Allied Telesis AT-IFS802SP/POE Скачать руководство пользователя страница 1

613-001691 Rev.A 

AT-IFS802SP/POE 

8x10/100TX POE Layer 2 Managed Industrial Switch

AT-IFS802SP/POE Installation and
User’s Guide

Содержание AT-IFS802SP/POE

Страница 1: ...613 001691 Rev A AT IFS802SP POE 8x10 100TX POE Layer 2 Managed Industrial Switch AT IFS802SP POE Installation and User s Guide ...

Страница 2: ...respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits ari...

Страница 3: ... when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct th...

Страница 4: ...4 ...

Страница 5: ...nteractive support center to search for answers to your questions in our knowledge database check support tickets learn about RMAs and contact Allied Telesis technical experts USA and EMEA phone support Select the phone number that best fits your location and customer type Hardware warranty information Learn about Allied Telesis warranties and register your product online Replacement Services Subm...

Страница 6: ...Preface 6 ...

Страница 7: ...Application 21 4 3 Dual Homing Application 22 Chapter 5 Console Management 23 5 1 Connecting to the Console Port 23 5 2 Pin Assignment 23 5 3 Login in the Console Interface 24 5 4 CLI Management 24 5 5 Commands Level 25 Chapter 6 Web Based Management 26 6 1 About Web based Management 26 6 2 Preparing for Web Management 26 6 3 System Login 26 6 4 System Information 27 6 5 IP Configuration 28 6 6 DH...

Страница 8: ...nfiguration 58 6 20 3 SNMPV3 Configuration 59 6 21 QoS Configuration 60 6 21 1 QoS Policy and Priority Type 60 6 21 2 Port based Priority 61 6 21 3 COS Configuration 62 6 21 4 TOS Configuration 62 6 22 IGMP Configuration 62 6 23 X Ring 63 6 24 LLDP Configuration 65 6 25 Security 802 1X Radius Configuration 65 6 25 1 System Configuration 65 6 25 2 Port Configuration 66 6 25 3 Misc Configuration 67 ...

Страница 9: ...mands Set 88 IGMP Commands Set 89 Multicast Filtering Commands Set 90 LLDP Commands Set 90 Mac Filter Table Commands Set 90 SNMP Commands Set 91 Port Mirroring Commands Set 93 802 1x Commands Set 94 TFTP Commands Set 96 SystemLog SMTP and Event Commands Set 97 Fault Relay Alarm Commands Set 98 SNTP Commands Set 99 X ring Commands Set 100 PoE Commands Set 101 ...

Страница 10: ...EE 802 3u 100Base TX FX IEEE802 3ab 1000Base T IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 3af Power over Ethernet IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1QVLAN Tag IEEE 802 1x User Authentication Radius IEEE802 1ab LLDP Switch Architecture Back plane Switching Fabric 5 6Gbps Packet...

Страница 11: ...to 32 dBm Single mode 34 to 30 dBm Multi mode PoE pin assignment RJ 45 port 1 8 support IEEE 802 3af End point Alternative A mode Per port provides 15 4W ability Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 Protocol CSMA CD LED Per unit Power Green Power 1 Green Power 2 Green Fault Red Master Green FWD Green 8 port 10 100 Link Activity Green Full duplex Collision Amber SFP port LNK ACT Gr...

Страница 12: ...ckup feature and the recovery time below 20ms Quality of Service The quality of service determined by port Tag and IPv4 Type of service IPv4 Different Service Class of Service Supports IEEE802 1p class of service per port provides 4 priority queues Port Security Supports 100 entries of MAC address for static MAC and another 100 for MAC filter Port Mirror Supports 3 mirroring types RX TX and Both p...

Страница 13: ...nt carry ability 1A DC24V SNMP Trap 1 Cold start 2 Link up down 3 X Ring topology changed 4 Authorization fail 5 PD disconnect trap PoE port event DHCP Provides DHCP Client DHCP Server Port and IP Binding DNS Provides DNS client feature and supports Primary and Secondary DNS server SNTP Supports SNTP to synchronize system clock in Internet Firmware Update Supports TFTP firmware update TFTP backup ...

Страница 14: ...tch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension 8 10 100TX w X Ring Managed Industrial Switch dimension W x D x H is 72mm x 105mm x 152mm 2 2 Front Panel The Front Panel of the 8 10 100TX w X Ring Managed Industrial Switch is shown as below Front Panel of the industrial switch ...

Страница 15: ...OE W 80 User Manual 2 3 BottomView The bottom panel of the 8 10 100TX w X Ring Managed Industrial Switch has one terminal block connector of two DC power inputs and one fault alarm Bottom Panel of the industrial switch ...

Страница 16: ... On Power or port failure Off No failure P9 P10 RJ 45 Green Upper LED On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached Green Lower LED On 1000M Off 10 100M Link Active P9 P10 SFP Green On The SFP port is linking Blinks The port is transmitting or receiving packets from the TX device Off No device attached P1 P8 Green O...

Страница 17: ...ing the Power Inputs section for knowing 4 the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights Prepare the twisted pair straight through Category 5 cable for Ethernet connection 5 sert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and 6 anoth...

Страница 18: ... industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch 1 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To remove the industrial switch from the track reverse above steps ...

Страница 19: ... the industrial switch loose the screws to remove the DIN Rail 1 Place the wall mount plate on the rear panel of the industrial switch 2 Use the screws to screw the wall mount plate on the industrial switch 3 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 4 To remove the wall mount plate reverse the above steps 5 ...

Страница 20: ...e steps below to insert the power wire Insert AC or DC power wires into the contacts 1 and 2 for power 1 or 5 and 6 for power 1 Tighten the wire clamp screws for preventing the wires from loosing 2 note The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Страница 21: ...rting the wires the switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Insert the wires into the fault alarm contacts note The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Страница 22: ...FP slots supporting dual mode can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper multi mode or single mode fiber according to the transceiver With fiber optic it transmits at speed up to 1000 Mbps and you can prevent noise i...

Страница 23: ...rst press the upper side of the LC connector to release from the transceiver and pull it out Second push down the metal loop and pull the transceiver out by the plastic handle Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver Pull out from the transceiver Remove LC connector ...

Страница 24: ... the industrial switch is shown as below 4 1 X Ring Application The industrial switch supports the X Ring protocol that can help the network system to recovery from network connection failure within 20ms or less and make the network system more reliable The X Ring algorithm is similar to spanning tree protocol STP algorithm but its recovery time is faster than STP The following figure is a sample ...

Страница 25: ... the network it may have more than one X Ring group By using the coupling ring function it can connect each X Ring for the redundant backup It can ensure the transmissions between two ring groups not to fail The following figure is a sample of coupling ring application ...

Страница 26: ...nd upper level core switch Assign two ports to be the Dual Homing port that is backup port in the X Ring group The Dual Homing function only works when the X Ring function is active Each X Ring group only has one Dual Homing port note In Dual Homing application architecture the upper level switches need to enable the Rapid Spanning Tree protocol ...

Страница 27: ...is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program 5 2 Pin Assignment DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brown White NC 8 Brown ...

Страница 28: ...hed the parameter settings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in manager default value for Username and friend for Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen 5 4 CLI Management The system supports the console management CLI command After you log ...

Страница 29: ...e configuration Global Configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to configure those parameters that are going to be applied to your switch VLAN database Enter the vlan database command while in privileged EXEC mode switch vlan To exit to user EXEC mode enter exit Use this mode to configureVL...

Страница 30: ... such as Microsoft Internet Explorer TheWeb Based Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen 6 2 Preparing for Web Management Before using the web management install the industrial switch on the network and make sure that any one of the PCs on the ne...

Страница 31: ...identify the switch The version table below is a read only field to show the basic information of the switch System Name Assign the system name of the switch The maximum length is 64 bytes System Description Describes the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization FirmwareVersion Displays...

Страница 32: ...nd the new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabled this switch is configured as a DHCP client The network DHCP server will assign the IP address to the switch and display it in this column The default IP is 192 168 16 1 or the user has to assign an IP address manually when DHCP Client is disabled Subnet Mask Assign the sub...

Страница 33: ...red as a DHCP server 6 6 1 System configuration DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Low IP Address Type in an IP address Low IP address is the beginning of the dynamic IP range For example dynamic IP is in the range between 192 168 1 100 192 168 1 200 In contrast 192 168 1 100 is the Low IP address High IP Address T...

Страница 34: ... device the IP assigning type status and lease time DHCP Client Entries interface 6 6 3 Port and IP Bindings Assign the dynamic IP address bound with the port to the connected client The user is allowed to fill each port column with one particular IP address When the device is connecting to the port and asks for IP assigning the system will assign the IP address bound with the port Port and IP Bin...

Страница 35: ...are File Name Type in the name of the firmware image file to be updated Click 6 7 1 Update Firmware Apply Update Firmware interface Restore Configuration interface You can restore a previous backup configuration from theTFTP server to recover the settings Before doing that you must locate the image file on the TFTP server first and the switch will download back the flash image TFTP Server IP Addre...

Страница 36: ...There are five types of event Device Cold Start Device Warm Start Authentication Failure X Ring Topology Change and Port Event available to be issued as the event log Syslog Client Mode Select the system log mode Client Only Server Only or Both Client Only means the system event log will only be sent to this interface of the switch but on the other hand Server Only means the system log will only b...

Страница 37: ...sending the e mail alert to the SMTP server when the events occur SMTP Server IP Assign the mail server IP address when Email Alert is enabled this function will then be available Sender Type in an alias of the switch in complete email address format e g switch101 123 com to identify where the e mail alert comes from Authentication Having ticked this checkbox the mail account password and confirm ...

Страница 38: ...ient Mode on the Syslog Configuration tab and the E mail Alert on the SMTP Configuration tab are enabled first Device cold start When the device executes cold start action the system will issue the event log email alert to the system log SMTP server respectively Device warm start When the device executes warm start the system will issue the event log email alert to the system log SMTP server respe...

Страница 39: ...se drop down menu items have 3 selections Link UP Link Down and Link UP Link Down Disable means no event will be sent to the system log SMTP server Link UP The system will only issue a log message when the link up event of the port occurs Link Down The system will only issue a log message when the link down event of port occurs Link UP Link Down The system will issue a log message at the time when...

Страница 40: ...enable the function of lighting up FAULT LED on the panel when Ports states are link down or broken Fault Relay Alarm interface 6 10 SNTP Configuration SNTP Simple NetworkTime Protocol is a simplified version of NTP which is an Internet protocol used to synchronize the clocks of computers to some time reference Because time usually just advances the time on different node stations will be differen...

Страница 41: ... am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 1...

Страница 42: ...n the format of YYYYMMDD and HH MM leave a space between YYYYMMDD and HH MM YYYYMMDD an eight digit year month day specification HH MM a five digit including a colon mark hour minute specification For example key in 20070701 02 00 and 20071104 02 04 in the two column fields respectively to represent that DST begins at 2 00 a m on March 11 2007 and ends at 2 00 a m on November 4 2007 Daylight Savin...

Страница 43: ...ked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via HTTP service Enable Telnet Server Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via telnet ser...

Страница 44: ... of connection to the port Link The status of linking Up or Down State It s set by Port Control When the state is disabled the port will not transmit or receive any packet Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 octets oversize CRC Align errors fragments and jabbers packets via this p...

Страница 45: ...Force When the Negotiation column is set as Auto this column is read only Duplex It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only Flow Control Whether or not the receiving node sends feedback to the sending node is determined by this item When enabled once the device exceeds the input data rate of another ...

Страница 46: ...which is used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP peer of the trunk group Group ID There are 13 trunk groups to be selected Assign the Group ID to the trunk group LACP When enabled the trunk group is using LACP A port which joins an LACP trunk group has to make an agreement with its member ports first Please notic...

Страница 47: ...er of work ports must equal the total number of group member ports Select the ports to join the trunk group The system allows a maximum of four ports to be aggregated in a trunk group Click and the ports focused in the right side will be shifted to the left side To remove unwanted ports select the ports and click When LACP enabled you can configure LACP Active Passive status for each port on the S...

Страница 48: ...roup information on the tab of Aggregator Information 6 15 2 Aggregator Information Assigning 2 ports to a trunk group with LACP disabled Static Trunking Group information Group Key This is a read only column field that displays the trunk group ID Port Member This is a read only column field that displays the members of this static trunk group ...

Страница 49: ...nk group The default is 1 Select a 2 trunk group ID by pull down the drop down menu bar Enable LACP 3 Include the member ports by clicking the 4 Add button after selecting the port number and the column field of Work Ports changes automatically Switch 1 configuration interface Aggregation Information of Switch 1 5 Click on the tab of Aggregator Information to check the trunked group information as...

Страница 50: ... a trunk group ID by pull down the drop down menu bar 3 Enable LACP 4 Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically 5 Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches configured ...

Страница 51: ...e port state activity will change to Passive Active The port automatically sends LACP protocol packets Passive The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device 6 15 3 State Activity Apply note A link having two passive LACP nodes will not perform dynamic LACP trunk because both ports are waiting for an LACP p...

Страница 52: ...t can be selected to be destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traffic only and the other one forTX traffic only User can connect mirror port to LAN analyzer or Netxray Source Port The ports that user wants to monitor All monitored port traffic will be copied to mirror destination port User can select mult...

Страница 53: ...Multicast and Broadcast only types are only for ingress frames The egress rate only supports All type Rate Limiting interface All the ports support port ingress and egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate is 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate Ingress Enter the port ...

Страница 54: ...interface A port basedVLAN basically consists of its members ports which means theVLAN is created by grouping the selected ports This method provides the convenience for users to configure a simple VLAN easily without complicated steps Packets can go among only members of the sameVLAN group Note all unselected ports are treated as belonging to another singleVLAN If the port based VLAN enabled the ...

Страница 55: ...he maximumVLAN groups are up to 64 VLAN Port Based interface Add Apply Enter the group name and VLAN ID Add the selected port number into the right field to group these members to be a VLAN group or remove any of them listed in the right field from theVLAN And then click to have the configuration take effect You will see theVLAN list displays VLAN Port Based Add interface Apply ...

Страница 56: ...N ID is in the range of number between 1 and 4094 The amount of VLAN groups is up to 256 including defaultVLAN that cannot be deleted Each member port of 802 1Q is on either an Access Link VLAN tagged or a Trunk Link no VLAN tagged All frames on anAccess Link carry noVLAN identification Conversely all frames on a Trunk Link areVLAN tagged Besides there is the third mode Hybrid A Hybrid Link can ca...

Страница 57: ... Access Link A segment which provides the link path for one or more stations to the VLAN aware device An Access Port untagged port connected to the access link has an untagged VID also called PVID After an untagged frame gets into the access port the switch will insert a four byte tag in the frame The contents of the last 12 bit of the tag is untaggedVID When this frame is sent out through any of ...

Страница 58: ...to a trunk hybrid port of the other switch Both the taggedVID of the two ports have to be the same Untagged VID This column field is available when Link Type is set as Access Link and Hybrid Link Assign a number in the range between 1 an 4094 Tagged VID This column field is available when Link Type is set as Trunk Link and Hybrid Link Assign a number in the range between 1 an 4094 Click to have th...

Страница 59: ...rity 0 61440 The switch with the lowest value has the highest priority and is selected as the root If the value is changed the user must reboot the switch The value must be a multiple of 4096 according to the protocol standard rule Max Age 6 40 The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value betw...

Страница 60: ... 0 and 240 The value of priority must be the multiple of 16 Admin P2P The rapid state transitions possible within RSTP are dependent upon whether the port concerned can only be connected to exactly another bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link...

Страница 61: ...es implementing SNMP Community Strings Here you can define the new community string set and remove the unwanted community string String Fill the name string RO Read only Enables requests accompanied by this community string to display MIB object information RW Read write Enables requests accompanied by this community string to display MIB object information and to set MIB objects Click To remove t...

Страница 62: ...r is defined no traps will be issued To define a management station as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version IP Address Enter the IP address of the trap manager Community Enter the community string for the trap station TrapVersion Select the SNMP trap version type v1 or v2c Click To remove the community string select the community str...

Страница 63: ... name Authentication Password set up the authentication password Privacy Password set up the private password Click to add context name Click to remove unwanted context name Group Table Configure SNMP v3 group table Security Name User ID assign the user name that you have set up in user table Group Name set up the group name Click to add context name Click to remove unwanted context name 6 20 3 SN...

Страница 64: ...performance to a data flow QoS guarantees are important if the network capacity is insufficient especially for real time streaming multimedia applications such as voice over IP orVideoTeleconferencing since these often require fixed bit rate and are delay sensitive and in networks where the capacity is a limited resource for example in cellular data communication In the absence of network congesti...

Страница 65: ...elected Click to have the configuration take effect Click to have the configuration take effect Apply Configure the priority level for each port With the drop down selection item of Priority Type above being selected as Port based this control item will then be available to set the queuing policy for each port Port x Each port has 4 priority levels High Middle Low and Lowest to be chosen Click to ...

Страница 66: ...h the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority Click to have the configuration take effect 6 21 4 TOS Configuration Apply 6 22 IGMP Configuration The Internet Group Management Protocol IGMP is an internal protocol of the Internet Protocol IP suite IP manages multicast...

Страница 67: ...e blocked called backup port and another port is called working port Other switches in the X Ring group are called working switches and their two member ports are called working ports When the failure of network connection occurs the backup port of the master switch Ring Master will automatically become a working port to recover from the failure The switch supports the function and interface for s...

Страница 68: ...uple Port Assign the member port which is connected to the other ring group Control Port When the Enable Couple Ring checkbox is ticked you have to assign the control port to form a couple ring group between the two X rings Enable Dual Ring When this check box is ticked the Enable Ring Master check box will then also be enabled by the system which means this equipment is assigned as the Ring Maste...

Страница 69: ... nodes Click Apply LLDP Interface 6 25 Security 802 1X Radius Configuration 802 1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority like the user name and password that are verified by an authentication server such as RADIUS server After enabling the IEEE 802 1X function you can configure the parame...

Страница 70: ...n the unauthorized state Accept The specified port is required to be held in the authorized state Authorize The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable When disabled the specified port works without complying with 802 1x protocol Click 6 25 2 Port Configur...

Страница 71: ...ut before authentication fails and the authentication session ends Reauth period Set the period of time which clients connected must be re authenticated Click 6 25 3 Misc Configuration Apply 802 1x Misc Configuration interface 6 26 MAC AddressTable Use the MAC address table to ensure the port security You can add a static MAC address that remains in the switch s address table regardless of whether...

Страница 72: ...device network activity Port No Pull down the selection menu to select the port number Click If you want to delete the MAC address from filtering table select the MAC address and click Apply Delete Static MAC Addresses interface By filtering MAC address the switch can easily filter the pre configured MAC address and reduce the un safety You can add and delete filtering MAC address 6 26 2 MAC Filte...

Страница 73: ...similar to broadcasts they are sent to all end stations on a LAN or VLAN Multicast filtering is the function which end stations can receive the multicast traffic if the connected ports had been included in the specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to the registered end stations IP Address Assign a multicast...

Страница 74: ...70 AT IFS802SP POE W 80 User Manual Multicast Filtering interface ...

Страница 75: ...e maximum total power available for PDs AC Disconnect Tick this checkbox to monitor the AC impedance on the port terminals and removes power when the impedance rises above a certain value for a certain period for details see the IEEE 802 3af specification Capacitive Detection If the port and capacitive detection are enabled the capacitances state reads in the voltage result from the constant curre...

Страница 76: ...acy power devices Priority Pull down the selection menu item to choose the priority of power supplying Port Limit 15400 mW User can key in the power limit value which is under 15 4 Watts Mode Displays the operating mode of the port Current mA Displays the operating current of the port Voltage V Displays the operating voltage of the port Power mW Displays the power consumption of the port Determine...

Страница 77: ...actory Default interface 6 29 Save Configuration Save all configurations that you have made in the system To ensure the all configuration will be saved Click to save the all configuration to the flash memory Save Flash Save Configuration interface 6 30 System Reboot Reboot the switch in software reset Click to reboot the system Reboot System Reboot interface ...

Страница 78: ...o be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in you may hav...

Страница 79: ...ssover cable schematic 10 100BASE TX Pin outs With10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx note and signs represent the polarity of the wires that make up each wire pair Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data mi...

Страница 80: ...Base TX Cable Schematic The following two figures show the 10 100Base TX cable schematic Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs ...

Страница 81: ...77 AT IFS802SP POE W 80 User Manual 10 100 1000Base TX Cable Schematic Straight through cables schematic Cross over cables schematic ...

Страница 82: ...co non 802 3af standard PD Pin Signal Name 1 RX 2 RX 3 TX 4 VCC 5 VCC 6 TX 7 VCC 8 VCC Pin out of PoE Midspan Hub Switch Pin Signal Name 1 TX VCC 2 TX VCC 3 TX VCC 4 5 6 TX VCC 7 8 Pin out of PoE Endspan Hub Switch note and signs represent the polarity of the wires that make up each wire pair Before you power PD please check the RJ 45 connector pin assignment follow IEEE802 3af standard otherwise ...

Страница 83: ... description System Description G Set switch system description string switch config system description xxx system contact System Contact G Set switch system contact window string switch config system contact xxx show system info E Show system information switch show system info ip address Ip address Subnet mask Gateway G Configure the IP address of switch switch config ip address 192 168 1 1 255 ...

Страница 84: ...1 dhcpserver ipbinding IP address I Set static IP for DHCP clients by port switch config interface fastEthernet 2 switch config dhcpserver ipbinding 192 168 1 1 show dhcpserver configuration P Show configuration of DHCP server switch show dhcpserver configuration show dhcpserver clients P Show client entries of DHCP server switch show dhcpserver clients show dhcpserver ip binding P Show IP Binding...

Страница 85: ...config interface fastEthernet 2 switch config if no security bandwidth type all I Set interface ingress limit frame type to accept all frame switch config interface fastEthernet 2 switch config if bandwidth type all bandwidth type broadcast multicast flooded unicast I Set interface ingress limit frame type to accept broadcast multicast and flooded unicast frame switch config interface fastEthernet...

Страница 86: ...r Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configuration I show interface configuration status switch config interface fastEthernet 2 switch config if show interface configuration show interface status I show interface actual status switch config interface fastEthernet 2 switch confi...

Страница 87: ...t be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4 lacp workp 2 or switch config aggregator group 2 1 4 3 lacp workp 3 aggregator group GroupID Port list nolacp G Assign a static trunk group GroupID 1 3 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 switch config aggregator group 1...

Страница 88: ...02 1QVLAN vlan 8021q name GroupName vid VID V Change the name ofVLAN group if the group didn t exist this command can t be applied switch vlan vlan 8021q name test vid 22 vlan 8021q port PortNumber access link untag UntaggedVID V Assign a access link for VLAN by port if the port belong to a trunk group this command can t be applied switch vlan vlan 8021q port 3 access link untag 33 vlan 8021q port...

Страница 89: ...vlan vlan 8021q trunk 3 trunk link tag 2 3 6 99 or switch vlan vlan 8021q trunk 3 trunk link tag 3 20 vlan 8021q trunk PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by trunk group switch vlan vlan 8021q trunk 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q trunk 3 hybrid link untag 5 tag 6 8 show vlan GroupID or show vlan V ShowVLAN informati...

Страница 90: ...5 spanning tree hello time seconds G Use the spanning tree hello time global configuration command to specify the interval between hello bridge protocol data units BPDUs switch config spanning tree hello time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time...

Страница 91: ...ty on this interface switch config interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge True False I Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin edge True stp admin non stp True False I Admin NonSTP of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin non stp Fal...

Страница 92: ...witch config qos prioritytype qos priority portbased Port lowest low middle high G Configure Port based Priority switch config qos priority portbased 1 low qos priority cos Priority lowest low middle high G Configure COS Priority switch config qos priority cos 0 middle qos priority tos Priority lowest low middle high G Configure TOS Priority switch config qos priority tos 3 high show qos P Display...

Страница 93: ...t IGMP query to force mode switch config Igmp query force igmp unregister flooding G Set unregister stream flooding switch config igmp unregister flooding igmp unregister blocking G Set unregister stream blocking switch config igmp unregister flooding show igmp configuration P Displays the details of an IGMP configuration switch show igmp configuration no igmp G Disable IGMP snooping function swit...

Страница 94: ...f interface static switch config interface fastEthernet 2 switch config if no mac address table static hwaddr 000012345678 no mac address table filter hwaddr MAC G Remove an entry of MAC address table filter switch config no mac address table filter hwaddr 000012348678 no mac address table G Remove dynamic entry of MAC address table switch config no mac address table Multicast Filtering Commands S...

Страница 95: ...unity string trap version v1 v2c G Configure SNMP server host information and community string switch config snmp server host 192 168 1 50 community public trap version v1 remove Switch config no snmp server host 192 168 1 50 snmpv3 context name Context Name G Configure the context name switch config snmpv3 context name Test snmpv3 user User Name group Group Name password Authentication Password P...

Страница 96: ...o snmp server host 192 168 1 50 no snmpv3 user User Name G Remove specified user of SNMPv3 agent switch config no snmpv3 user Test no snmpv3 access context name Context Name group Group Name security level NoAuthNoPriv Auth NoPriv AuthPriv match rule Exact Prifix views ReadView Name WriteView Name NotifyView Name G Remove specified access table of SNMPv3 agent switch config no snmpv3 access contex...

Страница 97: ... G Set RX destination port of monitor function switch config monitor rx 2 monitor tx Port ID G Set TX destination port of monitor function switch config monitor tx 3 show monitor P Show port monitor information switch show monitor show monitor I Show port monitor information switch config interface fastEthernet 2 switch config if show monitor no monitor I Disable source port of monitor function sw...

Страница 98: ... sharedkey ID G Use the 802 1x system share key global configuration command to change the shared key value switch config 8021x system sharedkey 123456 8021x system nasid words G Use the 802 1x system nasid global configuration command to change the NAS ID switch config 8021x system nasid test1 8021x misc quietperiod sec G Use the 802 1x misc quiet period global configuration command to specify th...

Страница 99: ...iguration command to set the reauth period switch config 8021x misc reauthperiod 3000 8021x portstate disable reject accept authorize I Use the 802 1x port state interface configuration command to set the state of the selected port switch config interface fastethernet 3 switch config if 8021x portstate accept show 8021x E Displays a summary of the 802 1x properties and also the port sates switch s...

Страница 100: ...r and the file name of image switch config backup flash backup_cfg restore flash restore_cfg G Get configuration from TFTP server and need to specify the IP of TFTP server and the file name of image switch config restore flash restore_cfg upgrade flash upgrade_fw G Upgrade firmware by TFTP and need to specify the IP of TFTP server and the file name of image switch config upgrade flash upgrade_fw ...

Страница 101: ...hentication account switch config smtp account John smtp password password G Configure authentication password switch config smtp password 1234 smtp rcptemail Index Email address G Configure Rcpt e mail Address switch config smtp rcptemail 1 Alert test com show smtp P Show the information of SMTP switch show smtp no smtp G Disable SMTP function switch config no smtp event device cold start Systeml...

Страница 102: ...face fastethernet 3 switch config if no event systemlog no event smpt I Disable port event for SMTP switch config interface fastethernet 3 switch config if no event smtp show systemlog P Show system log client server information switch show systemlog Fault Relay Alarm Commands Set AlliedT elesis Commands Level Description Example faultrelay power G Configure Relay Alarm for Power Failure switch co...

Страница 103: ... Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP G Set SNTP server IP if SNTP function is inactive this command can t be applied switch config sntp ip 192 169 1 1 sntp timezone Timezone G Set timezone index use show sntp timzezone command to get more information of index number switch config sntp timezone...

Страница 104: ... switch config ring ringport 7 8 ring couplingport Coupling Port G Configure Coupling Port switch config ring couplingport 1 ring controlport Control Port G Configure Control Port switch config ring controlport 2 ring homingport Dual Homing Port G Configure Dual Homing Port switch config ring homingport 3 show ring P Show the information of X Ring switch show ring no ring G Disable X ring switch c...

Страница 105: ... system Capacitive Detection switch poe system capacitive detect enable port PortNumbers state Enable Disable P Set PoE port State switch poe port 1 state disable port PortNumbers plfc Enable Disable P Set PoE port Power Limit from Classification switch poe port 1 plfc enable port PortNumbers legacy Enable Disable P Set PoE port Legacy switch poe port 1 legacy enable port PortNumbers priority Low ...

Отзывы: