95G2DFV Maximum Allowable Intake or Exhaust Vent Length in Feet
Concentric Termination at Elevation 0 - 4,500 ft
Number
of 90°
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
Capacity
045
070
090
110
045
070
090
110
045
070
090
110
045
070
090
110
1
15
n/a
n/a
n/a
58
43
27
7
90
90
74
39
106
106
99
99
2
10
53
38
22
n/a
85
85
69
34
101
101
94
94
3
n/a
48
33
17
80
80
64
29
96
96
89
89
4
43
28
12
75
75
59
24
91
91
84
84
5
38
23
7
70
70
54
19
86
86
79
79
6
33
18
n/a
65
65
49
14
81
81
74
74
7
28
13
60
60
44
9
76
76
69
69
8
23
n/a
55
55
39
n/a
71
71
64
64
9
18
50
50
34
66
66
59
59
10
13
45
45
29
61
61
54
54
Concentric Termination at Elevation 4,501 - 10,000 ft
Number
of 90°
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
Capacity
045
070
090
110
045
070
090
110
045
070
090
110
045
070
090
110
1
15
n/a
n/a
n/a
58
43
27
n/a
90
90
74
39
106
106
99
99
2
10
53
38
22
85
85
69
34
101
101
94
94
3
n/a
48
33
17
80
80
64
29
96
96
89
89
4
43
28
12
75
75
59
24
91
91
84
84
5
38
23
7
70
70
54
19
86
86
79
79
6
33
18
n/a
65
65
49
14
81
81
74
74
7
28
13
60
60
44
9
76
76
69
69
8
23
8
55
55
39
n/a
71
71
64
64
9
18
n/a
50
50
34
66
66
59
59
10
13
45
45
29
61
61
54
54
*Size intake and exhaust pipe length separately. Values in table are for intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
Table 7B.