AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide
25
Cable Specifications
Table 7 contains the cable specifications for the twisted pair ports.
Note
The twisted pair ports on the switch feature auto-MDI when
operating at 10, 100, or 1000 Mbps. A port is configured as MDI or
MDI-X when it is connected to an end node. Consequently, you can
use a straight-through twisted pair cable when connecting any type
of network device to a port on the switch.
Table 7. Twisted Pair Cabling and Distances
Speed
Type of Cable
Maximum
Operating
Distance
10 Mbps
Standard TIA/EIA 568-B-compliant
Category 3 or better shielded or
unshielded cabling with 100 ohm
impedance and a frequency of 16
MHz.
100 m (328 ft)
100 Mbps
Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.
100 m (328 ft)
1000 Mbps
Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.
100 m (328 ft)
Содержание AT-x210 Series
Страница 6: ...Contents iv ...
Страница 8: ...List of Figures vi ...
Страница 10: ...List of Tables viii ...
Страница 14: ...4 ...
Страница 30: ...Chapter 1 Overview 20 ...
Страница 56: ...Chapter 2 Installation 46 ...
Страница 60: ...Chapter 3 Troubleshooting 50 ...
Страница 61: ...AT x210 9GT AT x210 16GT and AT x210 24GT Switches Installation Guide 51 Appendix A Technical Specifications ...
Страница 66: ...Appendix A Technical Specifications 56 ...