![Allied Vision Technologies Prosilica GC1290 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/allied-vision-technologies/prosilica-gc1290/prosilica-gc1290_technical-manual_2903219019.webp)
GC1290 Technical Manual
Page 15
Installing GigE Viewer for Testing
o
The latest Viewer software can be downloaded from
http://www.alliedvisiontec.com/us/support.html
.
o
Run the GigE Viewer Installer.exe. This will install the Prosilica GC Digital Camera drivers as
well as the GigE Viewer application program.
o
Plug in the Prosilica GC camera via the Gigabit Ethernet port. Plug in the power connection.
Verify that the Status LED 2 is a solid green. Run the GigE Viewer Application. It will take a few
seconds for the camera to be recognized. If the camera does not appear in the Viewer list after
approximately 10 seconds then try disconnecting and reconnecting the power. If it still does
not appear restart the viewer. If it still does not appear, see the Trouble Shooting section of
this document.
o
See Figure 8. Select the
wrench
icon to change camera settings. Change the PacketSize to a
value of 1500. Select the
eye
icon to image. The camera should now be imaging. If the
camera is not imaging, see the Trouble Shooting section of this document. Note that the
PacketSize can be set to 8228 if the network card has been optimized to support jumbo frames.
o
See the System Optimization Section to maximize the performance of your system.
Figure 8. GigE Viewer application window.