Allied Vision Technologies GX1660C Скачать руководство пользователя страница 35

GX1660 User Manual 

 

70-0057A-A

 

Allied Vision Technologies (Canada) Inc. 

 

 

33

 
Auto - The exposure time will vary continuously according to the scene illumination. The Auto 
exposure function operates according to the Auto and DSP controls  
 
AutoOnce - The exposure will be set once according to the scene illumination and then remain at that 
setting even when the scene illumination changes. The AutoOnce exposure function operates 
according to the Auto and DSP controls  
 
External - When ExposureMode is set to External the exposure time will be controlled by an external 
signal appearing on SyncIn1 or SyncIn2. In order for this feature to work, the parameter 
FrameStartTriggerMode must be set to SyncIn1 or SyncIn2. This feature is supported in version 1.36 
firmware and above. It is not available on any of the CMOS-based cameras.  

 

ExposureValue

 – In microseconds. The sensor integration time. 15000 corresponds to 15 ms integration 

time, 1000 corresponds to 1ms, etc.  

Gain 

 

Auto

  

 
This group of controls relates to the camera auto gain function.  
NOTE: The camera must be acquiring images in order for the auto gain algorithm to update. 
 

GainAutoAdjustDelay

 – Currently unimplemented.  

GainAutoAdjustTol 

- In percent. A threshold. Sets a range in variation from GainAutoTarget in which 

the auto gain algorithm will not respond. Can be used to limit gain setting changes to only larger 
variations in scene lighting. 
 

GainAutoMax

 – In dB. Sets the upper bound to the gain setting in Auto gain mode.  

 

GainAutoMin

 – In dB. Sets the lower bound to the gain setting in Auto gain mode. Normally this 

number would be set to zero.  
 

GainAutoOutliers

 - In percent. The percentage of image pixels that do not have to fit into the auto 

gain range  
 

GainAutoRate

 - In percent. Determines the rate at which the auto gain function changes the gain 

setting. 
 

GainAutoTarget

 - In percent. Controls the general lightness or darkness of the Auto gain feature. A 

percentage of the maximum GainValue.  

 

GainMode 

 

Manual - The camera gain is fixed by GainValue parameter.  
 
Auto - The gain will vary continuously according to the scene illumination. The Auto gain function 
operates according to the Auto and DSP controls. Available on cameras with version 1.36 firmware 
and above.  
 
AutoOnce - The gain will be set once according to the scene illumination and then remain at that 
setting even when the scene illumination changes. The AutoOnce gain function operates according to 
the Auto and DSP controls  

 

GainValue

 – In dB. G

dB

 = 20 log

10

(V

in

/V

out

). The gain setting applied to the sensor. Default gain is zero, 

and gives the best image quality. However, in low light situations, it may be necessary to increase the 
gain setting. 

 

Содержание GX1660C

Страница 1: ...Allied Vision Technologies Canada Inc www alliedvisiontec com tel 604 875 8855 fax 604 875 8856 2010 Allied Vision Technologies Inc All rights reserved USER MANUAL January 11 2010 GX1660 GX1660C...

Страница 2: ...upported Features 3 Mechanical 4 Connections 5 Cleaning the Sensor 11 Adjusting the C mount 12 Network Card Configuration 13 GigE Sample Viewer and Filter Driver 17 Trouble Shooting 18 Addendum 21 GX...

Страница 3: ...P SHIPPING MATERIAL Poor packaging of this product can cause damage during shipping VERIFY ALL EXTERNAL CONNECTIONS Verify all external connections in terms of voltage levels power requirements voltag...

Страница 4: ...ter 0 5 s Operating Temperature 0 to 40 Celsius with standard housing 0 to 50 Celsius with thermal housing Operating Humidity 20 to 80 non condensing Size and Weight See mechanical diagrams Hardware I...

Страница 5: ...0 seconds in 1 microsecond increments Gain 0 to 34dB Region of Interest ROI independent x and y control with 1 pixel resolution Horizontal Binning 1 to 8 pixels Vertical Binning 1 to 8 rows Pixel Form...

Страница 6: ...GX1660 User Manual 70 0057A A Allied Vision Technologies Canada Inc 4 Mechanical GX C MOUNT...

Страница 7: ...GX1660 User Manual 70 0057A A Allied Vision Technologies Canada Inc 5 Connections GX CONNECTION DIAGRAM...

Страница 8: ...SYNC IN 2 12 SYNC OUT 2 GENERAL PURPOSE IO PORT AS SEEN FROM BACK OF CAMERA The General Purpose I O port uses a Hirose HR10A 10R 12PB connector on the camera side The mating cable connector is Hirose...

Страница 9: ...a For best performance the connection for EXTERNAL POWER should be physically close to the POWER GROUND connection SYNC INPUTS 1 and 2 The input signals allow the camera to be synchronized to some ext...

Страница 10: ...ER VCC R VCC USER GND USER SYNC OUT USER TRIGGER CIRCUIT T4 CAMERA CIRCUIT T2 TLP281 4GB 1 2 16 15 T3 IF 5mA CAMERA LOGIC SIGNAL 3 3V CAMERA LOGIC SIGNAL SYNC OUT SIGNAL T1 Various USER VCC values and...

Страница 11: ...ted and reference power ground If these signals are used in the system care must be taken to prevent ground loop problems USER GROUND This connection provides the user ground reference and return path...

Страница 12: ...tage requirements of 6V up to 12V or lenses which operate with bipolar voltages from 6V up to 12V This voltage level can be controlled through software The default voltage will be set to 6V The curren...

Страница 13: ...he IR filter carefully using a small flat head screw driver Clean both sides of the IR filter using the same techniques as explained below for the sensor window DO NOT TOUCH ANY OPTICS WITH FINGERS OI...

Страница 14: ...the locking ring is loose unthread the ring a few turns from the camera face A wrench suitable for this procedure can be provided by AVT Canada Inc P N 11 0048A Image to Infinity Use a c mount compat...

Страница 15: ...Ethernet ports into a single data channel 1 Install a dual port network card in the host computer To achieve full camera performance you should use a Gigabit Ethernet card that supports Jumbo frames o...

Страница 16: ...Windows firewall The camera will not work if the firewall is active If you installed the Prosilica GigE filter driver this step is not required 8 Perform Steps 1 8 for the other Ethernet adapter port...

Страница 17: ...your system Click Next to continue 12 Select the two Ethernet ports to which the GX camera will be connected These ports will form our LAG or TEAM Click Next to continue 13 Choose Static Link Aggregat...

Страница 18: ...Canada Inc 16 15 Once completed the properties of the TEAM LAG that has just been created will appear A new Network Connections Icon corresponding to the LAG group is created You have now completed th...

Страница 19: ...net cable s and power Verify that the Green LED is a solid green Run Sample Viewer It will take a few seconds for the camera to be recognized especially if your camera is in DHCP mode If the camera do...

Страница 20: ...s Use Cat5e or better cabling known to work Configure your NIC as outlined in Gigabit Ethernet Setup For Windows It should have an IP address of 169 254 x x Subnet Mask 255 255 0 0 This is the AutoIP...

Страница 21: ...be on the same subnet as your NIC Camera is not listed or flashing Camera Unavailable There may be multiple NICs on your system set to the same subnet The camera can not know which card to resolve to...

Страница 22: ...re or hardware trigger event to capture frames Packets are incoming but all dropping Be sure you have JumboFrames enabled on your NIC Otherwise decrease your PacketSize setting to 1500 All packets com...

Страница 23: ...GX1660 User Manual 70 0057A A Allied Vision Technologies Canada Inc 21 Addendum...

Страница 24: ...OGIC SYNC IN 1 180R 1 10W IF 5mA TLP281 4GB 1 2 16 15 TLP281 4GB 3 4 14 13 5V TO 24V IF 5mA VDD 3 3 442R 442R 5V TO 24V IF 5mA 100K SYNC OUT 4 CAMERA LOGIC SYNC OUT 4 D S G MMBF4393LT1G 3 3V LOGIC SYN...

Страница 25: ...NOTES 1 CAMERA POWER 5V TO 24V 2 CAMERA POWER DOES NOT NEED TO BE THE SAME AS USER VCC 3 CAMERA GND DOES NOT NEED TO CONNECT TO USER GND 4 USER VCC MUST HAVE CURRENT CAPACITY TO SUPPLY IC CURRENT FOR...

Страница 26: ...OM COMMON ZOOM FOCUS ZOOM FOCUS COMMON HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 TV ZOOM LENS UNIPOLAR TYPE ZOOM IRIS IRIS TV ZOOM LENS BIPOLAR TYPE HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 IRIS COMMON COMMON CO...

Страница 27: ...5 Video Iris Connection VIDEO SIGNAL LENS GROUND 12V POWER POWER GROUND VIDEO AUTO IRIS LENS 1 2 3 4 JEITA CONNECTOR 1 2 3 4 LENS POWER 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12S 1 2 3 4 5 6 7 8...

Страница 28: ...n Technologies Canada Inc 26 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency Interline Time Expose Start Delay Trigger Jitter Idle Register...

Страница 29: ...e and indicates when the next Exposure cycle can begin such that the Exposure will end after the current Readout o Interline Time is the time between sensor row readout cycles o Imaging is high when t...

Страница 30: ...the fastest triggering cycle time whereby the camera image sensor is exposing and reading out simultaneously then the User Trigger signal should be applied as soon as a valid Trigger Ready is detecte...

Страница 31: ...Disabled an external trigger does not control end of acquisition AcqRec An AcqStart hardware trigger signal or the AcquisitionStart command must be received before your AcqRec trigger See Acquisition...

Страница 32: ...g falling edge trigger EdgeAny rising or falling edge LevelHigh active high signal LevelLow active low signal FrameStartTriggerMode Determines how an image frame is initiated within an acquisition Fre...

Страница 33: ...before the AcqRec trigger event with AquisitionFrameCount minus RecorderPreEventCount images being returned after the trigger event Valid only when AcquisitionMode equals Recorder NOTE at least one i...

Страница 34: ...ureAutoTarget in which the autoexposure algorithm will not respond Can be used to limit exposure setting changes to only larger variations in scene lighting ExposureAutoAlg The following algorithms ca...

Страница 35: ...n variation from GainAutoTarget in which the auto gain algorithm will not respond Can be used to limit gain setting changes to only larger variations in scene lighting GainAutoMax In dB Sets the upper...

Страница 36: ...um driving voltage for closing the lens iris Typically this will be 150 however it may vary dependent on the lens reference voltage IrisVideoLevelMin In 10 mV units Limits the minimum driving voltage...

Страница 37: ...lly this parameter does not require adjustment HeartbeatTimeout In milliseconds The maximum amount of time the camera will wait for a heartbeat command before timing out NOTE this value may need to be...

Страница 38: ...opped StatPacketsDropped you will likely need to decrease this parameter StreamHold For controlling when the camera sends data to the host computer Normally the camera sends data to the host computer...

Страница 39: ...al number of bytes per image frame Dependant on ROI PixelFormat and Binning ImageMode Binning is the summing of charge of adjacent pixels on a sensor to give a lower resolution but more sensitive imag...

Страница 40: ...trigger FrameTrigger Active when an image has been initiated to start This is a logic trigger internal to the camera which is initiated by an external trigger or software trigger event Exposing Active...

Страница 41: ...filter driver is not installed or is not activated StatFilterVersion Version of the filter driver being used StatFrameRate The current actual frame rate of the camera as received by the driver StatFr...

Отзывы: