AT-iMG2400 Series Installation Guide

27

Chapter 3

Turn-Up and Troubleshooting

Turn-up Sequence

The product is shipped with software already installed for the default configuration. For information on 
loading software, refer to the 

Allied Telesis Gateway Product Family Software Reference

, available from the Allied 

Telesis website at 

http://www.alliedtelesis.com/

. To configure a large numbers of units, consider using the 

AlliedView Network Management System (NMS).

Note

You can provision the iMG using the local command set. From the local terminal, download software 
drivers from the restricted Allied Telesis website, located at 

http://www.alliedtelesis.com/support/

software/restricted

.

1.

Ensure the UPS device has the battery connected so that the battery can provide power if necessary. The 
battery must be plugged in and charged.

2.

Turn on the power supply. (The PWR LED turns green.)

3.

The SYST LED turns red. Once the boot-up sequence is complete, the SYST LED is green.

4.

To override the configured settings and load the default configuration:

a.

Press and hold the reset button, power the unit on, and wait until the SYST LED goes orange. 
(around 10 seconds).

b.

Release the reset button.

c.

Wait while the SYST LED turns red (booting), then green (configuration file is loaded).

5.

The LEDs should now reflect normal activity, as shown in the following table. Refer to the 
Troubleshooting section if an LED is not in the expected state.

Note

After booting, if the DHCP server has been appropriately configured, the iMG may detect a software 
update. The SYST LED sequence will be 4Hz red while files are being downloaded and 2Hz red while 
files are being written to flash memory. This sequence may repeat if any other designated files are being 
updated. Once files are downloaded, the system will restart.

6.

To test the battery backup, unplug the UPS. If the iMG continues to function normally, reconnect the 
UPS. If the iMG loses power, replace the UPS and return to step 1.

Содержание AT-iMG2426F

Страница 1: ...613 001727 Rev D iMG2400 Series AT iMG2426F Installation Guide...

Страница 2: ...espective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein i...

Страница 3: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning...

Страница 4: ...Guide 4 Translated Safety Statements Important The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements on the Allied Telesis web sit...

Страница 5: ...ications 12 Power Cord Wiring 13 Local Management Connection 14 Chapter 2 Installing the Gateway 15 Outdoor Installation 15 Required Tools and Supplies 15 Step 1 Check Package Contents 15 Step 2 Exami...

Страница 6: ...UPS Configuration Recommended 17 Figure 5 Grounded UPS Configuration 18 Figure 6 Rear Connections 19 Figure 7 Slots for Connections 20 Figure 8 Snapping the gateway into the Enclosure 21 Figure 9 Plug...

Страница 7: ...AT iMG2400 Series Installation Guide 7 Tables Table 1 Gateway Terminal Block to Power Cord Terminal Block Wiring 13 Table 2 LEDs 28...

Страница 8: ...Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data Warning Warnings inform you that performing or omitting a specific action may result i...

Страница 9: ...rk on equipment or cables during periods of lightning activity Warning Class I equipment This equipment must be grounded The AC power plug must be connected to a properly wired earth ground socket out...

Страница 10: ...e iMG ground connection In this case it is imperative that the AT iMG008 AT iMG008NB UPS be used as it will prevent any ground loop currents from flowing between the iMG and the AC ground system Conta...

Страница 11: ...AT iMG2400 Series Installation Guide 11 Chapter 1 Technical Specifications Electronics Overview The AT iMG2400 series models provide six 10 100 1000T LAN ports Figure 1 AT iMG2426F Electronics Unit...

Страница 12: ...ved including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These...

Страница 13: ...0 cTUVus CSA C TICK CE Power Cord Wiring To wire the terminal block for the gateway to the terminal block for the power supply cord refer to Figure 2 and Table 1 Figure 2 Gateway Terminal Block to Pow...

Страница 14: ...ake your own cable we recommend 16 AWG wires Local Management Connection The MGMT port is a standard USB B for a Telnet connection LOW BATT 7 7 Table 1 Gateway Terminal Block to Power Cord Terminal Bl...

Страница 15: ...electronics unit and must be at least 1 meter long Note A jumper cable is not required but the fiber cable in the enclosure must have a UPC SC connector and be long enough to connect to the electronic...

Страница 16: ...such as using at least 6AWG copper for the ground wire Figure 3 Enclosure AT EN SFR ONT Ready for the Electronics Unit Step 3 Check Power and Grounding Battery Backup The electronics unit is designed...

Страница 17: ...19 Caution Run the iMG BOND wire to the AC service bonding point to avoid exposing the iMG to GND currents For example do not ground the iMG to a connecting wire between two ground rods Do not connect...

Страница 18: ...be verified to have a connection through the building AC wiring system to the BPG Caution This is acceptable only if required by local codes Note Wire from the UPS to the iMG must be kept short in th...

Страница 19: ...re there are two cable entrances The left entrance is for power grounding and the fiber cables The right is for all telephone and LAN cables Refer to Figure 7 Figure 6 Rear Connections Note Slot Place...

Страница 20: ...ts for Connections Snap the Unit into the Enclosure To install the gateway perform the following procedure 1 Open the enclosure door and locate the hinge points at the left side of the enclosure base...

Страница 21: ...he gateways For lengths up to 30 ft use wire with a minimum 18 AWG Figure 2 on page 13 provides a detailed wiring diagram To connect the power cord perform the following procedure 1 Note that the Encl...

Страница 22: ...r Jumper Cable Connect the fiber jumper cable from the Electronics In side of the SC fiber coupler to the WAN fiber port of the electronics unit Use the guides to ensure there are no crimps in the cab...

Страница 23: ...osing the unit use the hex pin security screwdriver to fasten the ground nut that is located below the ground symbol When this is tightened suggested maximum torque of 18 6 in lbs the unit is grounded...

Страница 24: ...and then seal the grommet with tape and silicone sealant 7 Plug the RJ11 connectors into the TEL ports of the electronics unit Primary Protector Requirements POTS Line For indoor or outdoor installat...

Страница 25: ...in the future 4 Connect the LAN cables to the RJ 45 ports on the gateway 5 Insert a UV rated wire tie through the bottom of the cable entrance 6 Secure the wires with a wire tie as shown in Figure 12...

Страница 26: ...nection of power cables fiber cables telephone wires and LAN cables is the same Using an indoor AC Power Supply Unit PSU with the iMG When the iMG is mounted indoors it may be powered with an approved...

Страница 27: ...green 3 The SYST LED turns red Once the boot up sequence is complete the SYST LED is green 4 To override the configured settings and load the default configuration a Press and hold the reset button po...

Страница 28: ...PWR ON The iMG is receiving power and the voltage is within the acceptable range OFF The unit is not receiving power SYST ON and Green System is working normally If LED is red the status can be ON Sy...

Страница 29: ...receiver on the connected telephone Solution 1 Verify that the telephone cable is correctly connected that the correct cable is being used and that the cable is not damaged Solution 2 Unplug the RJ 11...

Страница 30: ...ault cfg If problems still persist contact Allied Telesis Problem There is a problem with the telephone service Solution Check the following Swap out the cable for a known good cable For POTS phones a...

Отзывы: