M2E
ENGLISH
6-1622720 rev1 03/04/2014
8
Diagram of terminal strips and keys:
M/2000E
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
19 20 21 22 23 24
M/2000E
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
19 20 21 22 23 24
Port 1 : enabling relay contact
FUN DEC INC VAL
YELLOW BLUE RED GREEN
FUN DEC INC VAL
YELLOW BLUE RED GREEN
Port 2 : enabling relay contact
Port 1 : enabling relay contact
Port 2 : enabling relay contact
TERMINAL STRIP
1
Port 2: relay contact N.C.
13
Port 1: enabling contact relay
2
Port 2: relay common
14
Port 1: relay activation key
3
Port 2: relay contact N.O.
15
GROUND
4
Port 2: enabling contact relay
16
Port 1: data input (DATA1)
5
Port 2: relay activation key
17
Port 1: data input (DATA0)
6
GROUND
18
Port 1: output for reader power supply (9Vdc)
7
Port 2: data input (DATA1)
19
Antenna
8
Port 2: data input (DATA0)
20
Antenna braid
9
Port 2: output for reader power supply (9Vdc)
21
Serial line (RS485) : B
10
Port 1: relay contact N.C.
22
Serial line (RS485) : A
11
Port 1: relay common
23
Power supply, + 12-24Vac/dc
12
Port 1: relay contact N.O.
24
Power supply, - 12-24Vac/dc
Note: Make sure that terminals 4 and 13 are connected to terminals 6 and 15, respectively (see figure) in order to enable the corresponding relay
outputs 1 & 2. This contact is particularly useful for enabling, for instance, the relay outputs of the M2E via external devices such as buried magnetic
coils (opening command given by the M2E only in case of a vehicle being present on the coil so as to avoid undesired opening caused by accidental
radio transmission) or via timed relays (M2E enabled within a given time interval), as well as for closing the normally open contact of a switch, and so
on.
Note: The input to force the activation of the single door (respectively the clamp 5 and 14) it is active if referred to GND.
DECLARATION OF CONFORMITY
Hereby, declares that M2E is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The complete declaration of conformity is available in Prastel.
M2E
F1
: Relay 1 setup
F2
: Relay 2 setup
F3
: Radio channel
→
Relay 1
F4
: Radio channel
→
Relay 2
F5
: Password
F6
: Block program
F7
: Block erase
F8
: Erase all
F9
: Data copy
F10
: Memory mode
F11
: Serial port mode
F12
M2E
F1
: Relay 1 setup
F2
: Relay 2 setup
F3
: Radio channel
→
Relay 1
F4
: Radio channel
→
Relay 2
F5
: Password
F6
: Block program
F7
: Block erase
F8
: Erase all
F9
: Data copy
F10
: Memory mode
F11
: Serial port mode
F12
Содержание M2E