508115-01
Issue 2043
Page 2 of 57
Technical Specifications - A95DF1E
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nominal
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Downflow
A95DF1E045B12S
44,000
42,000
95.0% 1-1/2 — 3
1/2
120 - 60 - 1
15
6.8
40
131
A95DF1E070B16S
66,000
64,000
95.0% 2-1/2 — 4
1/2
120 - 60 - 1
15
8.4
40
146
A95DF1E090C16S
88,000
85,000
95.0% 2-1/2— 4
1/2
120 - 60 - 1
15
8.4
40
162
A95DF1E110C20S 110,000 106,000 95.0%
3 — 5
1/2
120 - 60 - 1
15
10.9
40
174
Note: For vent length and clearances to combustibles, please reference installation instructions.
MODEL NUMBER GUIDE
Numeric Code
S = Stainless Steel Heat Exchanger
08 = 2 ton add on cooling
12 = 3 Ton add on cooling
16 = 4 Ton add on cooling
20 = 5 Ton add on cooling
B = 17.5 Width
C = 21.0 Width
A = Flagship
95 = 95% Efficiency
UH = Upflow/Horizontal
DF = Downflow
1 = 1 Stage
E = High Efficiency Motor
Heating Input x 1000