SMTP Configuration interface
Having ticked the
Syslog/SMTP
checkboxes, the event log/email alert will be sent to the system log
server and the SMTP server respectively. Also, Port event log/alert (link up, link down, and both) can
be sent to the system log server/SMTP server respectively by setting the trigger condition.
System event selection
•
: There are 4 event types—Device Cold Start, Device Warm Start,
Authentication Failure, and X-ring Topology Change. The checkboxes are not available for ticking
unless the
Syslog Client Mode
on the Syslog Configuration tab and the
E-mail Alert
on the
SMTP Configuration tab are enabled first.
Device cold start
: W
hen the device executes cold start action, the system will issue the event log/
email alert to the system log/SMTP server respectively.
Device warm star
t:
When the device executes warm start, the system will issue the event log/email
alert to the system log/SMTP server respectively.
Authentication Failure
:
When the SNMP authentication fails, the system will issue the event log/
email alert to the system log/SMTP server respectively.
X-ring topology change
:
When the X-ring topology has changed, the system will issue the event
log/email alert to the system log/SMTP server respectively.