AT-MS201 and AT-MS202 Installation Guide
11
Setting the DIP switch for Speed and Duplex Mode
1. Using the DIP switch, set the SPEED and DUPLEX modes for Port 1 (FX)
and Port 2 (UTP). The default for both ports is 100 Mbps, half duplex.
The operating speed for each UTP port is shown as follows:
Up = 10 Mbps (10Base-T)
Down = 100 Mbps (100Base-TX)
(The FX port is 100Mbs only.)
2. Set the DUPLEX mode for Port 1 and Port 2, as shown in the following:
Up = Half Duplex
Down = Full Duplex
3. Verify that the DIP switches are set to the desired configuration.
4. Press the RESET button to load your new configuration.
Note
Every time you change a DIP switch, make sure you press the RESET
button to load the new configuration.
5. Plug the opposite end of each 10/100Base-T or 100Base-TF cable into a
network node or workstation.
6. Verify that the LEDs indicate the correct configuration.
You are now ready to operate your AT-MS201/202 Micro Switch in a network
configuration. The switch supports a maximum of 8,192 MAC addresses in the
forwarding table.