AT-9800 Series Switch

C613-03059-00 REV F

Gigabit Interface Converters (GBICs)

GBICs are removable gigabit port converters for switches that have GBIC bays. 
GBICs allow users to interchange port types to meet changing network 
requirements. GBICs can be purchased when a switch is purchased, or can be 
purchased separately as needed.

The following GBICs have been tested and approved for use with AT-9800 
Series switches:

Allied Telesis AT-G8T, 1000BASE-T, 100m

Allied Telesis AT-G8SX, 550m SX

Allied Telesis AT-G8LX10, 10km LX

Allied Telesis AT-G8LX25, 25km LX

Allied Telesis AT-G8LX40, 40km LX

Allied Telesis AT-G8LX70, 70km LX

For the latest list of approved GBICs, contact your authorised Allied Telesis 
distributor or reseller, or visit 

www.alliedtelesis.com/support/software

.

For information on installing GBICs, see the AT-9800 Series Switch Quick 
Install Guide.

Any combination of copper and fibre GBICs can be installed in the AT-9812T 
and AT-9816GB switches.

Important

RX and TX terminal locations on SC fibre GBIC ports are the reverse 

of RX and TX terminal locations on fixed SC fibre ports. When looking at an SC 
fibre GBIC from the front, the RX terminal is on the left and the TX terminal is 
on the right.

GBIC 1000BASE-T Auto-Negotiation

1000BASE-T GBICs support only 1000 Mbps full duplex connections. Although 
1000BASE-T GBICs will participate in auto-negotiation processes, they will 
only advertise 1000 Mbps. Half duplex, 10BASE-T, and 100BASE-TX modes are 
not supported.

While 1000BASE-T GBICs will auto-negotiate at the copper Ethernet level, the 
ports will behave as if in fixed 1000 Mbps full duplex mode. This is because the 
SERDES connection used by GBIC ports makes the auto-negotiation invisible 
to the switch, and so prevents a successful link negotiation.

When a 1000BASE-T GBIC is inserted into a GBIC slot, the port’s auto-
negotiation capability is disabled. This means that the port speed may not be 
set to "auto-negotiate". If the port has been configured to auto-negotiate (by 
default or by command) prior to the GBIC’s insertion, then this configuration is 
overridden for as long as the GBIC remains in place.

Содержание AT-9812T V2

Страница 1: ...AT 9800 Series Switch Hardware Reference AT 9812TV2 AT 9816GBV2 AT RPS9000 AT PWR9000...

Страница 2: ...notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever inclu...

Страница 3: ...232 Terminal and Modem Cables 14 Cables for RJ 45 Ethernet LAN Interfaces 15 Cable Guidelines 16 Redundant Power Supply RPS 17 AT RPS9000 Specifications 18 AT TFTP Server 19 Using Windows Terminal an...

Страница 4: ...rdware expansion options such as CompactFlash CAM and DIMM the AT 9800 Series is a versatile and powerful switching solution for rapidly evolving networks Dimensions Height 66mm plus 5 5 mm if the rub...

Страница 5: ...ble expansion of flash up to 512MBytes 512kBytes of Non volatile SRAM NVRAM Battery backed real time clock RTC 32 66MHz PCI bus Silicon ID chip storing serial number board ID and MAC address Asynchron...

Страница 6: ...A D C L A GBIC L A GBIC ASYN0 1000BASE X GBIC 10BASE T 100BASE TX 1000BASE T ACT 1000M L A ACT 10 100M COL FULL DUP HALF DUP D C FAULT ACT LINK FULL DUP L A ACT LINK HALF DUP DISABLED ENABLED GBIC GB...

Страница 7: ...re sensor located immediately adjacent to the switch chip has exceeded the recommended threshold of 60 degrees Celsius RPS Redundant Power Supply Green An RPS is connected to the switch and is receivi...

Страница 8: ...ion GBIC L A Link activity Green A 1000 Mbps link is open The link is operating in full duplex mode Flashing green 1000 Mbps full duplex activity is occurring Amber A 1000 Mbps link is open The link i...

Страница 9: ...from a remote location via a modem connection You can also use ASYN0 to establish a network connection from a remote site using SLIP and a modem ASYN0 has a DCE female socket This allows the use of a...

Страница 10: ...portant RX and TX terminal locations on SC fibre GBIC ports are the reverse of RX and TX terminal locations on fixed SC fibre ports When looking at an SC fibre GBIC from the front the RX terminal is o...

Страница 11: ...mpactFlash card AT CF128A 00 128MB CompactFlash card For the latest list of approved CompactFlash cards contact your authorised Allied Telesis distributor or reseller or visit www alliedtelesis com su...

Страница 12: ...cflash test command The test software will read the file allocation table and display a list of free sectors Sectors can be tested as single sectors or as a range The test will consist of a write read...

Страница 13: ...L2 L3 tables LineCAM can be ordered as a pre installed item when purchasing a switch or can be purchased separately For more information contact your authorised Allied Telesis distributor or reseller...

Страница 14: ...32 DB9 male to male modem cable Figures in this section show pin wiring diagrams to connect a standard VT100 compatible terminal or modem to ASYN0 RS 232 DB9 male to female terminal cable Notes 1 Outp...

Страница 15: ...r cables with RJ 45 connectors Pin assignments Each pair of twisted pair cables is identified by related colours For example one wire might be red and the related wire would be red and white stripe An...

Страница 16: ...RJ 45 four pair cross over cable Cable Guidelines The following table lists port connector and cable combinations for AT 9800 Series switches and GBICs 1 Refer to the IEEE 802 3 standards for further...

Страница 17: ...pport up to four switches The AT RPS9000 chassis has two AC power inlets Each inlet supplies two bays and therefore two AT PWR9000 units and two switches Rear panel of the AT RPS9000 The pin layout an...

Страница 18: ...ction fault located on AT 9800 Series switches RPS is supplying power to switch located on AT 9800 Series switches For LED descriptions see Switch LEDs on page 7 Controls Individual power switch for e...

Страница 19: ...field specifies the directory that AT TFTP Server will read from or write to for file requests that do not include a directory specification To prevent unauthorised access to private directories enter...

Страница 20: ...allations HyperTerminal is available from the Communications submenu The key to successful use of terminal emulation software with the switch is to configure the software and switch with matching comm...

Страница 21: ...EV F 3 In the Connect using field on the Connect To dialog box select the COM port on the PC used to connect to the switch and click the OK button 4 In the COMn Properties dialog box set port paramete...

Страница 22: ...Settings tab and set the Properties dialog box as follows 6 Click ASCII Setup to display the ASCII Setup dialog box and ensure the following options are not selected Echo typed characters locally Appe...

Страница 23: ...YN0 A terminal cable suitable for use with ASYN0 is supplied with each switch Using the supplied terminal cable or a cable you have made by following the instructions in Cables on page 14 connect your...

Страница 24: ...elp topic You can also type a question mark at the end of a partially completed command to see a list of valid options Startup Procedure When the switch starts up following either a power cycle or an...

Страница 25: ...perate FAIL An error message that a fatal error condition has caused the system to halt in an unrecoverable fashion Message Description INFO Self tests beginning Code loader tests are about to begin I...

Страница 26: ...displayed amount of memory was found This amount is less than the minimum required to run the switch software INFO Self tests complete The startup tests have finished INFO Downloading switch software...

Страница 27: ...ested Test results are displayed using the command show test The following figure shows typical output from the show test command A more detailed output with frame counts can be displayed using the co...

Страница 28: ...P1 0 42029694 Duration Frame Counters Interface State Type minutes Tx RxTotal RxGood RxBad port1 testing TP 1 000298842 000298841 000298841 000000000 port2 no test port3 no test port4 testing TP 1 00...

Страница 29: ...edWare Operating System Software Reference for more information about obtaining the latest software release 7 If the switch is malfunctioning reboot it by pressing the recessed RESET button or enterin...

Страница 30: ...Fault LED is on This can indicate there is a problem with the switch or PSU the switch or management software is malfunctioning a hardware fault is preventing switch startup Perform the following step...

Страница 31: ...use danger of injury from electric shock damage to the switch and invalidation of the product warranty To install LineCAM in an AT 9800 series switch 1 Avoid injury by working in a safe environment Th...

Страница 32: ...d with the holes on the CAM and the CAM s chamfers should be pointing to the switch s PSU 8 Insert the CAM Warning Forcing a misaligned CAM will damage the CAM s connector and CAM slot Press the CAM f...

Страница 33: ...e CAM alignment and insertion steps Use the show switch command again and if the display is still not correct contact your authorised Allied Telesis distributor or reseller Important If any CAM test f...

Страница 34: ...ore removing the switch s lid the power cord and if connected RPS power cord should be disconnected to reduce risk of electrical shock 4 Remove all interface cables 5 Remove the switch s lid The switc...

Страница 35: ...figure Insert the DIMM into the DIMM slot sliding it along the two DIMM guides until the retaining latches automatically click into place The latches should hold the DIMM firmly in place Testing DIMM...

Страница 36: ...the serial numbers of both the base card on the switch and the DIMM The switch s serial numbers and revision details can be read using the show system command It s a good idea to record this informat...

Страница 37: ...0 Using a terminal cable connect a terminal to the RS 232 port ASYN0 on the switch See Cables on page 14 for more information on terminal cables Set the terminal communication parameters to the follow...

Страница 38: ...T 9800 Series Statutory and Safety Information booklet which includes important safety information and statutory declarations for AT 9800 Series switches The AT RPS9000 Statutory and Safety Informatio...

Страница 39: ...ocument toolbar buttons such as the Next Page button keyboard shortcuts such as arrow keys commands from the Document menu mouse wheel To go to a specific section or topic click a bookmark thumbnail o...

Отзывы: