INSTALLING THE EQUASCAN pMIU
RF
Equipment required: screwdriver, pliers.
The EquaScan pMIU
RF
can be:
- Screwed on the wall
- Fixed with tie-ups on a pipe
• First, the radio module shall be configurated. Please follow the programming steps described below.
• The distance between 2 EquaScan pMIU
RF
must be 20 cm minimum.
• The cable length for the Meter connection to the EquaScan pMIU
RF
shall be not exceed 10m.
• A fitting extension cable with 1m length can be ordered under the following order-no.: 17799
• Connect the signal wires of the EquaScan pMIU
RF
to the pulse emitter with the « scotch-lock » type connectors.
There is no need to strip the signal wires.
• Close the cover with the metallic screw.
• Place the blue user plastic seal on the screw.
To initially start the EquaScan pMIU
RF
the wires GND(black or brown) and TAMP(green) have to be connected. If an Itron
Cyble Sensor (3wires/5wires) is attached, this connection is ensured by the Cyble Sensor.
Radio specifications
Protocol
EN 13757-3/-4 wireless M-BUS
Operating mode
C2 Mode
Frequency Band
Tx: 868,95 MHz / Rx: 869,525 MHz
Electromagnetic compatibility
Interference Immunity: ETSI EN 301 489-1-V1.9.2 (2011-09)
ETSI EN 301 489-3-V1.6.1
ETSI EN 301 489-17-V2.2.1
EN 61000-3-2 (2006+A1 / 2009+A2 / 2009)
EN 61000-3-3 (2008)
Emitted Frequency :
ETSI EN 300 220-1 (V2.4.1)
ETSI EN 300 220-2 (V2.4.1)
Limitation of human exposure to
electromagnetic fields
EN 62311 (2008)
Information technology safety
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
PROGRAMMING
To ensure the correct data transmission between the pulse emitting meter and
the EquaScan pMIU
RF
, the meter parameter must be defined and programmed
into the module. To do this, the EquaScan software is used. Each EquaScan
pMIU
RF
has an inductive interface, over which the module is configured. Informa-
tion on the index and device can be read and recorded over at any time, inde-
pendently of the radio operation. The inductive interface serves to quickly and
accurately parameterize and read data via the computer using an inductive head
(Order No.8090000006). See picture for positioning the inductive head.
READING AND PROGRAMMING THE MODULE
After the EquaScan pMIU
RF
has been read via the inductive interface, the entry form for the EquaScan pulse meter RF
module parameters becomes available. The activated programming parameters can be selected and overwritten with new
values. These changes are adopted in the module when the next writing process begins. Other module values and param-
eters can be read from the various selection fields.
WARNING
The responsibility, in case of deviation between the mechanical index and the electronic index of the EquaScan pMIU
RF
,
cannot be attributed to Itron. We invite the users to check carefully the connection between the module and the EquaScan
pMIU
RF
. We strongly recommend to proceed with the configuration of the EquaScan pMIU
RF
before connecting the pulse
emitting meter. We strongly recommend the installation of non-return valve or breaks to avoid the risk of reverse flow.