7.4 Pre-blinking function.
Pre-blinking function enabled. The gate motion is always signalized by a pre-blink, advising the user that
the gate is ready to start. Pre-blinking time is fixed for 2 seconds approximately.
7.5 Condominium function.
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
This light flashes slowly (approximately once every two seconds) to warn the opening gate and quickly (approximately once a second) to warn clo-
sing gate.
Pre-blinking function disabled
Condominium function enabled.
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
All inputs given remotely or by using the pulse button only open the gate. The door closes again automatically and as result, the automatic re-
closing function has to be actived, because the close command is ignored from the system (the close key is disabled).
Condominium function disabled.
7.6 Photocell test.
Every time the motor is switched on, the control unit automatically controls if the photocells are functioning properly. This operation increase the se-
curity system if a photocell is damaged (for instance output relay stuck) or in case of undesired photocell input short circuit.
This test is executed after the control unit has received an order of “moving“, but before power is applied to the motor.
Installation notes:
Power supply to ALLMATIC photocells, or compatible types, must be connected to different terminals, depending on wheter it is necessary to activa-
te or de-activate testing on the photocells. The correct wiring diagram for a couple of photocells is the following:
Wiring diagram with photocells
TEST NOT ACTIVE (DIP6 ON)
Wiring diagram with photocells
TEST ACTIVE (DIP6 OFF)
24
RX
24
TX
24
RX
24
TX
13 14 15
13 14 15
DIP6 OFF: Photocells test enabled. The command is not
performed if the photocells are faulty.
DIP6 ON: Photocells test disabled.
Note: If the photocells test is active, the motor is delayed
by approximately one second from the moment in which
the order is received.
7.7 Methods for limit switch interventions.
The end of the opening and closing operations is entrusted to the set operational time and setting of dips 7
and 8.
NOTE:
if limit switches are not installed, place dip 7-OFF and dip 8-ON:
ON
OFF
1 2 3 4 5 6 7 8 9 10
7.7.1 Model ARGO2: If limit switches are installed, these operate in the following ways:
Start of slowdown only in opening: the start of slo-
wdown phase in opening is set off by the intervention
of both limit switches (one for each wing), while it is
only timed in closure (see diagram below)
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
Arrest with limit switch: the end of the opening (limit
switch 1) or closing (limit switch 2) operations deter-
mined by the corresponding limit.
ON
OFF
1 2 3 4 5 6 7 8 9 10
Arrest without opening limit switch: only the closing
selection is defined by time intervention of the corre-
sponding limit switch.
Type of limit switch
Function
Limit switch 1
No operation
Limit switch 2
End closing operation
Type of limit switch
Function
Limit switch 1
End opening operation
Limit switch 2
End closing operation
Type of limit switch
Function
Limit switches 1and
2 positioned for opening
Start of slowdown in
opening
Closing limit switch
No operation