6-1622192      rev. 14    21/09/2012 

3/9 

6. Regulation. 

By cutting the bridge indicated in the figure, it is possible to 

increase the working time. 

0° 

WORK TIME 

7” 

55” 

0° 

WORK TIME 

55” 

2’10” 

0° 

2nd: WING D. 

7” 

55” 

0° 

55” 

2’10” 

2nd: WING D. 

The trimmer settings, made during the gate movement, 
haven’t any immediate effect. They become effective only 
after the stop of the gate or after the switching off and  the 
following switching on the central unit. 

IMP.The increase of the working times does not in-
fluence on the automatic reclosure time and on the 
pedestrian time 

Automatic re-closing  

time regulation 

A. RECL. TIME 

 0° 

270° 

Working time regula-

tion 

0° 

WORK TIME 

 0° 

270° 

ARGO 2: Delay and working time 
regulation of 2nd wing 
ARGO 1: Opening pedestrian time 
regulation. 

2nd: WING D. 

0° 

270° 

In  the  last  part  of  its  movement  (opening  and/or  closure),  the  gate  winds  slow  down  proportionally  to  the  work  time  setted 
(“WORKING TIME“ for the symmetrical gate, “WORKING TIME” and  “2nd:WING D.” for the asymmetrical one).  
It is possible to disactivate the slow-downs or adjusting the slow-down phase as described in sections 11.C e 11.D. 
In symmetrical gates it may be necessary to insert a delay time in the second gate wind i(closing phase). 
Select dip-switch 9 OFF position and regulate this time delay by the “2nd: WING D” trimmer . 
 
In the case of Argo 2 motors, for asymmetrical gates there is the possibility to define working time for second wing differently from 
the first one wing. Select dip-switch 9 ON position and regulate working time of second wing by the “2nd: WING D“ trimmer. 

It is possible to regulate the gate motion by ap-
propriately using of special trimmers 
(“WORKING TIME”, “A.RECL.TIME”, 
“2nd:WING D.”)  and selecting the setting up of 
the DIP-SWITCH, according to the type instal-
lation and needs of the wireman. As you may 
note from the figures below, the trimmers have 
a range from 0° to 270° where inside, the desi-
red regulation can be obtained with good preci-
sion. 

6.1 Gate movement regulation. 

5.2 Using the hidden key of an enabled transmitter already learnt.  

Function active only with B.RO rolling code models 
1.  Using a staple, press the hidden button of a transmitter already learned. The learning function is 

pointed out when the blinking light switches on.  

2.  Press the key of the transmitter you prefer to memorize; the flasher will blink (twice with a new co-

de, once if already learned). The central unit returns to his normal functioning state and the new 
transmitter can activate the motor.  

Push the 
hidden taste 
“e” 

led 

a b 

c d 

a b 

led 

1.  Disconnect power supply.  
2.  Supply power by keeping pressed the self-learning key for further 4-5 second. All codes are delated 

and the flashing light turns on for a total time of approximately 10 sec. When the blinking light swi-
tches off, all transmitters are deleted and the memory module is prepared to receive the fixed code 
or the rolling-code, depending on how Jumper is setting. 

5.3 Using an enabled open memory transmitter.  

Function enabled only with B.RO models with rolling code and removable memory only 
1.  Press any “memory open” key on the transmitter previously enabled by using the B.RO PRO or 

B.RO BASIC ming tool. The receivers enters in self-learning modality (the light starts to blink).  

2.  Press the button of the transmitter you wish to enable; the light blinks twice with a new code, once if 

already learned. The control unit comes back to his standard mode and the new transmitter is now 
ready for operation. 

5.4 Transmitters deletion and production values setting. 

a b 

Flashing light 

a b 

Flashing light 

Acc 
Premere auto 
apprendimento 

led 

Shifting

 

time

 

Shifting

 

time

 

Содержание ARGO 1 Series

Страница 1: ...work in the more consonant measure with the installation and making anyway attention to the fact that an excessive increasing of the time could mask the slowing down in opening and in closure see para...

Страница 2: ...with the gate closed Pressing and releasing the learning taste turn on the flashing light so transmit with the transmitter to learn considerino that The tastes must be learned one by one With the firs...

Страница 3: ...ing up of the DIP SWITCH according to the type instal lation and needs of the wireman As you may note from the figures below the trimmers have a range from 0 to 270 where inside the desi red regulatio...

Страница 4: ...ore starting the opening one This function makes it possible to open the electric lock in any case even in bad wea ther conditions such as in the event of ice Water hammer is active for opening stage...

Страница 5: ...cells The correct wiring diagram for a couple of photocells is the following Wiring diagram with photocells TEST NOT ACTIVE DIP6 ON Wiring diagram with photocells TEST ACTIVE DIP6 OFF 24 RX 24 TX 24 R...

Страница 6: ...Re closing after a stop in photocells beam disabled 7 7 2 Model ARGO1 If limit switches are installed these operate in the following ways ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF...

Страница 7: ...the following 1 Close the gate by means of a step by step order 2 Once the gate has stopped moving and the flashing light is off press the UP key the blinking light signals reception of key by a brie...

Страница 8: ...control that other selections working time torque are suitable for the gate you are automa ting The reset memory operation readecuate this value to the feature production The central unit comes with a...

Страница 9: ...available Fixed code Rolling code Fixed code Rolling code Fixed code Fixed code Fixed code Fixed code Rolling code Turned antenna impedance 50 Number of codes available 4096 FIXED CODE reception 18 b...