Camera Link registers
126
Goldeye Camera Link Register Controls Reference V1.0.0
RegUserSetCount
Contains the number of user sets available in the camera including the factory
settings.
RegUserSetInq
Register name
RegUserSetCount
Register type
IntReg
Access mode
R
Address
0x00017100
Length (Bytes)
4
Bits used
31..0
Register name
RegUserSetInq
Register type
MaskedIntReg
Access mode
R
Address
0x00017000
Length (Bytes)
4
Bits used
31
Bit assignment
Bit
Name and description
31
Contains 1 if the camera supports user sets.