INSTRUCTION MANUAL OPTIONS

OPTION M-BUS

The optional M-Bus option allows the UltraMaXX to be 
connected to a wired M-Bus remote reading system. The 
communication parameters primary address, secondary 
address and baud rate can be displayed via the liquid-crys-
tal display (LCD). The parameters can be set by authorised 
service personnel using the service software via the optical 
interface / M-Bus option, or set directly via the buttons on 
the UltraMaXX. 
Default factory setting: 
Primary address: 

Secondary address: 

Meter  

number baud rate: 

2400 baud

Setting the M-Bus parameters using the buttons on the 
device:
1)  Remove the user seal above button 2 
2)  Use button 1 to display the value to be adjusted must 
 

then be selected 

 

Primary address:    Display 3.17 

 

Secondary address: Display 3.18 

 

Baud rate: 

  Display 3.19

3)  Press button 2 for longer than 2  
 

seconds: The display or the right  

 

digit in the display flashes.

4)  Set the desired value by pressing button
5)  Press button 2: digit one position further to the left  
 

flashes (only for primary/secondary address).

6)  Repeat procedure 4.) and 5.) until the desired value is  
 

set. Possible settings:  

 

Primary address:    1 - 250 

 

Secondary address: 00000001-99999999 

 

Baud rate: 

  300, 2400 baud

7)  Press button 2 for longer than 2 seconds to exit the  
 

settings mode.

8)  Secure button 2 against manipulation by means of a  
 

new user seal.

OPTION WATER METER INPUTS

The UltraMaXX offers the option of connecting up to  
4 water meters with a remote indicator output at the unit. 
The meter readings of the water meters (displays 1.7 /  
1.8 / 1.9 / 1.10), including the key date values (displays  
2.X.4 / 2.X.5 / 2.X.6 / 2.X.7), can be read via the display, 
M-Bus or optical interface on the UltraMaXX. The meter 
readings, the number of water meters and the pulse value 
of the water meters can be set by authorised service 
personnel using the service software via the optical inter-
face / M-Bus option, or set directly via the buttons on the 
UltraMaXX.

Programming water meter inputs: 

1)  Remove the user seal above button 2

Pulse value water meter 

2)  Use button 1 to select the water meter pulse value  
 

display (3.20)

3)  Press button 2 for longer than 2 seconds >> display  
 flashes
4)  Use button 1 to set the desired value
5)  Press button 2 for longer than 2 seconds to exit the  
 

settings mode.

Number of water meters 

6)  Use button 1 to select the number of water meters  
 

display (3.21)

7)  Press button 2 for longer than 2 seconds >> display  
 flashes.
8)  Use button 1 to set the desired value (1- 4).
9)  Press button 2 for longer than 2 seconds to exit the  
 

settings mode.

Meter reading of water meter 

10)  Use button 1 to select the volume display (1.7).
11)  Press button 2 for longer than 2 seconds: the right  
 

digit in the display flashes.

12)  Set the desired value by pressing button 1.
13)  Press button 2: the digit one position further to the left  
 flashes
14)  Repeat procedure 12.) and 13.) until the desired value 
 

is set.

15)  Press button 2 for longer than 2 seconds to exit the  
 

settings mode.

16)  If required, repeat steps 10 to 15 for additional water  
 meters. 
 

Water meter 2 >> display 1.8 

 

Water meter 3 >> display 1.9 

 

Water meter 4 >> display 1.10

17)  Secure button 2 against manipulation by means of a  
 

new user seal.

User seal

Button 1

INSTRUCTION MANUAL OPTIONS

INSTRUCTION MANUAL OPTIONS

Temperature-type

Value 

Tariff

Unit

Condition

Temperature type:

 

Temperature difference 

 

Supply temperature 

 

Return temperature

Tariff:

Tariff 1

Tarfif 2

Unit:

°C  

Temperature

m

3

/h  Flow rate

kW  

Power

Bedingung:
 

less than

 

greater than / equal to

TIME WINDOW 

A time window can be selected as the tariff. The start time (    ) 
end time (     ) is represented as follows:

Energy above threshold value 1/2  

Time above/below threshold value in 
hours (h)
Energy value above/below threshold 
value 
Tariff (1 or 2)

Volume above threshold value 1/2 

Time above/below threshold value in 
days
Volume value above/below threshold 
value 
Tariff (1 or 2)

OPTION MAXIMUM VALUES

These optional displays show the current monthly 
maximum values for power (3.11), flow rate (3.12) and 
supply temperature (3.13) with time stamp. 18 maximum 
monthly values are stored internally for each item, which 
can be read out via M-Bus, optical interface or the LCD 
display at the key date level (2.X.8 / 2.X.9 / 2.X.10). The 
period duration for determining the maximum values 
is 60 minutes. The period duration can be varied via 
M-Bus or the optical interface with the help of the service 
software, in a range from 1 min - 1440 min (= 1 day).

OPTION TARIFF FUNCTION 
(NOT AVAILABLE FOR COMBI METERS) 

With the optional tariff function, the values for energy 
(1.12 / 1.14) and volume (1.13 / 1.14) are shown in ad-
ditional displays, under previously defined operating 
conditions. These operating conditions can be defined 
via one of the following parameters:
-  Temperature difference  -  Flow rate
-  Supply temperature 

-  Power

-  Return temperature 

-  Time window

These parameters are programmed in the factory, and 
can be changed by authorised service personnel using 
the service software via M-Bus or optical interface, if 
the displays are not marked with the § symbol. It is not 
possible to adjust the parameters using the buttons on 
the UltraMaXX.

DESCRIPTION OF THE DISPLAYS:  
THRESHOLD VAUE TARIFF 1/2

Содержание Itron UltraLite

Страница 1: ...n instructions Installation instructions flow rate sensor screw in heat meter CF UltraMaXX 4 5 Installation instructions Temperature sensor Information on identification of immersion sleeves 6 7 Insta...

Страница 2: ...ted Always install the meter according to the mounting position printed on the serial plate supply or return The flow sensor can be installed either horizontally or vertically in any mounting position...

Страница 3: ...ged when removing the unit and during installation Caution ensure tension free installation if necessary ensure that the pipes are sufficiently anchored in front of and behind the heat meter 86 128 10...

Страница 4: ...1 2 SW24 53 TH005 1 2 SW 30 52 TH040 1 2 SW24 46 TH043 3 8 SW24 57 TH044 1 2 SW24 57 TH046 M10x1 SW17 46 TH048 1 4 SW17 49 TH054 M10x1 SW17 49 TH067 1 4 SW17 59 TH068 1 4 SW17 69 TH077 M10x1 SW13 39...

Страница 5: ...ing in the installation point 4 Position the brass screw in connection correctly on the temperature sensor using the loosely inserted grooved pin 5 Place the end of the installation aid over the tempe...

Страница 6: ...ftware version 18 key date data sets Energy volume optional maximum values of power flow rate and sup ply temperature with time stamp volume of water meter 1 4 CONNECTION DIAGRAM CONNECTION DIAGRAM CO...

Страница 7: ...key date 1 6 Cold energy year end key date for combi meters 1 7 Volume water meter 1 1 8 Volume water meter 2 1 9 Volume water meter 3 1 10 Volume water meter 4 1 11 Threshold value tariff 1 1 12 Ene...

Страница 8: ...display change approx every 2 seconds standard displays optional displays depending on options ordered Activation of the display by a brief button press Change the display within one level by brief b...

Страница 9: ...Press button 2 for longer than 2 seconds to exit the settings mode Meter reading of water meter 10 Use button 1 to select the volume display 1 7 11 Press button 2 for longer than 2 seconds the right...

Страница 10: ...up to 7 days The time and the internal error messages are also saved for all loggers If the maximum number of stored values of a logger is reached the oldest value is discarded and the new value is s...

Страница 11: ...ility for errors and omissions With regard to these marketing materials no warranty is accepted either explicitly implicitly or statutory including but not limited to guarantees regarding the non infr...

Отзывы: