![Allied 95G2DFV Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/allied/95g2dfv/95g2dfv_installation-instructions-manual_2901750048.webp)
507052-05
Page 48 of 54
Issue 1922
Blower Performance
Model
Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
95G2DF045BV12
High Fire
35 - 65
+
735
830
1015
1210
Normal
680
750
930
1070
-
625
695
835
1000
Low Fire
20 - 50
+
705
780
975
1110
Normal
655
730
890
1055
-
595
670
790
960
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
2nd Stage
+
895
1050
1210
1360
Normal
805
965
1105
1250
-
735
865
1000
1130
1st Stage
+
640
755
850
975
Normal
580
695
780
880
-
545
645
720
795
Model
Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
95G2DF070BV16
High Fire
35 - 65
+
1110
1305
1430
1700
Normal
995
1175
1315
1520
-
880
1055
1170
1365
Low Fire
25 - 55
+
860
1020
1140
1340
Normal
795
910
1030
1230
-
680
825
910
1085
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
2nd Stage
+
1110
1340
1575
1800
Normal
995
1230
1420
1650
-
880
1085
1290
1460
1st Stage
+
740
915
1055
1255
Normal
660
820
940
1120
-
575
735
850
995