background image

A5 Installation and Safety Guide Cover

Rapier 48w Switch
Installation and Safety Guide

Содержание Rapier 48w

Страница 1: ...Rapier 48w Switch Installation and Safety Guide ...

Страница 2: ...or written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesis Inc has been advised of known or should have known th...

Страница 3: ...his Guide 4 Package Contents 4 Selecting a Site 5 Installing the Switch 6 Applying Power to the Switch 9 Connecting Data Cables to the Switch 12 Configuring the Switch 14 Checking LEDs 16 Documentation Set 18 Standards 19 Safety 20 Telecommunications Interfaces 21 ...

Страница 4: ...seller if any items are damaged or missing one serial cable for connecting the switch to a terminal or PC two 19inch rack mount brackets two 23inch rack mount brackets and eight M4 flat head screws for mounting the switch in a rack one grounding stud crimp terminal two M5 hex nuts with lock washers for connecting the switch to primary ground one 4 terminal DC connector plug MSTB with fixing screws...

Страница 5: ...ensing You need a reliable and earthed grounded power supply source preferably dedicated and filtered Switch ports suitable for connection to intra building or non exposed cabling are required Cabling must not be exposed to sources of electrical noise such as radio transmitters broadband amplifiers power lines electric motors and fluorescent fixtures Related network devices can be connected to the...

Страница 6: ...k mount brackets four rack mount screws and cage nuts if required a flat screwdriver for the captive screws on the fan units and the DC power connection a suitable spanner for tightening the nuts on the chassis grounding stud an appropriate DC power source DC supply cable ring connectors wire strippers and a PANDUIT Uni Die dieless crimping toolset Prepare the cabinet in a suitable location Follow...

Страница 7: ...this equipment must be earthed Rack mount the switch 1 Ensure the rack has sufficient space for the switch and its cables For the switch s requirements see Selecting a Site on page 5 2 Install cage nuts if required so they are ready for the rack mount screws in the following steps The Rapier 48w can be front center or rear mounted 3 Unpack the switch 4 Screw one bracket to each side of the switch ...

Страница 8: ...the fan unit out of its cage The internal power connection is quite solid so pull firmly on the captive screws 3 Insert the air filter into the narrow slot between the front grill of the fan unit and the fan Position the air filter with the plastic frame towards the fan and the pull tab to the top The air filter should fit snugly 4 Slide the fan unit back into its cage making sure that the air fil...

Страница 9: ...ment closets in accordance with Articles 110 16 110 17 and 110 18 of the National Electrical Code ANSI NFPA 70 Damage to equipment may result if power is connected improperly Before working on equipment that is connected to power remove jewellery including rings necklaces and watches Metal objects will heat up when connected between power and ground and can cause serious burns or weld the metal ob...

Страница 10: ...onnect the DC supplies To provide power supply resiliency the Rapier 48w switch can receive its DC power from either of two separate sources Each power source should supply 48V DC 40 to 60VDC to the switch When the switch is powered by centralized DC power use UL Listed Type TC tray cables to connect the equipment to the power sources Each tray cable should have two conductors in the range 14 to 1...

Страница 11: ... tray cable near the rack framework using multiple cable ties to minimize the chance of the connections being disturbed by casual contact with wiring Use at least four cable ties separated 10cm 4inches apart with the first one located within 15cm 6inches of the terminal block 7 Energise the DC power source to the switch The Fault LED should light for approximately 3 seconds as the switch runs inte...

Страница 12: ...faces only Type 2 or Type 4 ports as described in GR 1089 CORE Issue 4 and require isolation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring The management asyn intra building ports can only be directly connected to equipment within the same frame cabinet or line up and where the equipment ...

Страница 13: ... first release it by gently pulling the release lever then pull it out of the socket Never force a transceiver into or out of a socket WAN ports If you have installed an NSM connect the NSM ports to the WAN For more information see the Network Service Module Installation and Safety Guide and the Network Service Module Hardware Reference If you have installed an AR040 4 PIC NSM with PICs connect th...

Страница 14: ...rounded at both ends especially if permanently connected 2 Set the communication parameters Set the communication parameters on your terminal or terminal emulation program to Bit rate 9600 Data bits 8 Parity None Stop bits 1 Flow control Hardware For information about terminal emulation see Using Windows Terminal and HyperTerminal in the Hardware Reference 3 Log in at the prompt After the switch h...

Страница 15: ...les hlp 6 Configure the switch Refer to the Software Reference for more information about configuring the software Alternatively if you do not know the command syntax use any of the following to help you To display a list of help topics use the help command To display help on a specific topic use the help topic command To display a list of valid options type a question mark or press the Tab key at...

Страница 16: ...or management software is malfunctioning 1 flash A switch fan has failed POWER Green The switch is receiving power and the voltage is within the acceptable range Off The switch is not receiving power LED State Description SWAP Green The NSM and its PICs are ready to be hot swapped Off The Hot Swap button must be pressed before the NSM or its PICs can be hot swapped or the software version does not...

Страница 17: ...ink activity Amber 10 M Link established Flashing 10 M Link activity Off No link D C Green Full Duplex Flashing N A Amber Half Duplex Flashing Collisions Off No link LED State Description L A Green 1000 M Link established Flashing 1000 M Link activity Off No link SFP Amber SFP installed Flashing SFP installed but indicating a transmission fault Off No link ...

Страница 18: ...llation and Safety Guide which describes how to install a Network Service Module The Network Service Module Hardware Reference which contains detailed information on the hardware features of Network Service Modules The Port Interface Card Installation and Safety Guide which describes how to install a Port Interface Card The Port Interface Card Hardware Reference which contains detailed information...

Страница 19: ...on against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user...

Страница 20: ...ord CAUTION Air vents must not be blocked and must have free access to the room ambient air for cooling OPERATING TEMPERATURE This product is designed for a maximum ambient temperature of 50 degrees C CAUTION MECHANICAL LOADING Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven loading Lithium Battery Should only be changed by authorised s...

Страница 21: ...wires DC versions of this system will work with a positive grounded or negative grounded DC system Telecommunications Interfaces The following statements apply to Network Service Module NSM and Port Interface Card PIC expansion options for Wide Area Network WAN links Warning To reduce risk of fire use only No 26 awg or larger telecommunications line cord if the cord supplied is not used with the a...

Страница 22: ...operating conditions and under single fault conditions Under normal operating conditions the voltages do not exceed 42 4 V peak AC or 60 V DC TNV1 The following interfaces are Telecommunications Network Voltage TNV1 circuits which operate normally within the limits of SELV BRI ports for connection to ISDN Basic Rate telecommunications networks PRI ports for connection to ISDN Primary Rate telecomm...

Страница 23: ...equest that you disconnect the equipment until the problem is resolved This equipment cannot be used on public coin phone service provided by the telephone company Connection to party line service is subject to state tariffs Your telephone company may discontinue your service if your equipment causes harm to the telephone network They will notify you in advance of disconnection if possible During ...

Страница 24: ...ed by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This...