ALLNIC AUDIO L-10000 Скачать руководство пользователя страница 11

11 

 

gain stages are set up and functioning properly, the needles of the meters should be in the centre 

between the two parallel lines in the middle of the meters. 

 

These illuminated meters perform two functions: 

 

 

First, the meters are used to balance the outputs of the third gain stage tubes for the right 

and left channels, as explained above in “Initial Set-up”. 

Remember, when replacing the 

300B tubes be sure to turn the screw for each meter so the needle is on or just below the 

left-hand parallel line on the meter’s face. 

The L-10000 must be powered off to remove 

and insert tubes.

 

 

 

Second, the meters are indicators of failure or damage to the function of the unit. Any failure 

of the tubes or circuits in one or the other of the L-10000 OTL/OCL’s channels is indicated by 

the needle on the meter for the respective channel moving out from between those two 

parallel lines. 

 

 

If the needle has moved to the left of the parallel lines on either meter, it means that 

one or both of the third gain stage tubs (300B) for that channel is failing. 

 

 

If the needle on either meter moves to the right of the parallel lines, it means that one 

or both of the first and second gain stage tubes (6AN8 or 12AU7) for that channel is 

failing. 

 

In the case of any failure indicated by the meter, please contact Allnic Audio or its authorized 

representative for assistance. 

 

 

TUBES 

 

The L-10000 OTL/OCL uses the following tubes (see Figure 5): 

 

 

Two (2) x 6AN8 

 

Two (2) x 12AU7 

 

Four (4) x 300B 

 

All consequences of changing or attempting to change tubes are borne by the user unless by 

express agreement between the owner and Allnic Audio or its authorized representative. Allnic 

Audio and its authorized representatives are not liable in any way whatsoever for any injury or 

loss incurred by the user or for damage to the L-10000 OTL/OCL, any of its parts, or tubes or 

replacement tubes resulting from the user changing or attempting to change tubes. 

 

 

 

Содержание L-10000

Страница 1: ...ALLNIC AUDIO L 10000 OTL OCL LINE STAGE PREAMPLIFIER OWNER S MANUAL...

Страница 2: ...e sound of this high quality device will be rewarded by its excellent operation for years to come Please read this entire manual before you connect the L 10000 OTL OCL Line Stage Preamplifier to the o...

Страница 3: ...tion Location Power Connection Inputs Outputs Remote Control 7 8 8 8 8 INITIAL POWER ON 9 OPERATION 10 CURRENT METERS 10 TUBES 11 SPECIFICATIONS 12 WARRANTY 13 FIGURES 14 Please read about SAFETY befo...

Страница 4: ...te amplifiers Removal of these two coupling devices from the signal path achieves the best results possible No colouration of the musical signal Extremely detailed expression natural harmonics and sub...

Страница 5: ...n 61 STEP CONSTANT IMPEDANCE BRIDGED TYPE ATTENUATOR A world s first of its kind for Allnic Audio The L 10000 OTL OCL does not employ a digital IC volume control or a low cost carbon film volume contr...

Страница 6: ...e an excellent match Of course only you can determine the power cord that works most synergistically with the L 10000 OTL OCL in your system 3 Be sure the L 10000 OTL OCL is labeled for the AC voltage...

Страница 7: ...icularly for those who may want to place the L 10000 OTL OCL on a set of after market isolation feet or similar devices Dropping one side of the L 10000 OTL OCL or the whole unit is not a good thing D...

Страница 8: ...The L 10000 OTL OCL is a line stage preamplifier and does NOT have a built in phono preamplifier section You will need a phono preamplifier if you want to use a turntable with the L 10000 OTL OCL You...

Страница 9: ...CAREFULLY AND SLOWLY removed ALL the cardboard cushion materials from inside the tube chimneys ensured the batteries are in the remote control if not insert the batteries by removing plate on the bot...

Страница 10: ...now ready for operation At this point you can power on your sources and finally your stereo power amplifier or mono blocks OPERATION From this point on operation is straight forward All functions are...

Страница 11: ...two parallel lines If the needle has moved to the left of the parallel lines on either meter it means that one or both of the third gain stage tubs 300B for that channel is failing If the needle on e...

Страница 12: ...z to 100kHz Voltage Gain 18dB THD 1kHz Less than 0 03 1kHz 1V RMS S N Ratio 100dB CCIR 1kHz Maximum Output 20V RMS Non clipping Output Impedance 200 Constant Power Consumption 120W at 110 120V 60 Hz 1...

Страница 13: ...st materials and manufacturing defects for one 1 year from date of purchase The warranty is transferable for the balance of the original purchaser s warranty period provided as stated below no unautho...

Страница 14: ...14 FIGURES Figure 1 L 10000 OTL OCL Left Side Panel View...

Страница 15: ...15 Figure 2 L 10000 OTL OCL Rear Panel View Figure 3 L 10000 OTL OCL Remote Control...

Страница 16: ...16 Figure 4 L 10000 OTL OCL Front Panel View...

Страница 17: ...17 Figure 5 L 10000 OTL OCL Top View...

Отзывы: