background image

IMC2000/200 Series Media Converter Installation Guide

28

Speed/Duplex

Combinations for

AT-IMC2000

For speed/duplex interactions between the copper port on the 
AT-IMC2000 and the copper link partner, see Table 4 for allowable speed/
duplex combinations.

Table 4. Copper Connection Speed/Duplex and Resulting Speed - AT-IMC2000

AT-IMC2000 

Copper Port 

Speed/Duplex 

Setting

Copper Link Partner Port Setting

Auto Negotiation

100Mbps 
Force Full 
Duplex

100Mbps 
Force Half 
Duplex

1000Mbps 
Force Full 
Duplex*

Auto Negotiation 1000Mbps full 

duplex 
connection for 
Gigabit Link 
Partners

100Mbps full 
duplex 
connection for 
100Mbps Link 
Partners

Duplex 
mismatch – not 
supported

100Mbps half 
duplex 
connection

1000Mbps 
full duplex 
connection

100Mbps Full 
Duplex

Duplex 
mismatch – not 
supported

100Mbps full 
duplex 
connection

Duplex 
mismatch – 
not supported

No 
connection

*Although 1000Mbps connections require Auto Negotiation, some switches allow the 
option of only advertising 1000Mbps speed.

Note: The fiber port always runs at 1000Mbps full duplex.

Содержание AT-IMC2000T/SC

Страница 1: ...SED FORCE 100FD OFF ON TX RX AT IMC2000 Industrial Media Converter PORT 1 PORT 2 SYSTEM 1 2 3 SML NOT USED FORCE 100FD OFF ON TX RX AT IMC200 Industrial Media Converter PORT 1 PORT 2 SYSTEM 1 2 3 OFF...

Страница 2: ...espective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein i...

Страница 3: ...ent is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harm...

Страница 4: ...h case the user may be required to take adequate measures E84 EMC Immunity EN55024 EN55035 EN61000 3 2 EN61000 3 3 Electrical Safety EN60950 1 TUV UL 60950 1 CULUS Warning Laser Safety EN60825 L7 Tran...

Страница 5: ...tallation 27 Cable Specifications for Copper Port 27 Speed Duplex Combinations for AT IMC2000 28 Speed Duplex Combinations for AT IMC200 29 Unpacking the Media Converter 30 Installing the Media Conver...

Страница 6: ...IMC2000 200 Sereis Media Converter Installation Guide 6 Using a Swab 56...

Страница 7: ...s for the following Industrial Switching Media Converters AT IMC2000TP SP AT IMC2000TP SC AT IMC2000T SP AT IMC2000T SC AT IMC200TP SC AT IMC200T SC This preface contains the following sections Symbol...

Страница 8: ...information Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data Warning Warnings inform you that performing or omitting a specific...

Страница 9: ...andise Authorizations RMAs and contact Allied Telesis technical experts USA and EMEA phone support Select the phone number that best fits your location and customer type Hardware warranty information...

Страница 10: ...IMC2000 200 Series Media Converter Installation Guide 10...

Страница 11: ...11 Chapter 1 Overview This chapter contains the following sections Description on page 12 LEDs on page 16 Smart MissingLink SML on page 18...

Страница 12: ...re 1 AT IMC2000T SP Media Converter Key Features The IMC2000 200 series media converter has the following key features Tolerance to harsh industrial environments See Environmental Specifications on pa...

Страница 13: ...DI MDI X The twisted pair port automatically determines the configuration of the port on the device to which it is connected and then configures itself appropriately For example if a port on a media c...

Страница 14: ...her models DC Power The IMC2000 200 series media converter is equipped with the DC power connector Twisted Pair Port The twisted pair port features an eight pin RJ45 connector that uses four pins at 1...

Страница 15: ...ons is likely to cause a duplex mismatch in turn causing poor network performance 100 Mbps full duplex mode should only be used when the link partner is already forced to 100 Mbps full duplex operatio...

Страница 16: ...ure 3 LEDs on the AT IMC2000TP SP Media Converter Figure 4 shows the LEDs on the AT IMC2000T SC media converter Figure 4 LEDs on the AT IMC2000T SC Media Converter Copper Port PoE Fiber Port SYSTEM Co...

Страница 17: ...e on the copper port or the remote fiber port when operating in a back to back configuration with another IMC2000 200 Series media converter Copper Port L A Link Activity Off The port has not establis...

Страница 18: ...e is notified that the data path has been compromised and immediate action is required For example if the network connection to the media converter s twisted pair port fails the FIBER P2 L A LED blink...

Страница 19: ...onverter and end node L A LED behavior with SML enabled with a copper connection down between a media converter and an end node Figure 9 SML with Copper Connection to End Node Down IMC2000 200 Copper...

Страница 20: ...re 10 SML with Fiber Connection Between Media Converters Down Enabling SML To enable SML on the unit set the SML ON OFF DIP switch 1 to the ON position See Figure 2 on page 14 IMC2000 200 End Node Lin...

Страница 21: ...supported Warning To reduce the risk of electric shock the PoE ports on this product must not connect to cabling that is routed outside the building where this device is located E40 Enabling Remote P...

Страница 22: ...IMC2000 200 Series Media Converter Installation Guide 22...

Страница 23: ...nverter on page 26 Planning the Installation on page 27 Unpacking the Media Converter on page 30 Installing the Media Converter on page 32 Installing the Media Converter on a DIN Rail on page 33 Insta...

Страница 24: ...Air vents must not be blocked and must have free access to the room ambient air for cooling E6 Note All Countries Install product in accordance with local and National Electrical Codes E8 Note The po...

Страница 25: ...ransceiver can be damaged by static electricity Be sure to observe all standard electrostatic discharge ESD precautions such as wearing an antistatic wrist strap to avoid damaging the transceiver E86...

Страница 26: ...ports on the front of the media converter This will make it easier for you to connect and disconnect cables as well as view the media converter s LEDs Air flow around the unit and through its vents o...

Страница 27: ...UTP network cabling to a fiber optic cabling which allows two network devices such as a network adapter card repeater switch media converter router camera or access point across long distances The twi...

Страница 28: ...ion 100Mbps Force Full Duplex 100Mbps Force Half Duplex 1000Mbps Force Full Duplex Auto Negotiation 1000Mbps full duplex connection for Gigabit Link Partners 100Mbps full duplex connection for 100Mbps...

Страница 29: ...erter For the fiber optic port specifications refer to Fiber Optic Port Specifications on page 52 Table 5 Copper Connection Speed Duplex and Resulting Speed AT IMC200 AT IMC200 Copper Port Speed Duple...

Страница 30: ...tion You must use the original shipping material if you need to return the unit to Allied Telesis 2 Place the media converter on a level secure surface 3 Verify that the hardware components are includ...

Страница 31: ...unt kit separately One fiber port dust cover pre installed For AT IMC200xTP SC and AT IMC200xT SC models only One SFP slot dust cover pre installed For AT IMC2000TP SP and AT IMC2000T SP models only T...

Страница 32: ...the media converter on a desktop on a DIN rail or on a wall Perform one of the following procedures To install the media converter on a DIN rail see Installing the Media Converter on a DIN Rail on pa...

Страница 33: ...DIN rail perform the following procedure 1 Take the media converter See Figure 11 Figure 11 The Media Converter with the Bracket Attached 2 Hook the top of the bracket on the upper side of the DIN ra...

Страница 34: ...IMC2000 200 Series Media Converter Installation Guide 34 3 Ensure that the media converter unit is attached securely to the DIN rail See Figure 13 Figure 13 Securing the Media Converter to a DIN Rail...

Страница 35: ...converter on a wail perform the following procedure 1 Use a pencil or pen to mark the wall with two screw locations in the openings of your DIN rail See Figure 14 Figure 14 Marking the Wall for Screw...

Страница 36: ...lling the Holes on the Wall 3 Insert two metal anchors into the holes you drilled in Step 2 Figure 16 Pre drilling Holes 4 Align the openings in the piece of the DIN rail to the metal anchors on the w...

Страница 37: ...ch the piece of the DIN rail to the wall 6 Hook the top of the bracket on the upper side of the piece of the DIN rail and snap down the media converter unit as shown in Figure 12 on page 33 7 Ensure t...

Страница 38: ...install the transceiver before connecting the fiber optic cable to it 1 Remove the transceiver from its shipping container and store the packaging material in a safe location Warning An SFP transceive...

Страница 39: ...ecures the transceiver and prevents it from being dislodged from the slot Figure 21 Positioning the SFP Handle in the Upright Position Note SFP transceivers are dust sensitive Always keep the plug in...

Страница 40: ...IMC2000 200 Series Media Converter Installation Guide 40 For information on the cable specifications of the SFP consult the documentation shipped with the SFP...

Страница 41: ...41 Chapter 3 Powering On the Media Converter This chapter contains the following procedures Wiring and Powering on the Media Converter on page 42...

Страница 42: ...n in Figure 22 Figure 22 Locating the Terminals on the DC Terminal Block 2 Before you strip and attach the wires review the following safety precautions Warning For centralized DC power connection ins...

Страница 43: ...e 23 Stripped Wire 4 Connect the negative feed wire to the terminal marked V negative by inserting the wire into the terminal block and tightening the connection with a flathead screwdriver SeeFigure...

Страница 44: ...of the connections being disturbed by casual contact with the wiring Allied Telesis recommends that you use at least four cable ties 10 centimeters 4 inches apart with the first one located within 15...

Страница 45: ...wer source is within the required levels for the AT IMC2000 200 series media converter Solution An internal component on the unit is damaged or not working properly Try the following Power cycling the...

Страница 46: ...twisted pair cable does not exceed 100 meters 328 feet Verify that the end node connected to the media converter is operating at the same speed Verify that you are using the appropriate category of tw...

Страница 47: ...the port is able to establish a link then the problem is with the cable or with the other end node If the remote end node is a management device use its management firmware to determine whether its po...

Страница 48: ...IMC2000 200 Series Media Converter Installation Guide 48...

Страница 49: ...Optic Port Specifications on page 52 Physical Specifications Environmental Specifications Table 8 Physical Specifications Dimensions W x D x H 50 8 mm x 99 1 mm x 20 3 mm 2 0 in x 3 9 in x 0 8 in Weig...

Страница 50: ...11 shows power specifications for the AT IMC2000T SP AT IMC2000T SC and AT IMC200T SC models RJ45 Connector and Port Pinouts Figure 25 illustrates the pin layout for the RJ45 connector and port Figure...

Страница 51: ...X configuration at 10 or 100 Mbps Table 14 lists the pin signals when a port is operating at 1000 Mbps Table 12 MDI Pin Signals 10 or 100 Mbps Pin Signal 1 TX 2 TX 3 RX 6 RX Table 13 MDI X Pin Signals...

Страница 52: ...ower Budget Min Max Min Sensitivity Max Overload FDDI 62 5 125 um 220 m 9 5 dBm 4 0 dBm 20 dBm 3 dBm 10 5 dBm OM1 62 5 125 um 275 m OM2 50 125 um 550 m 1 For reference only actual distance is dependen...

Страница 53: ...er The end of the fiber optic cable is held in the core of the ferrule in the plug Light signals are transmitted through the core of the fiber Even minor smudges or dirt on the end face of the fiber c...

Страница 54: ...t use compressed air or aerosol air to clean a fiber optic connector To clean a fiber optic connector using a cartridge cleaner perform the following procedure 1 With one hand hold the cartridge clean...

Страница 55: ...ule tip when you reach the bottom of the cleaning surface can result in static electricity that can damage the fiber optic cable E82 4 If desired repeat Step 2 and Step 3 5 If a fiber inspection scope...

Страница 56: ...ferrule tips These swabs often referred to as lint free or alcohol free swabs shown in Figure 30 are available from many vendors Stick cleaners are available in both 2 5 mm and 1 25 mm sizes for use o...

Страница 57: ...2 If desired repeat Step 1 3 If a fiber inspection scope is available use the scope to inspect the connector to make sure that it is clean and to check for scratches pits or other problems that may a...

Страница 58: ...IMC2000 200 Series Media Converter Installation Guide 58...

Отзывы: