Allmess Itron UltraLite Скачать руководство пользователя страница 7

12

13

INSTRUCTION MANUAL

INSTRUCTION MANUAL 

EXPLANATION OF THE DISPLAYS

1. LCD level consumption data

1.1 

Cumulative energy in kWh, MWh or GJ

1.2 

Cumulative volume in m3

1.3 

Segment test (function test of all display segments)

2. LCD level key date values

The UltraMaXX stores the respective cumulative end-of-month values for energy and volume for the last 18 months. These 
values are shown in the 2nd LCD level. The display starts with the month-end value of the cumulative energy of the previous 
month in relation to the reading date, and then goes one month back into the past every 2 seconds until the 18th month 
value is reached. 
From the 18th month value, the display then jumps back to the 
1st display value (previous month).
2.1 / 2.1.1 

Month-end value energy previous month 

2.1.2 

Month-end value volume previous month 

2.2 / 2.2.1 

Month-end value energy 2 months back 

2.2.2 

Month-end value volume 2 months back 

2.3 / 2.3.1 

Month-end value energy 3 months back 

2.3.2 

Month-end value volume 3 months back 

2.4 - 2.17 

see above 

2.18 / 2.18.1  Month-end value energy 18 months back 
2.18.2 

Month-end value volume 18 months back

3. LCD level service data

3.1 

current flow in m

3

/h. 

3.2 

current power in kW 

3.3 

current supply temperature in °C. 

3.4 

current return temperature in °C. 

3.5 

current temperature difference in °C. 

3.6 

Time in error state in hours (h) 

3.7 

Operating time 

3.8 

Time with excessive flow in hours (h) 

3.9 

Error code:

 

 

1  -  Error supply sensor >> Check supply sensor including cable for integrity and correct installation

 

 

2  -  Error return sensor >> Check return sensor including cable for integrity and correct installation 

 

 

3  -  Temperature sensor reversed >> Check correct installation of temperature sensor

 

 

4  -  Error A/D converter >> Replace device with new device

 

 

5  -  Return flow in flow rate sensor >> Check correct installation (flow direction) of the flow rate sensor and/   

 

 

    or the EATs

 

 

6  -  Air in flow rate sensor >> Flush air from flow rate sensor with high flow or no communication with flow  

 

 

    rate sensor. Cable damaged >> Replace device with new device 

 

 

7  -  Current flow rate above maximum flow rate >> Reduce flow rate in flow rate sensor

 

 

8  -  Error electronics >> Replace device with new device  

In the event of multiple errors, these are displayed simultaneously (e.g. 12---6--) 
3.10   

Firmware version

Month
Value

Year

Unit

Month
Value

Year

Unit

Years

Days (d)

INSTRUCTION MANUAL

OPTIONAL DISPLAYS  
(DEPENDING ON OPTIONS ORDERED)

1.4 

Cumulative cold energy for combi meters,  

 

heat energy is displayed in 1.1 

1.5 

Energy year-end key date 

1.6 

Cold energy year-end key date for combi meters 

1.7 

Volume water meter 1 

1.8 

Volume water meter 2 

1.9 

Volume water meter 3 

1.10 

Volume water meter 4 

1.11 

Threshold value tariff 1 

1.12 

Energy above threshold value 1 

1.13 

Volume above threshold value 1 

1.14 

Threshold value tariff 2 

1.15 

Energy above threshold value 2 

1.16 

Volume above threshold  

value 2 x = 1-18 months with key date function  
2.x.3 

Month-end value cold energy in combi  

 

meters x months back 

2.x.4 

Volume water meter 1 x months back 

2.x.5 

Volume water meter 2 x months back 

2.x.6 

Volume water meter 3 x months back 

2.x.7 

Volume water meter 4 x months back 

2.x.8 

Maximum value power x months back 

2.x.8.1 Value 
2.x.8.2 Time 
2.x.8.3 Date 
2.x.9 

Maximum value flow rate x months back 

2.x.9.1 Value 
2.x.9.2 Time 
2.x.9.3 Date 
2.x.10 

Maximum value temperature x months back 

2.x.10.1 Value 
2.x.10.2 Time 
2.x.10.3 Date 
3.11 

Maximum value power 

3.11.1 

alue + time 

3.11.2 

Value + day 

3.11.3 

Value + year 

3.12 

Maximalwert des Durchflusses 

3.12.1 

Wert + Uhrzeit 

3.12.2 

Wert + Tag 

3.12.3 

Wert + Jahr 

3.13 

Maximum value of temperature 

3.13.1 

Value + time 

3.13.2 

Value + day 

3.13.3 

Value + year 

3.14 

Threshold value temperature difference for  

 

combi meter 

3.15 

Threshold value supply temperature for  

 

combi meter 

3.16 

Date and time 

3.17 

M-Bus primary address 

3.18 

M-Bus secondary address 

3.19 

Baud rate communication interfaces 

3.20 

Water meter pulse value 

3.21 

Water meter number

DISPLAY

A  Service figure: 

-  Energy measurement  
 stopped

B Warning 

US signal level: 

-  Low signal level

C Temperatures: 

- permanent:  
  Tv, Tr or T 
- flashing. error

D  Metrology indicator: 

-  Display value  
  for business traffic 
  allowed (country 
 dependent)

E  Flow rate indicator: 

-  permanent: flow rate 
-  flashing: no flow

F  Date and time 

stamp: 

-  e.g. key date values,  
  max. values

G  Display level: 

-  Currently selecte 
  display level

H Units: 

-  Physical unit

I  Pulse value: 

-  External water 
 meters

J  Maximum value: 

-  Power, flow rate, 
  supply T

K  Battery symbol: 

-  Check calibration  
 validity

L  Tariff function
M  External water 

meters: 

-  Number of water  
  meters connected

N  Main display 8  

digits: 

- Digit size:  
  6.5 x 3.3 mm

N

A B C

D E

F

G

H

I

J

K

L

M

POSSIBLE DISPLAYS IN THE EVENT OF  
MALFUNCTIONS

When the service figure is shown on the display, the energy 
calculation is interrupted. Possible errors are indicated in the 
warning messages display code (3.9).

Meter in unprogrammed state. 
Replace device with a new device.

No value for current flow rate (3.1). See 
warning message in the display 3.9.

No value for current power (3.2). See 
warning message in the display 3.9.

No value for current supply tempera-
ture, return temperature or temperature 
difference (3.3, 3.4 or 3.5). See warning 
message in the display 3.9.

Содержание Itron UltraLite

Страница 1: ...n instructions Installation instructions flow rate sensor screw in heat meter CF UltraMaXX 4 5 Installation instructions Temperature sensor Information on identification of immersion sleeves 6 7 Insta...

Страница 2: ...ted Always install the meter according to the mounting position printed on the serial plate supply or return The flow sensor can be installed either horizontally or vertically in any mounting position...

Страница 3: ...ged when removing the unit and during installation Caution ensure tension free installation if necessary ensure that the pipes are sufficiently anchored in front of and behind the heat meter 86 128 10...

Страница 4: ...1 2 SW24 53 TH005 1 2 SW 30 52 TH040 1 2 SW24 46 TH043 3 8 SW24 57 TH044 1 2 SW24 57 TH046 M10x1 SW17 46 TH048 1 4 SW17 49 TH054 M10x1 SW17 49 TH067 1 4 SW17 59 TH068 1 4 SW17 69 TH077 M10x1 SW13 39...

Страница 5: ...ing in the installation point 4 Position the brass screw in connection correctly on the temperature sensor using the loosely inserted grooved pin 5 Place the end of the installation aid over the tempe...

Страница 6: ...ftware version 18 key date data sets Energy volume optional maximum values of power flow rate and sup ply temperature with time stamp volume of water meter 1 4 CONNECTION DIAGRAM CONNECTION DIAGRAM CO...

Страница 7: ...key date 1 6 Cold energy year end key date for combi meters 1 7 Volume water meter 1 1 8 Volume water meter 2 1 9 Volume water meter 3 1 10 Volume water meter 4 1 11 Threshold value tariff 1 1 12 Ene...

Страница 8: ...display change approx every 2 seconds standard displays optional displays depending on options ordered Activation of the display by a brief button press Change the display within one level by brief b...

Страница 9: ...Press button 2 for longer than 2 seconds to exit the settings mode Meter reading of water meter 10 Use button 1 to select the volume display 1 7 11 Press button 2 for longer than 2 seconds the right...

Страница 10: ...up to 7 days The time and the internal error messages are also saved for all loggers If the maximum number of stored values of a logger is reached the oldest value is discarded and the new value is s...

Страница 11: ...ility for errors and omissions With regard to these marketing materials no warranty is accepted either explicitly implicitly or statutory including but not limited to guarantees regarding the non infr...

Отзывы: