ITA
ENG
FRA
ESP DEU POR
4/8
6-1622111 rev.1 18/09/2012
8. SUN – WIND radio climatic sensor
The control unit allows to utilize a sun – wind sensor radio type. The control unit integrates the reception of
the radio signal with special protocol and identifies and handles the radio sensor.
Since the meteorological sensors impose the opening or closing of the shutter, it is of fundamental
importance to select the correct sense of motor’s rotation.
8.1 SUN radio sensor
The control unit is realized in way to carry out the opening of the shutter on the occasion of the transition
night to day, while it realizes the closure of the shutter to the luminosity transition day to night. Moreover
the re – opening for light has been integrated at the end of eventual alarms (wind or disconnection).
Press and keep pressed the reset/learning
key present on the card for almost 10
seconds.
1
3
2
The control unit emits ONE
beep
Release the reset / learning key present on
the card.
The control unit emits a
series of short beep.
Select the desired typology by 10 seconds
as follows:
•
Press UP (radio) to select the
AWNING typology.
•
Press DOWN (radio) to select the
SHUTTER typology.
7. AWNING/SHUTTER selection
The control unit is supplied with awning factory configuration.
To select the typology of installation proceed as follows
The control unit emits 3 short beep
to indicate the AWNING typology.
The control unit emits 2 short beep
to indicate the SHUTTER
typology.
NOTE: the maximum time for the selection is of 10 seconds, more than the phases ends and the typology
remains unchanged.
8.2 Deactivation light sensor
It is possible to deactivate the light sensor functionality in any moment and consequently do not make
automatically go up and down the automation as function of the light variation. To deactivate the light
sensor proceed as follows:
Press and keep pressed a transmitter’s
key (almost for 8 seconds)
.
1
2
The control unit emits 2 beep to indicate
the deactivation of the sensor.
The control unit emits 3 beep to indicate
the reactivation of the sensor.
Release the key
Содержание MICRO CAP SENS
Страница 1: ...MICRO CAP SENS CENTRALINA DI COMANDO PER UN MOTORE 230 Vac...
Страница 7: ......
Страница 9: ...MICRO CAP SENS CONTROL UNIT FOR ONE 230 Vac MOTOR...
Страница 15: ......
Страница 17: ...MICRO CAP SENS CENTRALE DE COMMANDE POUR UN MOTEUR 230 Vac...
Страница 23: ......
Страница 25: ...MICRO CAP SENS CENTRAL DE MANDO PARA UN MOTOR 230 Vac...
Страница 31: ......
Страница 33: ...MICRO CAP SENS Schaltsteuerung f r eine 230 Vac Motor...
Страница 39: ......