C613-50102-01 REV C
Command Reference for x510 Series
1962
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
V
IRTUAL
C
HASSIS
S
TACKING
(VCS
TACK
™) C
OMMANDS
SHOW
STACK
Related
Commands
stack disabled-master-monitoring
stack software-auto-synchronize
Priority
Stack member master election priority (between 0 and 255). Note
that the lowest number has the highest priority.
Role
Stack member’s role in the stack, this can be one of:
•
Active Master
•
Disabled Master
— this is the temporary master when there is a
communication break within the stack, but communication still
exists across the resiliency link. In this state all switch ports within
the stack are disabled by default, but a different configuration can
be run by a “type stack disabled-master” trigger.
•
Backup Member
— a device other than the stack master.
•
Provisioned
— indicates that the stack position is provisionally
configured, i.e. ready to accept a particular switch type into the
stack.
Table 3:
Parameters in the output from the
show stack
command (cont.)
Parameter
Description