508187-01
Issue 2116
Page 2 of 51
Technical Specifications - A80UH2E
PHYSICAL AND ELECTRICAL DATA
Model
High Fire
Low Fire
AFUE
(ICUS)
Nom.
Cooling
Capacity
(tons)
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Overcurrent
Protection
Nominal
F.L.A.
Trans.
(V.A.)
Motor
Output
(hp)
Approx.
Weight
(lbs.)
Input
(Btuh)
Output
(Btuh)
Input
(Btuh)
Output
(Btuh)
UPFLOW
/
HORIZONT
AL
A80UH2E045A12
44,000 35,000 29,000 23,000
80.0
3
1/2 120-60-1
15
6.1
40
1/2
111
A80UH2E070A12
66,000 53,000 43,000 35,000
80.0
3
1/2 120-60-1
15
6.1
40
1/2
121
A80UH2E090B12
88,000 70,000 57,000 46,000
80.0
3
1/2 120-60-1
15
6.1
40
1/2
136
A80UH2E090B16
88,000 69,000 57,000 46,000
80.0
4
1/2 120-60-1
15
8.2
40
3/4
140
A80UH2E110C16 110,000 86,000 72,000 58,000
80.0
4
1/2 120-60-1
15
8.2
40
3/4
152
A80UH2E110C20 110,000 87,000 72,000 58,000
80.0
5
1/2 120-60-1
15
10.0
40
1
156
Note: For vent length and clearances to combustibles, please reference installation instructions.
Note: Filters and provisions for mounting are not furnished and must be field provided.
MODEL NUMBER GUIDE
Major Revision
Revision Code
Nom. CFM x 00
12 = 3 Ton add on cooling
16 = 4 Ton add on cooling
20 = 5 Ton add on cooling
Cabinet Width
A = 14.5” width
B = 17.5” width
C = 21.0” width
BTUH Input
Heating Input x 1000
A
Flagship
AFUE
80 = 80% Efficency
Configuration
UH = Upflow/Horizontal
Stages
2 = Two Stage
Blower Drive
E = Constant Torque ECM
A 80 U H 2 E 110 C 20 01