background image

 

 

Do not attempt any repairs. 

 

Do not remove the chassis cover without specific authorization from your Allnic dealer. 

 

See the notes on “Location, Location, Location”. 

 

 

CLEANING

 

 

A.

 

Chassis and glass 

 

Use only a soft, lint-free cloth dampened slightly with water only (NO cleaning fluids!) to clean 

the faceplate, meter glass and chassis. 

 

B.

 

Connectors 

 

You may use any good quality contact cleaner recommended for such applications to clean the 

contacts from time to time as you deem appropriate. 

 

 

INITIAL SET-UP

 

 

A.  LOCATION, LOCATION, LOCATION 

 

Like all audio products using tubes, the Allnic Audio L-10000 OTL/OCL needs to be placed on a 

solid stand in a location that provides for good air circulation around the preamplifier. 

 

 

DO NOT cover the top of the preamplifier. 

 

DO NOT place the unit on carpet or foam. 

 

DO NOT subject the unit to knocks and shocks as you move it around. This advice is meant 

particularly for those who may want to place the L-10000 OTL/OCL on a set of after-market 

isolation feet or similar devices. Dropping one side of the L-10000 OTL/OCL, or the whole 

unit, is not a good thing. 

 

DO NOT place the unit near a strong light or heat source. 

 

DO NOT place anything heavy on the unit. 

 

DO NOT allow rubber or vinyl materials to rest on the unit’s chassis for long periods of time. 

This could discolour the metal. 

 

 

DO place the unit on a shelf or stand that is stable and not subject to vibration or sudden 

shock. 

 

DO consider using a high quality power cord and interconnects, both inputs and outputs. The 

L-10000 OTL/OCL is a highly sensitive piece of electronic equipment designed for neutrality 

and will output what you put into it. 

Allnic’s Zero Loss Technology power cables and MU 

metal shielded interconnects will work synergistically with the L-10000 OTL/OCL. 

 

DO try to place the L-10000 OTL/OCL away from major sources of RFI and EMI; though well 

shielded, the L-10000 OTL/OCL will function best away from large power transformers and 

other sources of such interference. 

Содержание L-10000

Страница 1: ...ALLNIC AUDIO L 10000 OTL OCL LINE STAGE PREAMPLIFIER OWNER S MANUAL...

Страница 2: ...e sound of this high quality device will be rewarded by its excellent operation for years to come Please read this entire manual before you connect the L 10000 OTL OCL Line Stage Preamplifier to the o...

Страница 3: ...tion Location Power Connection Inputs Outputs Remote Control 7 8 8 8 8 INITIAL POWER ON 9 OPERATION 10 CURRENT METERS 10 TUBES 11 SPECIFICATIONS 12 WARRANTY 13 FIGURES 14 Please read about SAFETY befo...

Страница 4: ...te amplifiers Removal of these two coupling devices from the signal path achieves the best results possible No colouration of the musical signal Extremely detailed expression natural harmonics and sub...

Страница 5: ...n 61 STEP CONSTANT IMPEDANCE BRIDGED TYPE ATTENUATOR A world s first of its kind for Allnic Audio The L 10000 OTL OCL does not employ a digital IC volume control or a low cost carbon film volume contr...

Страница 6: ...e an excellent match Of course only you can determine the power cord that works most synergistically with the L 10000 OTL OCL in your system 3 Be sure the L 10000 OTL OCL is labeled for the AC voltage...

Страница 7: ...icularly for those who may want to place the L 10000 OTL OCL on a set of after market isolation feet or similar devices Dropping one side of the L 10000 OTL OCL or the whole unit is not a good thing D...

Страница 8: ...The L 10000 OTL OCL is a line stage preamplifier and does NOT have a built in phono preamplifier section You will need a phono preamplifier if you want to use a turntable with the L 10000 OTL OCL You...

Страница 9: ...CAREFULLY AND SLOWLY removed ALL the cardboard cushion materials from inside the tube chimneys ensured the batteries are in the remote control if not insert the batteries by removing plate on the bot...

Страница 10: ...now ready for operation At this point you can power on your sources and finally your stereo power amplifier or mono blocks OPERATION From this point on operation is straight forward All functions are...

Страница 11: ...two parallel lines If the needle has moved to the left of the parallel lines on either meter it means that one or both of the third gain stage tubs 300B for that channel is failing If the needle on e...

Страница 12: ...z to 100kHz Voltage Gain 18dB THD 1kHz Less than 0 03 1kHz 1V RMS S N Ratio 100dB CCIR 1kHz Maximum Output 20V RMS Non clipping Output Impedance 200 Constant Power Consumption 120W at 110 120V 60 Hz 1...

Страница 13: ...st materials and manufacturing defects for one 1 year from date of purchase The warranty is transferable for the balance of the original purchaser s warranty period provided as stated below no unautho...

Страница 14: ...14 FIGURES Figure 1 L 10000 OTL OCL Left Side Panel View...

Страница 15: ...15 Figure 2 L 10000 OTL OCL Rear Panel View Figure 3 L 10000 OTL OCL Remote Control...

Страница 16: ...16 Figure 4 L 10000 OTL OCL Front Panel View...

Страница 17: ...17 Figure 5 L 10000 OTL OCL Top View...

Отзывы: