G Ports...

Страница 52: ...s as indicated in the tables above to fail paired port 5 Set all cloned port indicated in the tables above to No Action in the Action on Failure field 6 Open the Networking tab and set the Redundancy...

Страница 53: ...is no need to change the port usage settings after running the previous command for enabling active redundancy the port usage for the cloned ports will be set automatically To view redundancy mode go...

Страница 54: ...ude but are not limited to the following AC DC Power Supplies 120GB SATA SSDs RAM DIMMs PCI Network Cards System Cooling Fans System RTC Battery For information concerning how to replace any element i...

Страница 55: ...injury Do not attempt to recharge the battery Do not expose the battery to temperatures higher than 60 C 140 F Do not disassemble crush puncture short external contacts or dispose of in fire or water...

Страница 56: ...s OR HD 16 16 fiber optic ports 8 links OR Single HD 24 unit 24 fiber optic ports 12 links HD 4 Bypass Unit External 1U 19 rack mount 2 44kg 5 38lb HD 8 Bypass Unit External 1U 19 rack mount 2 44kg 5...

Страница 57: ...F Operating relative humidity 8 to 90 non condensing Non operating relative humidity 5 to 95 non condensing Operating altitude 2000 m 6 561 ft Non operating altitude 9144 m 30 000 ft 8 3 Safety Certi...

Страница 58: ...er Safety Statutory Warning All personnel involved in Equipment installation operation and maintenance must be aware that laser radiation is invisible Therefore although protective devices generally p...

Страница 59: ...ni V lt altistumista ja l tuijota n ihin avoimiin aukkoihin Attention Un rayonnement laser invisible peut tre mis partir de l ouverture des ports optiques lorsque aucun c ble fibres optiques n est con...

Отзывы: