Allmatic ARGO 1 Series Скачать руководство пользователя страница 1

ITA 

 ENG 

 FRA 

 ESP 

 DEU 

 POR 

6-1622192      rev. 14    21/09/2012 

1/9 

ARGO 1 -  ARGO 2 SERIES 

SWITCHBOARDS, PROGRAMMABLE FOR 1 OR 2 MOTORS 

WITH INDEPENDENT SLOWDOWN CONTROL 

1. Introduction. 

IMPORTANT:  DO NOT INSTALL THE SWITCHBOARD BEFORE READING THE INSTRUCTIONS!!!! 

The Argo control unit is an apparatus fit to manage operation and control of 1 or 2 wing gates with 230V AC motors and power of up to 600W each. 

The time functioning  of the control unit, being of electronic type, is extremely precise. It is however possible that,  due to the type of the motor 

 normally utilised, the corner of the travelling time of the wing is strongly influenced by the frictions that the wing self meets during the 
course. 
Consequently , also if the time is correctly set, the corner of the  wings’ opening can not be always the same wished. 
Therefore it is advisable that the installer  considers it, increasing, if necessary, the times of work in the more consonant  measure with 
the installation and making anyway attention to the fact that an excessive increasing of the time could mask the slowing down in opening 
and in closure (see paragraph 6). 

For the correct functioning it is also necessary the installation of the mechanical stops  in opening and in closure (see pag. 6). 

2. Configuration

3. Electrical connections.

 

Electrolock output 

12 Vac 12W Max 

Indicator of open gate 

24 Vac 2W max. 

Connector 

transformer 

Dip-switch 

Fuse 

Connector 

radio 

module 

Trimmer of 

regulation 

Learning  

button 

Power supply 
230 Vac 50 Hz. 

Molex radio 

module 

Table of contents: 

FOTO CH = Photocell closing 
FOTO AP = Photocell opening 
AP = open 
CH = close 
Com = Common 
PP = step by step button 
Ant = Antenna 
PED = Pedestrian button 
F.C. 1 = limit switch 1 
F.C. 2 = limit switch 2 

Any  control  or  safety  device  de-
signed  for  acting  as  a  Normally 
Closed  (N.C.)  contact,  must  be 
provided  with  a  jumper,  if  not 
used. 

  3    4     5    6    7    8     9   10  11 12  

Motor 2 

Motor 1 

Photocells 

power supply 
 (see par.7.6) 

Flashing light 230 Vac 60W max 

N.B.: Use flashing light B.RO LIGHT FIX. 

 (Without autoflashing circuit

) 

Содержание ARGO 1 Series

Страница 1: ...work in the more consonant measure with the installation and making anyway attention to the fact that an excessive increasing of the time could mask the slowing down in opening and in closure see para...

Страница 2: ...with the gate closed Pressing and releasing the learning taste turn on the flashing light so transmit with the transmitter to learn considerino that The tastes must be learned one by one With the firs...

Страница 3: ...ing up of the DIP SWITCH according to the type instal lation and needs of the wireman As you may note from the figures below the trimmers have a range from 0 to 270 where inside the desi red regulatio...

Страница 4: ...ore starting the opening one This function makes it possible to open the electric lock in any case even in bad wea ther conditions such as in the event of ice Water hammer is active for opening stage...

Страница 5: ...cells The correct wiring diagram for a couple of photocells is the following Wiring diagram with photocells TEST NOT ACTIVE DIP6 ON Wiring diagram with photocells TEST ACTIVE DIP6 OFF 24 RX 24 TX 24 R...

Страница 6: ...Re closing after a stop in photocells beam disabled 7 7 2 Model ARGO1 If limit switches are installed these operate in the following ways ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF...

Страница 7: ...the following 1 Close the gate by means of a step by step order 2 Once the gate has stopped moving and the flashing light is off press the UP key the blinking light signals reception of key by a brie...

Страница 8: ...control that other selections working time torque are suitable for the gate you are automa ting The reset memory operation readecuate this value to the feature production The central unit comes with a...

Страница 9: ...available Fixed code Rolling code Fixed code Rolling code Fixed code Fixed code Fixed code Fixed code Rolling code Turned antenna impedance 50 Number of codes available 4096 FIXED CODE reception 18 b...