144
Alvium USB Cameras User Guide V3.6.4
Specifications
White balance default
Alvium color cameras are balanced for neutral color reproduction with an
illumination of 5000 °K (warm daylight).
Table 62
shows default values for the red
and blue channel by model.
For different illuminations, use auto white balance or adapt the color channel
values manually.
Feature description
See the Alvium Features Reference at
www.alliedvision.com/en/support/
technical-documentation/alvium-usb-documentation
.
Alvium model
Sensor model
Red channel value
Blue channel value
1800 U-040c
Sony IMX287
2.360
2.030
1800 U-050c
ON Semiconductor PYTHON 480
1.930
1.500
1800 U-052c
Sony IMX426
2.290
2.000
1800 U-120c
ON Semiconductor AR0135CS
1.760
1.650
1800 U-158c
Sony IMX273
2.355
2.100
1800 U-240c
Sony IMX392
2.355
2.100
1800 U-291c
Sony IMX421
2.290
2.000
1800 U-319c
Sony IMX265
2.355
2.100
1800 U-500c
ON Semiconductor AR0521SR
2.120
1.520
1800 U-501c NIR
ON Semiconductor AR0522
1.500
1.770
1800 U-507c
Sony IMX264
2.355
2.100
1800 U-508c
Sony IMX250
2.355
2.100
1800 U-511c
Sony IMX547
2.870
2.000
1800 U-811c
Sony IMX546
2.870
2.000
1800 U-1236c
Sony IMX304
2.355
2.100
1800 U-1240c
Sony IMX226
2.620
1.810
1800 U-1242c
Sony IMX545
2.870
2.000
1800 U-1620c
Sony IMX542
2.870
2.000
1800 U-2040c
Sony IMX541
2.870
2.000
1800 U-2050c
Sony IMX183
2.660
1.830
1800 U-2460c
Sony IMX540
2.870
2.000
Table 62: Alvium default values for color channels
Monochrome and VSWIR models
White balance default does not apply to monochrome and VSWIR models.
i